The USDA-FSIS has zero tolerance for E. coli O157:H7 in raw ground beef. Currently, FSIS collects samples from beef processing facilities and ships them overnight to regional testing laboratories. Pathogen detection requires robust methods that employ an initial 15–24 h culture enrichment. This study assessed the potential of using the ΦV10nluc phage-based luminescence detection assay during enrichment while the sample is in transit. Parameters including phage concentrations, temperature, and media-to-sample ratios were evaluated. Results in liquid media showed that 1.73× 103 pfu/mL of ΦV10nluc was able to detect 2 CFU in 10 h. The detection of E. coli O157:H7 was further evaluated in kinetic studies using ratios of 1:3, 1:2, and 1:1 ground beef sample to enrichment media, yielding positive results for as little as 2–3 CFU in 325 g ground beef in about 15 h at 37 °C. These results suggest that this approach is feasible, allowing the detection of a presumptive positive upon arrival of the sample to the testing lab. As the current cargo hold controlled temperature is required to be 15–25 °C, the need for elevated temperature should be easily addressed. If successful, this approach could be expanded to other pathogens and foods.
Food spoilage and the associated organisms are a continuing concern for the food industry. The microorganisms involved with food spoilage in pasteurized milk can be introduced in a variety of ways, which include those that survive pasteurization and/or are introduced post-pasteurization. The use of bacteriophages for therapeutic regimens and as a method for the biocontrol of food-borne pathogens has been widely studied and applied; however, their use in the biocontrol against spoilage organisms is in its nascency. Bioluminescent bacteria offer the ability to act as cell-death reporters. In the case of using bacteriophage against spoilage-associated bacteria, cell death results in the loss of bioluminescence. In this study, a bioluminescent Pseudomonas species, Pseudomonas fluorescens M3A, was used to monitor the efficacy of the bacteriophage-associated biocontrol system within laboratory bacterial growth broth and fluid milk using bacteriophage ΦS1. Utilizing a bioluminescence kinetic assay with ten-fold serially diluted P. fluorescens M3A and bacteriophage ΦS1, data demonstrated rapid inactivation of bacterial growth, and at low bacteriophage titers. Cell death was indicated by the loss of bacterial bioluminescence. These data help to support the application of bacteriophage-based technologies against spoilage-associated bacteria to prolong shelf life in the event of microbial growth.
Bioluminescent bioreporters are widely used across various scientific disciplines due to the well-characterized bacterial bioluminescence mechanism. However, solvent-induced membrane perturbations may confound the use of bioreporters in assessing cellular toxicity from environmental contaminants. This study investigated the solvent effect, wherein membrane damage increases intracellular availability of bioluminescent reaction precursors, increasing the light produced. A new online in situ monitoring system was also tested with multiple bioluminescent reporters, including a newly constructed Pseudomonas fluorescens M3A strain, exposed to toluene, trichloroethylene, acetone, phenol and creosote derived from beechwood tar. Additional tests included the introduction of carbon nanotubes, fullerene and fullerenol. A solvent effect was confirmed by the detection of increased bioluminescent signal and the occurrence of fatty acid release ( P 0.05). These results indicate that P. fluorescens M3A is a sensitive biosensor for detecting environmental contaminants and identifying both lethal and sublethal membrane perturbations. The findings underscore essential considerations when utilizing bacterial bioluminescence as a proxy for gene expression or cellular physiology.