Supawud Nedphokaew

Dr. Supawud Nedphokaew

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2024 in Energies
Verified
Journal Article
Open access
PDF file
NRNattachote Rugthaicharoencheep
Nattachote Rugthaicharoencheep
NRNatchapol Ruangsap
Natchapol Ruangsap
SNSupawud Nedphokaew
Supawud Nedphokaew
This paper presents an analysis of shortening the payback period of greenhouse gas reduction benefits from photovoltaic rooftop systems. The objective was to evaluate the amount of carbon credits generated and their returns. The study includes an economic analysis and a comparison of the economic outcomes with and without the consideration of carbon credits from 149.80 kWp and 25.68 kWp photovoltaic rooftop systems. The study evaluated the amount of electrical energy produced by the photovoltaic rooftop systems, estimated using the PVsyst program version 7.3.1, at a factory in Pathum Thani Province, Thailand. The economic indices analyzed in this study include the payback period, net present value (NPV), benefit–cost ratio (B/C ratio), and internal rate of return (IRR). The analysis is divided into four case studies: Case 1 is the base case, and Cases 2, 3, and 4 consider carbon credits for 7, 14, and 25 years, respectively. The economic indices analyzed in Case 1 include the financial internal rate of return (FIRR), payback period, financial net present value (FNPV), and B/C ratio. In Cases 2, 3, and 4, the economic indices analyzed are the economic internal rate of return (EIRR), the economic net present value (ENPV), the B/C ratio, and the payback period. This paper outlines a new economic calculation approach that incorporates carbon credits produced by photovoltaic rooftop systems, which helps achieve break-even points more quickly. It also discusses the application of carbon credits in conjunction with renewable energy.

15 February 2025 in Energies
Verified
Journal Article
Open access
PDF file
NKNitikorn Kesphrom
Nitikorn Kesphrom
SNSupawud Nedphokaew
Supawud Nedphokaew
NRNatchapol Ruangsap
Natchapol Ruangsap
NRNattachote Rugthaicharoencheep
Nattachote Rugthaicharoencheep
This research article presents a method for selecting an improvement approach for the power distribution system by analyzing financial losses caused by faults in the system. These losses can be in two parts: the first part arises from power outages, which lead to lost sales, estimated opportunities, and expenses for resolving the outages, while the second part results from voltage sags that affect sensitive electrical equipment. The method involves simulating faults at various points in the distribution system and assessing their impact on industrial, commercial, and large-scale electricity consumers. The results demonstrate that by combining the total financial losses from both parts and comparing these losses before and after implementing system improvements, effective and economically viable decision-making information can be obtained for enhancing the power distribution system.

14 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
NRNattachote Rugthaicharoencheep
Nattachote Rugthaicharoencheep
SNSupawud Nedphokaew
Supawud Nedphokaew
This research aims to present a study of the effects of the Tesla transformer in order to find the proper dimensions. We created a design of the Tesla transformer to reduce the high-voltage electric field-stress problem that happens between primary winding and secondary winding. Because the Tesla transformer is used to induce voltage between these two windings through the air, problems with insulation occur. The winding that has space is dielectric; while there is high voltage in a transformer, it causes flashover voltage between the high-voltage winding and low-voltage winding, which damages the transformer and other devices. Research process: Research was conducted to study the laydown model (positioning) of the two windings in the transformer. By considering this, we induced a proper Tesla transformer that was reproduced by using the FEMLAB program. Moreover, we compared the Tesla transformer reproduction, which created a voltage of 120 kV and a frequency of 120 kHz. The result from the comparison is a proper laydown position of the primary winding and voltage, which has been designed without the flashover. The whorl coil has to be wound at a 60-degree angle relative to the floor and can induce more voltage than other models. The voltage and corresponding electric field stress were measured for the primary winding at various angles relative to the floor (0-, 30-, 45-, 60-, and 90-degree angles) to determine the configuration. The results from the reproduction using the FEMLAB program and testing demonstrated that no flashover occurred between the high-voltage winding to the low-voltage winding when the primary winding was positioned at a 60-degree angle.

25 October 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
NRNattachote Rugthaicharoencheep
Nattachote Rugthaicharoencheep
NRNatchapol Ruangsap
Natchapol Ruangsap
SNSupawud Nedphokaew
Supawud Nedphokaew
This paper presents shortening the payback period of greenhouse gas reduction benefits from photovoltaic rooftop system. The objective was to evaluate the amount and returns of carbon credits. Economic analysis, and comparison of economic analysis with and without consideration of carbon credits from a 149.80 kWp, and 25.68 kWp photovoltaic rooftop system. This study evaluated the amount of electrical energy produced by a photovoltaic rooftop system estimated from the PVsyst program of the factory in Pathum Thani Province, Thailand. The economic indices that the researcher analyzed include the payback period, net present value (NPV), benefit cost ratio (B/C ratio), internal rate of return (IRR). It is divided into four cases studies: Case 1 is the base case, and Cases 2, 3, and 4 are considered carbon credits for 7, 14, and 25 years, respectively. The economic indices analyzed in Case 1 include financial internal rate of return (FIRR), payback period, financial net present value (FNPV), and B/C ratio. The economic indices analyzed in Cases 2, 3, and 4 are the economic internal rate of return (EIRR), economic net present value (ENPV), B/C ratio, payback periods, respectively. This paper outlines a new economic calculation approach that considers carbon credits produced by photovoltaic rooftop system to reach break-even points more quickly, and the application of carbon credits in conjunction with renewable energy.

6 April 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SNSupawud Nedphokaew
Supawud Nedphokaew
PKPakawat Kerpasit
Pakawat Kerpasit
PWPoonsri Wannakarn
Poonsri Wannakarn
NRNatchapol Ruangsap
Natchapol Ruangsap
NRNattachote Rugthaicharoencheep
Nattachote Rugthaicharoencheep
This paper presents the application of ozone for pest control in large-scale systems, with the potential for industrial implementation. The designed ozone generation system is capable of producing an ozone concentration of 550 ppm within 30 min in a controlled chamber. Ozone technology was applied for the control of insect pests in the orchid export industry, both for current use and future applications. A high-concentration ozone generator was designed to operate at temperatures ranging from 30 to 35 degrees Celsius. The total operating time of the system was 90 min, with a power consumption of 2647 watts. Experimental results indicated that the orchids were not adversely affected by the ozone exposure and that no chemical residues remained after treatment. Furthermore, the research evaluated the effectiveness of ozone fumigation against common orchid pests, namely aphids and red spider mites. When exposed to ozone concentrations ranging from 550 to 650 ppm for 60 min, the system achieved a 100% pest elimination rate for both species. These findings suggest that ozone treatment is a promising alternative to chemical pesticides for pest control in the orchid industry.

25 November 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
NRNattachote Rugthaicharoencheep
Nattachote Rugthaicharoencheep
SNSupawud Nedphokaew
Supawud Nedphokaew
This paper present analysis of electric field distribution on windings of primary side of high frequency, and voltage transformers with variables characteristics. To study the effect of high transformer voltage, induce and high frequency for finding suitable dimension. The objective is analysis of electricity field distribution at the low voltage at the angle 0, 30, 45, 60, and 90 degrees, Comparing voltage flow out of the putting primary coil. Comparing external frequency of primary coil putting. Comparing result of distribution electricity field model between primary coil (Lp) and secondary coil. By consideration from induce that proper for Tesla transformer reproduce by using FEMLAB program. Comparing the Tesla transformer reproduce which is created the frequency 120 kHz and voltage at 120 kV. Analysis use FEMLAB program. The result isn’t flash over between the low and high voltage winding.