Inaccuracies from devices for non-invasive blood pressure measurements have been well reported with clinical consequences. International standards, such as ISO 81060-2 and the seminal AAMI/ANSI SP10, define protocols and acceptance criteria for these devices. Prior to applying these standards, a sample size of N >= 85 is mandatory, that is, the number of distinct subcjects used to calculate device inaccuracies. Often, it is not possible to gather such a large sample. Many studies apply these standards with a smaller sample. The objective of the paper is to introduce a methodology that broadens the method first developed by the AAMI Sphygmomanometer Committee for accepting a blood pressure measurement device. We study changes in the acceptance region for various sample sizes using the sampling distribution for proportions and introduce a methodology for estimating the exact probability of the acceptance of a device. This enables the comparison of the accuracies of existing device development techniques even if they were studied with a smaller sample size. The study is useful in assisting BP measurement device manufacturers. To assist clinicians, we present a newly developed “bpAcc” package in R to evaluate acceptance statistics for various sample sizes.

14 November 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TCTanvi Chandel
Tanvi Chandel
VSVictor Miranda Soberanis
Victor Miranda Soberanis
ALAndrew Lowe
Andrew Lowe
TLTet Chuan Lee
Tet Chuan Lee
Background/Objectives: Blood pressure (BP) readings are often rounded to the nearest zero end-digit. Guidelines permit rounding to the closest 2 mmHg. This paper investigated the effect of rounding systolic blood pressure (SBP) values on the prediction of cardiovascular disease (CVD) risk among the New Zealand population. A total of 427,299 individuals received opportunistic cardiovascular disease risk assessments at primary care facilities in New Zealand. Method: A total of 292,122 SBP readings possessed a non-zero terminal digit. These were rounded to the nearest zero end-digit. A survival model estimating a 5-year CVD risk was applied to both datasets, i.e., with and without rounding. Hazard ratios and misclassification rates were analysed to emphasise the notable differences. Financial impact was assessed by examining healthcare expenditures. Results: In total, 32% of SBP values exhibited a terminal digit of zero, and 2.85% and 4.24% of men were misclassified as moderate and high risk, respectively, while approximately 3.21% of women were misclassified into the same risk categories. Likewise, 1.19% and 0.47% of men, as well as 0.62% and 0.20% of women, were misclassified into the low and moderate risk categories, respectively. Conclusions: Precisely measuring SBP is crucial in accurately assessing CVD risk and managing healthcare resources effectively.

10 July 2025 in Journal of Human Hypertension
Verified
Journal Article
Open access
PDF file
ALAndrew Lowe
Andrew Lowe
Yang YuYang Yu
Yang Yu
TCTanvi Chandel
Tanvi Chandel
Accurate blood pressure measurement (BPM) is critical for managing hypertension, a leading global health concern. While international standards like ISO 81060-2 are applied to ensure commercial BPM device safety and effectiveness, gauging compliance earlier in research and development can be challenging. This study proposes an enhanced statistical evaluation framework that calculates a credence of device acceptability, aligned with international standards, which can be used to assess and compare results of device evaluation experiments having various sample sizes, blood pressure ranges, mean, standard deviation and correlations in error. Applied to ten studies featuring diverse BPM methods, the framework demonstrates its capability to provide insights beyond the face-value application of the performance criteria of international standards. This framework advances BPM technology by providing more appropriate tools to assess device accuracy.