Tet Chuan Lee

Dr. Tet Chuan Lee

Department of Mechanical Engineering, Auckland University of Technology, Auckland, New Zealand
+1
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2023 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
TLTet Chuan Lee
Tet Chuan Lee
AMAli Moulvi
Ali Moulvi
JJJoanna L. James
Joanna L. James
ACAlys R. Clark
Alys R. Clark
The placenta is a critical fetal exchange organ, with a complex branching tree-like structure. Its surface is covered by a single multinucleated cell, the syncytiotrophoblast, which bathes in maternal blood for most of pregnancy. Mechanosensing protein expression by the syncytiotrophoblast at term suggests that shear stress exerted by maternal blood flow may modulate placental development and function. However, it is not known how the mechanosensitive capacity of the syncytiotrophoblast, or the shear stress it experiences, change across gestation. Here, we show that the syncytiotrophoblast expresses both mechanosensitive ion channels (Piezo 1, Polycystin 2, TRPV6) and motor proteins associated with primary cilia (Dynein 1, IFT88, Kinesin 2), with higher staining for all these proteins seen in late first trimester placentae than at term. MicroCT imaging of placental tissue was then used to inform computational models of blood flow at the placentone scale (using a porous media model), and at the villous scale (using explicit flow simulations). These two models are then linked to produce a combined model that allows the variation of shear stress across both these scales simultaneously. This combined model predicts that the range of shear stress on the syncytiotrophoblast is higher in the first-trimester than at term (0.8 dyne/cm2 median stress compared to 0.04 dyne/cm2) when considering both these scales. Together, this suggests that the nature of blood flow through the intervillous space, and the resulting shear stress on the syncytiotrophoblast have important influences on placental morphogenesis and function from early in pregnancy.

3 August 2020 in WIREs Mechanisms of Disease
Verified
Journal Article
Closed access
PDF file
ACAlys Clark
Alys Clark
TLTet Chuan Lee
Tet Chuan Lee
JJJoanna L. James
Joanna L. James

10 June 2016 in Journal of Fluid Mechanics
Verified
Journal Article
Closed access
PDF file
TLTet Chuan Lee
Tet Chuan Lee
LLLong Long
Long Long
RCR. J. Clarke
R. J. Clarke
The endothelial glycocalyx layer (EGL) is a macromolecular layer that lines the inner surface of blood vessels. It is believed to serve a number of physiological functions in the microvasculature, including protection of the vessel walls from potentially harmful levels of fluid shear, as a molecular sieve that acts to regulate transendothelial mass transport, and as a transducer of mechanical stress from the vessel lumen. To best fulfil some of its roles, it has been suggested that the EGL redistributes, so that it is thickest at the cell–cell junctions. It has also been suggested that the majority of mechanotransduction occurs through the solid phase of the EGL, rather than via its fluid phase. The difficulties associated with measuring the distribution of the EGL in vivo make these hypotheses difficult to confirm experimentally. Consequently, to gauge the impact of EGL redistribution from a theoretical standpoint, we compute the flow through a porous-lined microvessel, the endothelial surface of which has been informed by confocal microscopy images of a postcapillary venule. Following earlier studies, we model the poroelastohydrodynamics of the EGL using biphasic mixture theory, taking advantage of a recently developed boundary integral representation of these equations to solve the coupled poroelastohydrodynamics using the boundary element method. However, the low permeabilities of the EGL mean that viscous effects are confined to thin layers, thereby also enabling an asymptotic treatment of the dynamics in this limit. In this asymptotic regime, we also consider a two-layer Stokes flow model for the lumen flow to approximate the effect of red blood cells within the lumen. We demonstrate that redistribution of the EGL can have a substantial impact upon microvessel haemodynamics. We also confirm that the bulk of the mechanical stress is indeed carried through the solid phase of the EGL.

25 June 2020 in Journal of Fluid Mechanics
Verified
Journal Article
Closed access
PDF file
TLTet Chuan Lee
Tet Chuan Lee
VSVinod Suresh
Vinod Suresh
RCR. J. Clarke
R. J. Clarke
The endothelial glycocalyx layer (EGL) is a brush-like layer that lines the internal surfaces of blood vessels. It is thought to serve a number of physiological functions, including as a mechanotransducer of fluid loadings to the vessel wall. However, the fragility of the EGL makes it difficult to examine experimentally, and so there is much value in theoretical models that can help to explain the dynamical behaviour of the EGL. Most previous models have employed mixture theory to mechanically describe the layer, which treats the EGL as a isotropic linearly poroelastic layer. However, there is increasing experimental evidence to suggest that the EGL has a well-defined organisational structure that might not necessarily be well captured by such mixture theory descriptions. We therefore employ homogenisation theory to incorporate into the models some of the possible EGL microstructure suggested by the current biological literature. We explore how mechanotransduction varies under the different possible EGL microstructures, which potentially has important consequences to our understanding of how structural changes to the EGL might affect a vessel's ability to respond to hemodynamical cues. We also find that, whereas mechanotransduction through the solid components of the EGL is dominated by the fluid tractions applied at the lumen-EGL interface, the component carried through its fluid phase is most sensitive to pressure gradients within the bulk EGL. This is relevant, since it is known that the underlying endothelial cells respond differently to these two different forms of mechanical loading.

25 March 2024 in Technologies
Verified
Journal Article
Open access
PDF file
TCTanvi Chandel
Tanvi Chandel
VSVictor Miranda Soberanis
Victor Miranda Soberanis
ALAndrew Lowe
Andrew Lowe
TLTet Chuan Lee
Tet Chuan Lee
Inaccuracies from devices for non-invasive blood pressure measurements have been well reported with clinical consequences. International standards, such as ISO 81060-2 and the seminal AAMI/ANSI SP10, define protocols and acceptance criteria for these devices. Prior to applying these standards, a sample size of N >= 85 is mandatory, that is, the number of distinct subcjects used to calculate device inaccuracies. Often, it is not possible to gather such a large sample. Many studies apply these standards with a smaller sample. The objective of the paper is to introduce a methodology that broadens the method first developed by the AAMI Sphygmomanometer Committee for accepting a blood pressure measurement device. We study changes in the acceptance region for various sample sizes using the sampling distribution for proportions and introduce a methodology for estimating the exact probability of the acceptance of a device. This enables the comparison of the accuracies of existing device development techniques even if they were studied with a smaller sample size. The study is useful in assisting BP measurement device manufacturers. To assist clinicians, we present a newly developed “bpAcc” package in R to evaluate acceptance statistics for various sample sizes.

3 March 2015 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
RCR. J. Clarke
R. J. Clarke
VBV. Bachtiar
V. Bachtiar
TLTet Chuan Lee
Tet Chuan Lee
John Edward CaterJohn Edward Cater
John Edward Cater
JMJ. Minton
J. Minton
The importance of hydrodynamics upon the response of a microcantilever immersed in a viscous fluid has been well established [J. E. Sader, J. Appl. Phys. 84, 64 (1998); C. A. Eysden and J. E. Sader, J. Appl. Phys. 101, 044908 (2007)]. It has previously been shown that the presence of a nearby rigid planar surface can significantly alter a microcantilever's non-contact response, through microcantilever–surface hydrodynamic interactions [C. P. Green and J. E. Sader, Phys. Fluids 17, 073102 (2005); C. P. Green and J. E. Sader, J. Appl. Phys. 98, 114913 (2005); R. J. Clarke et al., J. Fluid Mech. 545, 397426 (2005); R. J. Clarke et al., Phys. Rev. Lett. 96, 050801 (2006).]. In cases where the nearby surface is a finite-sized deformable body, such as in noncontact microrheology measurements, we expect to see further changes in the microcantilever's response. Hence, we here compute the thermal spectra of several microcantilevers in the presence of different compliant samples that have the characteristics of soft biological fibres. Our findings demonstrate that the elastohydrodynamic regime can substantially dictate the extent to which the compliance of a given body is evident in the microcantilever's thermal spectra, and suggest that certain nondimensional quantities should lie within particular, ranges for this to be the case. We expect these findings to be of interest in areas such as Atomic Force Microscopy, microsensing, and non-contact microrheology.