Carbapenem-resistant Klebsiella pneumoniae bloodstream infection (CRKP-BSI) is a major public health threat worldwide. CRKP-BSI is associated with poor outcomes, elevated morbidity and mortality, and high healthcare costs. Therefore, the identification of risk factors for CRKP-BSI and mortality are critical for preventing and controlling CRKP in hospitals. This retrospective case-case-control study was conducted at General Hospital of Tianjin Medical University, a tertiary teaching hospital, from 2017 to 2023. It included 105 patients with CRKP-BSI (case group 1) and matched 105 patients with carbapenem-susceptible K. pneumoniae bloodstream infection (CSKP-BSI) (case group 2). The control group was selected at a ratio of 1:1:1 (case group 1: case group 2: control) from patients with a positive blood culture (except for K. pneumoniae infection) to analyze risk factors associated with the two case groups and compare the 30-day survival curves using multivariable logistic regression and Kaplan-Meier analyses. Multivariate analysis revealed that liver disease was a risk factor for K. pneumoniae-BSI, and exposure to carbapenem [odds ratio (OR) = 3.24], tigecycline (OR = 3.43), and glucocorticoids (OR = 4.64) were independent risk factors for CRKP-BSI. The 30-day mortality of the CRKP-BSI group was 30.5%, and patient groups, respiratory diseases (HR = 3.52), use of 3rd-generation cephalosporins (HR = 1.92), mechanical ventilation (HR = 2.14), and central venous catheter insertion (HR = 2.85) were independent risk factors, whereas a shorter length of hospitalization was a protective factor for 30-day mortality. The in-hospital mortality in the CRKP-BSI group was 55.2%, and arterial catheter use (OR = 3.76) was an independent risk factor for in-hospital mortality. Several factors were identified to contribute to the development of CRKP-BSI. CRKP isolates were resistant to most antibiotics. Reducing CRKP-BSI-related mortality requires comprehensive consideration of underlying diseases, judicious antibiotic use, and invasive procedures. The high morbidity, mortality, along with the limited therapeutic options for CRKP-BSI, underscore the need for improved detection, identification of risk factors to develop effective preventive measures, and development of novel agents with reliable clinical efficacy against CRKP.
Introduction: Thyroid hormone autoantibody (THAAb) is one of the important factors affecting thyroid function measurement. By analyzing the examination of a patient suffered with Hashimoto's thyroiditis, we sought to find a correct assessment method. Material and methods: Radioimmunoassay, chemiluminescence immunoassay on an ADVIA Centaur XP system and Architect i2000sr platform, and electrochemiluminescence immunoassay on a Roche Cobas 601 system were used for detecting thyroid function. Polyethylene glycol (PEG) precipitation were performed to eliminate the influence of THAAbs. Results: The results showed that the patient’s thyroid function was consistent with the clinical manifestations and conformed to the law of the hypothalamic-pituitary-thyroid axis at Architect-i2000sr platform and Roche-Cobas-601 system. The content of FT4 was significantly reduced and lower than the normal reference range, after the patients' serum was treated with PEG, which was in line with the clinical practice. The serum THAAb titer of the patients was nearly 100 times higher than that of the control group. Conclusions: Considering an abnormal thyroid function examination, it is necessary for laboratory staff to retest samples on different platforms. It is of great significance to provide a true and accurate result to clinicians and patients. Introduction: Thyroid hormone autoantibody (THAAb) is one of the important factors affecting thyroid function measurement. By analyzing the examination of a patient suffered with Hashimoto's thyroiditis, we sought to find a correct assessment method. Material and methods: Radioimmunoassay, chemiluminescence immunoassay on an ADVIA Centaur XP system and Architect i2000sr platform, and electrochemiluminescence immunoassay on a Roche Cobas 601 system were used for detecting thyroid function. Polyethylene glycol (PEG) precipitation were performed to eliminate the influence of THAAbs. Results: The results showed that the patient’s thyroid function was consistent with the clinical manifestations and conformed to the law of the hypothalamic-pituitary-thyroid axis at Architect-i2000sr platform and Roche-Cobas-601 system. The content of FT4 was significantly reduced and lower than the normal reference range, after the patients' serum was treated with PEG, which was in line with the clinical practice. The serum THAAb titer of the patients was nearly 100 times higher than that of the control group. Conclusions: Considering an abnormal thyroid function examination, it is necessary for laboratory staff to retest samples on different platforms. It is of great significance to provide a true and accurate result to clinicians and patients.
Hemoglobin A1c (HbA1c) can be used to evaluate blood glucose control. Its measurement will be affected by many factors, but Hb variation is the most critical factor. This study aimed to explore the types of variants found in routine work and their impact on test results. Samples with abnormal HbA1c chromatograms found in routine testing were tested with high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) and then further tested with polymerase chain reaction (PCR) and sequencing. Five recessive heterozygous mutations were identified after PCR and sequencing. Hb Riccarton-II (a mutation in the HBA2 gene), Hb E, Hb G-Coushatta, Hb G-Taipei, and Hb North Manchester (a mutation in the HbB gene) were identified. All HbA1c values of these variants detected by HLC-723 G8 (HPLC method) were lower than those of Sebia Capillarys 2 FP (C2FP, CE method) with P < .0001. Five Hb mutations were identified in our routine HbA1c test, and their HPLC detection values were significantly lower than those obtained with the CE method.
Background: Although many factors may interfere with hemoglobin (Hb)A1c measurement, Hb variants are among the most important factors. Methods: We tested the HbA1c levels of the patient, a 32 year old Manchu Chinese woman, during a routine health check. We used different methods, including high-performance liquid chromatography (HPLC) and capillary electrophoresis, to test specimens from the patient. Next, we tested the specimen further using polymerase chain reaction (PCR) and sequencing. Results: We discovered that our patient, who had an HbA1c value of 0, also has an Hb variant, Hb Long Island, which we found during the HbA1c analysis as part of her routine health check at the Health Management Center in the General Hospital of Tianjin Medical University, Tianjin, China. Also, we discovered that the exon 1 of β gene contained transversion mutations, with 1 heterozygous and 1 homozygous variant (HBB:c.8A > C, 9T > C). These gene mutations resulted in an amino-acid change (His to Pro) and a decrease in HbA1c value. Conclusions: When there is no correlation between the clinical signs, glycemic status, and glycated Hb levels of the patient, the chromatogram of HbA1c should be carefully checked to detect possible variants that cause interference in the measurement.
Acute ischemic stroke (AIS), a prevalent neurological disorder, is characterized by high incidence, disability, and mortality rates [1]. In 2020, China reported a stroke prevalence of 2.6%, an annu...