Luo Wei

Prof. Dr. Luo Wei

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 July 2021 in International Immunology
Verified
Journal Article
Open access
PDF file
JWJian Wu
Jian Wu
XZXiaowen Zhu
Xiaowen Zhu
XGXia Guo
Xia Guo
ZYZe Yang
Ze Yang
QCQinzhen Cai
Qinzhen Cai
YXYun Xiang
Yun Xiang
As a key virulence factor for persistent colonization, urease B subunit (UreB) is considered to be an ideal vaccine antigen against Helicobacter pylori infection. However, the role and molecular mechanisms of UreB involved in immune microenvironment dysregulation still remain largely unknown. In the present study, we evaluated the effects of UreB on macrophage activation and found that UreB induced PD-L1 accumulation on bone marrow-derived macrophages (BMDMs). Co-culture assays further revealed that UreB-induced PD-L1 expression on BMDMs significantly decreased the proliferation and secretion of cytolytic molecules (granzyme B and perforin) of splenic CD8+ T cells isolated from inactivated H. pylori-immunized mice. More importantly, using liquid chromatography–tandem mass spectrometry (LC-MS/MS) and co-immunoprecipitation techniques, it has been confirmed that myosin heavy chain 9 (Myh9) is a direct membrane receptor for UreB and is required for PD-L1 up-regulation on BMDMs. Molecular studies further demonstrated that the interaction between UreB and Myh9 decreased GCN2 autophosphorylation and enhanced the intracellular pool of amino acids, leading to the up-regulation of S6K phosphorylation, a commonly used marker for monitoring activation of mTORC1 signaling activity. Furthermore, blocking mTORC1 activation with its inhibitor Temsirolimus reversed the UreB-induced PD-L1 up-regulation and the subsequent inhibitory effects of BMDMs on activation of cytotoxic CD8+ T-cell responses. Overall, our data unveil a novel immunosuppressive mechanism of UreB during H. pylori infection, which may provide valuable clues for the optimization of H. pylori vaccine.

5 January 2024 in Journal of Laboratory Medicine
Verified
Journal Article
Open access
PDF file
LDLizhen Dong
Lizhen Dong
THTianqi Hao
Tianqi Hao
JCJiawei Chen
Jiawei Chen
YCYamin Chai
Yamin Chai
ZJZichao Jia
Zichao Jia
LWLuo Wei
Luo Wei
Objectives: Adrenocorticotropic hormone (ACTH) is extremely unstable and can easily degrade at room temperature. The experts agreed that the samples should be transported in an ice bath. If it cannot be detected immediately, the plasma should be separated and frozen, which is difficult to carry out in routine practice. This study was performed to explore the preanalytical factors that influence the stability of adrenocorticotrophic hormone (ACTH) measurements. Methods: ACTH levels in 21 EDTA whole-blood samples were measured immediately after 0 h and then divided into three equal groups according to the corresponding values (low, L; median, M; and high, H). Next, three sample processing methods (including seven subtypes) were used: whole blood was uncentrifuged (named the A method), stored at 4 °C or 22 °C, centrifuged but not subjected to plasma removal (the B method), stored at 4 °C or 22 °C, and centrifuged with the plasma removed and stored (the C method) at 4 °C, 22 °C, and −20 °C. Each subtype contained three samples, namely, L, M, and H; these samples were retested using a Siemens XP2000 at different times. The change bias was calculated at 0 h. Results: Compared to that at 0 h, there was no significant change in ACTH up to 24 h when the sample was stored at 4 °C or 22 °C with the B method (p>0.05), while it significantly changed (up or down >10 %) at 4 °C/24 h (bias is expressed as the mean±SEM; 13.37±21 %, p<0.05) and 22 °C/12 h (9.13±7.68 %, p<0.05) with the A method; and 4 °C/24 h (8.93±5.54 %, p<0.05), 22 °C/12 h (9.5±4.47 %, p<0.05) and −20 °C/3 h (12.03±4.8 %, p<0.05) with the C method. Conclusions: After ACTH samples were centrifuged, the presence of plasma without removal did not affect the detection value, and the sample was stored at 4 °C for up to 24 h. There was a significant difference in the detection of ATCH when the sample was stored at −20 °C and thawed again (p<0.05).

20 April 2022 in Journal of Laboratory Medicine
Verified
Journal Article
Open access
PDF file
QWQian Wang
Qian Wang
JDJin Du
Jin Du
LCLin Chen
Lin Chen
YDYu-Di Du
Yu-Di Du
LWLuo Wei
Luo Wei
Objectives: Not many reports have covered large-scale point of care testing (POCT) blood glucose comparisons, and many interfering factors affect detection. This study aims to verify the performance of POCT blood glucose meters and discusses the factors that interfere with detection. Methods: Accuracy and precision verification in five glucose concentration groups-high 1 (H1), High 2 (H2), medium 1 (M1), medium 2 (M2), and low (L); comparison of different test methods and specimens; and also the influence of iodophor was investigated in a dilution experiment. Results: A total of 58 out of 64 Accu-Chek Inform II POCT blood glucose meters (ACI II) qualified for testing. A proportional significant difference in the relative bias was observed with the POCT instruments in the intermediate and high glucose concentration groups (H=15.364, p=0.02). There were significant differences among the five groups with compliance rates (χ 2=21.03, p=0.00); Group L showed higher values than groups H1 and H2. The precision verification met the requirements issued by the Consensus. Significant differences were found between the three detection methods. The measurement of the Glucose Oxidase Method (Cobas B 123) was lower than that of the HITACHI Plasma Hexokinase Method and the Glucose Dehydrogenase Method on the ACI II (p=0.005 and 0.003) in the preliminary study. No differences were seen among the three types of specimens (p>0.05). The glucose results were incorrect in the presence of iodophor interference. Conclusions: The ACI II and Cobas B123 (with a slightly negative bias) provide sufficiently accurate measurements, and all types of blood specimens can be applied. Iodophor, a disinfectant, interferes with glucose measurement.

15 October 2022 in Laboratory Medicine
Verified
Journal Article
Closed access
PDF file
LWLuo Wei
Luo Wei
ZWZhang Weifeng
Zhang Weifeng
ZDZuoliang Dong
Zuoliang Dong
Hemoglobin A1c (HbA1c) can be used to evaluate blood glucose control. Its measurement will be affected by many factors, but Hb variation is the most critical factor. This study aimed to explore the types of variants found in routine work and their impact on test results. Samples with abnormal HbA1c chromatograms found in routine testing were tested with high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) and then further tested with polymerase chain reaction (PCR) and sequencing. Five recessive heterozygous mutations were identified after PCR and sequencing. Hb Riccarton-II (a mutation in the HBA2 gene), Hb E, Hb G-Coushatta, Hb G-Taipei, and Hb North Manchester (a mutation in the HbB gene) were identified. All HbA1c values of these variants detected by HLC-723 G8 (HPLC method) were lower than those of Sebia Capillarys 2 FP (C2FP, CE method) with P < .0001. Five Hb mutations were identified in our routine HbA1c test, and their HPLC detection values were significantly lower than those obtained with the CE method.

3 July 2025 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
CWChengxue Wang
Chengxue Wang
QWQian Wang
Qian Wang
WYWenting Yuan
Wenting Yuan
ZJZichao Jia
Zichao Jia
LDLizhen Dong
Lizhen Dong
LWLuo Wei
Luo Wei

19 August 2026 in International Journal of Neuroscience
Verified
Journal Article
Closed access
YTYin Tongtong
Yin Tongtong
WQWang Qian
Wang Qian
LZLiu Ziyi
Liu Ziyi
WCWang Chengxue
Wang Chengxue
LXLi Xiumei
Li Xiumei
LWLuo Wei
Luo Wei
Acute ischemic stroke (AIS), a prevalent neurological disorder, is characterized by high incidence, disability, and mortality rates [1]. In 2020, China reported a stroke prevalence of 2.6%, an annu...