1 November 2009 in Water Science & Technology
Apparent losses are usually caused by water theft, billing errors, or revenue meter under-registration. While the first two causes are directly related to water utility management and may be reduced by improving company procedures, water meter inaccuracies are considered to be the most significant and hardest to quantify. Water meter errors are amplified in networks subjected to water scarcity, where users adopt private storage tanks to cope with the intermittent water supply. The aim of this paper is to analyse the role of two variables influencing the apparent losses: water meter age and the private storage tank effect on meter performance. The study was carried out in Palermo (Italy). The impact of water meter ageing was evaluated in laboratory by testing 180 revenue meters, ranging from 0 to 45 years in age. The effects of the private water tanks were determined via field monitoring of real users and a mathematical model. This study demonstrates that the impact on apparent losses from the meter starting flow rapidly increases with meter age. Private water tanks, usually fed by a float valve, overstate meter under-registration, producing additional apparent losses between 15% and 40% for the users analysed in this study.
25 November 2010 in Urban Water Journal
In many countries, private tanks are acquired by users to reduce their vulnerability to intermittent supply. The presence of these local reservoirs modifies the user demand pattern and usually increases user water demand at the beginning of the service period depending on the tank filling process. This practice is thus responsible for the inequality that occurs among users: those located in advantaged positions of the network are able to obtain water resources soon after the service period begins, while disadvantaged users have to wait much longer, after the network is full. This dynamic process requires the development of ad hoc models in order to obtain reliable results. This paper discusses a numerical model used for evaluating this complex process as well as the application of model to an Italian case study. The model agreed with calibration data and provided interesting insights into the network filling process.
1 January 2015 in Procedia Engineering
This paper presents the results of experimental tests on the intrusion of contaminant through pipe cracks in water distribution network resulting from low/negative pressures. The tests were carried out on a looped distribution network at the University of Enna and were performed first producing a pressure transient that causes negative pressures then reproducing intermittent supply. A soluble contaminant was added to the water volume in the network through a pipe crack. Sampling of water volume was carried out in two nodes of the network and the contaminant concentrations were measured. It was showed that: the contaminant was drawn in and transported, in the first set of tests; the contaminant was carried through the network to the point-of-use when the pipes become completely full and the distribution system was in steady state conditions, in the second, and that the concentrations was higher than in the first set of tests
22 December 2010 in Journal of Hydroinformatics
In many countries, users acquire private tanks to reduce their vulnerability to water scarcity. In such conditions, water managers often apply intermittent distribution in order to reduce the water volumes supplied to the users. This practice modifies the hydraulic behaviour of the network and determines competition among users that need to collect enough water resource for their uses. Intermittent distribution is thus responsible for the inequality that can occur among users: those located in advantaged positions of the network are able to obtain water resources soon after the service period begins, while others have to wait much longer, after the network is full. This paper analyses the inequalities that take part when intermittent distribution is applied in water scarcity scenarios. Considering the complexity of the process, the analysis was performed by means of an unsteady numerical model. The model was applied to a real case study which provided interesting insights into the network filling process, helping to highlight the advantaged and disadvantaged areas of the network in different water scarcity scenarios.
19 October 2013 in Water Science & Technology
Climate change and modification of the urban environment increase the frequency and the negative effects of flooding, increasing the interest of researchers and practitioners in this topic. Usually, flood frequency analysis in urban areas is indirectly carried out by adopting advanced hydraulic models to simulate long historical rainfall series or design storms. However, their results are affected by a level of uncertainty which has been extensively investigated in recent years. A major source of uncertainty inherent to hydraulic model results is linked to the imperfect knowledge of the rainfall input data both in time and space. Several studies show that hydrological modelling in urban areas requires rainfall data with fine resolution in time and space. The present paper analyses the effect of rainfall knowledge on urban flood modelling results. A mathematical model of urban flooding propagation was applied to a real case study and the maximum efficiency conditions for the model and the uncertainty affecting the results were evaluated by means of generalised likelihood uncertainty estimation (GLUE) analysis. The added value provided by the adoption of finer temporal and spatial resolution of the rainfall was assessed.
1 January 2014 in Procedia Engineering
Flooding damage appraisal can been obtained by interpolating real damage data caused by historical flooding events or accounting the effects of a flood in terms of the depreciation of assets. Most often, the expected damage is evaluated by means of damage functions describing the relationship occurring between the damage and hydraulic characteristics of flood. The present paper aims to evaluate the uncertainty linked to the choice of the depth-damage function adopted in the flood damage analysis. Several possible depth-damage function formulations were selected in literature and applied to historical flooding events monitored in the “Centro Storico” catchment in Palermo (Italy)