Vincenza Notaro

Vincenza Notaro

Auto-generated profile, based on publicly available information

Vincenza Notaro


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2010 in Water Science & Technology
Verified
Journal Article
Closed access
Gabriele FreniGabriele Freni
Gabriele Freni
GLG. La Loggia
G. La Loggia
VNV. Notaro
V. Notaro
Due to the increased occurrence of flooding events in urban areas, many procedures for flood damage quantification have been defined in recent decades. The lack of large databases in most cases is overcome by combining the output of urban drainage models and damage curves linking flooding to expected damage. The application of advanced hydraulic models as diagnostic, design and decision-making support tools has become a standard practice in hydraulic research and application. Flooding damage functions are usually evaluated by a priori estimation of potential damage (based on the value of exposed goods) or by interpolating real damage data (recorded during historical flooding events). Hydraulic models have undergone continuous advancements, pushed forward by increasing computer capacity. The details of the flooding propagation process on the surface and the details of the interconnections between underground and surface drainage systems have been studied extensively in recent years, resulting in progressively more reliable models. The same level of was advancement has not been reached with regard to damage curves, for which improvements are highly connected to data availability; this remains the main bottleneck in the expected flooding damage estimation. Such functions are usually affected by significant uncertainty intrinsically related to the collected data and to the simplified structure of the adopted functional relationships. The present paper aimed to evaluate this uncertainty by comparing the intrinsic uncertainty connected to the construction of the damage-depth function to the hydraulic model uncertainty. In this way, the paper sought to evaluate the role of hydraulic model detail level in the wider context of flood damage estimation. This paper demonstrated that the use of detailed hydraulic models might not be justified because of the higher computational cost and the significant uncertainty in damage estimation curves. This uncertainty occurs mainly because a large part of the total uncertainty is dependent on depth-damage curves. Improving the estimation of these curves may provide better results in term of uncertainty reduction than the adoption of detailed hydraulic models.

25 November 2010 in Urban Water Journal
Verified
Journal Article
Closed access
Mauro De MarchisMauro De Marchis
Mauro De Marchis
CFC. M. Fontanazza
C. M. Fontanazza
Gabriele FreniGabriele Freni
Gabriele Freni
GLG. La Loggia
G. La Loggia
ENEnrico Napoli
Enrico Napoli
VNV. Notaro
V. Notaro
In many countries, private tanks are acquired by users to reduce their vulnerability to intermittent supply. The presence of these local reservoirs modifies the user demand pattern and usually increases user water demand at the beginning of the service period depending on the tank filling process. This practice is thus responsible for the inequality that occurs among users: those located in advantaged positions of the network are able to obtain water resources soon after the service period begins, while disadvantaged users have to wait much longer, after the network is full. This dynamic process requires the development of ad hoc models in order to obtain reliable results. This paper discusses a numerical model used for evaluating this complex process as well as the application of model to an Italian case study. The model agreed with calibration data and provided interesting insights into the network filling process.

1 January 2015 in Procedia Engineering
Verified
Journal Article
Open access
CFChiara M. Fontanazza
Chiara M. Fontanazza
VNVincenza Notaro
Vincenza Notaro
VPValeria Puleo
Valeria Puleo
PNPaolo Nicolosi
Paolo Nicolosi
Gabriele FreniGabriele Freni
Gabriele Freni
This paper presents the results of experimental tests on the intrusion of contaminant through pipe cracks in water distribution network resulting from low/negative pressures. The tests were carried out on a looped distribution network at the University of Enna and were performed first producing a pressure transient that causes negative pressures then reproducing intermittent supply. A soluble contaminant was added to the water volume in the network through a pipe crack. Sampling of water volume was carried out in two nodes of the network and the contaminant concentrations were measured. It was showed that: the contaminant was drawn in and transported, in the first set of tests; the contaminant was carried through the network to the point-of-use when the pipes become completely full and the distribution system was in steady state conditions, in the second, and that the concentrations was higher than in the first set of tests

1 January 2014 in Procedia Engineering
Verified
Journal Article
Open access
Mauro De MarchisMauro De Marchis
Mauro De Marchis
CFC.M. Fontanazza
C.M. Fontanazza
Gabriele FreniGabriele Freni
Gabriele Freni
Antonio MessineoAntonio Messineo
Antonio Messineo
BMB. Milici
B. Milici
ASA. Scopa
A. Scopa
In complex networks characterized by the presence of private tanks, water managers usually apply intermittent distribution, thus reducing the water volumes supplied to the users, or use Pressure Reduction Valves (PRV) for controlling pressure in the network. The application of Pump As Turbines (PATs) appears as an alternative and sustainable solution to either control network pressure as well as to produce energy. In the present paper, the hydrodynamic model, already presented by De Marchis et al. (2011) was further developed introducing the dynamic analysis of PATs. The model was applied to a district of Palermo network (Italy) characterized by intermittent distribution and by inequities among the user in term of water supply

22 December 2010 in Journal of Hydroinformatics
Verified
Journal Article
Closed access
Mauro De MarchisMauro De Marchis
Mauro De Marchis
CFC. M. Fontanazza
C. M. Fontanazza
Gabriele FreniGabriele Freni
Gabriele Freni
GLG. La Loggia
G. La Loggia
ENEnrico Napoli
Enrico Napoli
VNV. Notaro
V. Notaro
In many countries, users acquire private tanks to reduce their vulnerability to water scarcity. In such conditions, water managers often apply intermittent distribution in order to reduce the water volumes supplied to the users. This practice modifies the hydraulic behaviour of the network and determines competition among users that need to collect enough water resource for their uses. Intermittent distribution is thus responsible for the inequality that can occur among users: those located in advantaged positions of the network are able to obtain water resources soon after the service period begins, while others have to wait much longer, after the network is full. This paper analyses the inequalities that take part when intermittent distribution is applied in water scarcity scenarios. Considering the complexity of the process, the analysis was performed by means of an unsteady numerical model. The model was applied to a real case study which provided interesting insights into the network filling process, helping to highlight the advantaged and disadvantaged areas of the network in different water scarcity scenarios.

8 January 2016 in Water
Verified
Journal Article
Open access
PDF file
Lorena LiuzzoLorena Liuzzo
Lorena Liuzzo
VNVincenza Notaro
Vincenza Notaro
Gabriele FreniGabriele Freni
Gabriele Freni
Rainwater harvesting (RWH) may be an effective alternative water supply solution in regions affected by water scarcity. It has recently become a particularly important option in arid and semi-arid areas (like Mediterranean basins), mostly because of its many benefits and affordable costs. This study provides an analysis of the reliability of using a rainwater harvesting system to supply water for toilet flushing and garden irrigation purposes, with reference to a single-family home in a residential area of Sicily (Southern Italy). A flushing water demand pattern was evaluated using water consumption data collected from a sample of residential customers during an extended measurement campaign. A daily water balance simulation of the rainwater storage tank was performed, and the yield-after-spillage algorithm was used to define the tank release rule. The model’s performance was evaluated using rainfall data from more than 100 different sites located throughout the Sicilian territory. This regional analysis provided annual reliability curves for the system as a function of mean annual precipitation, which have practical applications in this area of study. The uncertainty related to the regional model predictions was also assessed. A cost-benefit analysis highlighted that the implementation of a rainwater harvesting system in Sicily can provide environmental and economic advantages over traditional water supply methods. In particular, the regional analysis identified areas where the application of this system would be most effective.