Venkata Ramesh Naganaboina

Dr. Venkata Ramesh Naganaboina

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2022 in ACS Applied Nano Materials
Verified
Journal Article
Closed access
VNVenkata Ramesh Naganaboina
Venkata Ramesh Naganaboina
AMAnandkumar Mariappan
Anandkumar Mariappan
ADAtul Suresh Deshpande
Atul Suresh Deshpande
SSShiv Govind Singh
Shiv Govind Singh

22 May 2023 in Chemical Physics Reviews
Verified
Journal Article
Open access
PDF file
VNVenkata Ramesh Naganaboina
Venkata Ramesh Naganaboina
SSShiv Govind Singh
Shiv Govind Singh
Gas sensors based on chemiresistive technology are attractive for their small size, low-cost fabrication, predictable electrical properties, and compatibility with electronic circuits. They have various applications from health and safety to energy efficiency and emissions monitoring. Despite exploring many gas-sensing materials to detect different gases for the above-mentioned applications, these sensors have limitations such as poor selectivity, high limit of detection, poor reversibility, high operating temperature, and poor stability that restrict their implementation in real-time applications. To address these limitations and improve the sensing performance toward target gases, various approaches have been developed. In this regard, an important aspect to improve the gas-sensing performance is to optimize the device architecture by selecting the appropriate gas-sensing material, electrode material, and electrode structure design. This review discusses the advancements in the novel gas-sensing materials, such as metal-organic frameworks (MOFs), MXenes, graphitic carbon nitride (g-C3N4), hexagonal boron nitride (h-BN), group III–VI semiconductors, phosphorene, black phosphorus, metal ferrites, and high entropy oxides. In addition, this review discusses the impact of various electrode materials, including platinum (Pt), gold (Au), silver (Ag), chromium (Cr), indium tin oxide (ITO), and aluminum (Al), and its electrode structures and design parameters on the gas-sensing performance. The electrode structures covered in this review are head-to-head, interdigitated, fractal, and laser-induced graphene. Finally, this review highlights the summary, challenges, and future perspectives of novel gas-sensing materials, electrode materials, and their structures to improve the gas-sensing performance of chemiresistive sensors.

2 November 2025 in Nanomaterials
Verified
Journal Article
Open access
PDF file
AMAnandkumar Mariappan
Anandkumar Mariappan
SSShanmugavel Sudarsan
Shanmugavel Sudarsan
VNVenkata Ramesh Naganaboina
Venkata Ramesh Naganaboina
NBNaveen Kumar Bandari
Naveen Kumar Bandari
КЛКсения Литвинюк
Ксения Литвинюк
ETEvgeny Trofimov
Evgeny Trofimov
Although fast-paced ongoing industrial growth, on the one hand, enhances the lifestyle of the population, on the other hand, it affects human health and the environment as a result of the discharge of pollutants. To address this, designing a novel and effective photocatalyst is necessary to mitigate increasing environmental pollutants. In the present work, we aim to synthesize a single-phase high-entropy zirconate pyrochlore oxide (Ce0.2Pr0.2Zn0.2Nd0.2Tb0.2)2Zr2O7 using a modified Pechini method. The physicochemical properties of the prepared nanoparticles were investigated using X-ray diffraction, UV-visible spectroscopy, field emission scanning electron microscopy, and X-ray photoelectron spectroscopy. The photocatalytic properties were examined using cationic dye (methylene blue), anionic dye (Congo red), and Cr(VI). Photocatalytic degradation experiments demonstrate exceptional efficiency in the removal of persistent organic pollutants. The photocatalytic results indicate that the prepared high-entropy (Ce0.2Pr0.2Zn0.2Nd0.2Tb0.2)2Zr2O7 zirconate pyrochlore oxide could effectively degrade dyes and reduce Cr(VI). Radical trapping experiments indicate that the degradation of dyes was driven by the hydroxyl radicals, superoxide radicals, and holes. Furthermore, the position of the valence band and conduction band promoted efficient photocatalytic reaction kinetics. The prepared photocatalyst remains structurally stable and can be reused three times without losing activity.

19 October 2022 in IEEE Electron Device Letters
Verified
Journal Article
Closed access
VNVenkata Ramesh Naganaboina
Venkata Ramesh Naganaboina
SBSatish Bonam
Satish Bonam
AMAnandkumar Mariappan
Anandkumar Mariappan
ADAtul Suresh Deshpande
Atul Suresh Deshpande
SSShiv Govind Singh
Shiv Govind Singh
Chemiresistive gas sensors (CGS) are continuously being developed over other methods for detecting gas/vapor concentrations because of their simplicity of fabrication, compatibility with conventional DC circuits and high accuracy measurement convenience. However, humidity strongly influences sensing response, while the trade-off between humidity independence and gas response is one of the major barriers to limiting CGS for practical applications. In this regard, highly selective methane (CH4) gas sensor is fabricated using Gd 0.2 La 0.2 Ce 0.2 Hf 0.2 Zr 0.2 O 2 (Ce-HEC) as a sensing material and the relative humidity (RH) effect on sensing response has been investigated. Indeed, the RH effect on the sensor response is high and can be seen in all gas concentrations at various RH levels. Therefore, humidity compensation model (HCM) is developed by fitting multivariate polynomial regression techniques to reduce the anti-interference humidity effect. HCM estimates the gas concentrations with a mean absolute percentage error of 5.81%, and a mean absolute error is 3.43 ppm. This study offers a simple and novel strategy for humidity-independent detection of gas/vapors in CGS and estimates gas concentrations with minimum error.

22 July 2025 in Results in Engineering
Verified
Journal Article
Open access
KKK. Praneeth Kumar
K. Praneeth Kumar
SISHAIK IMAMVALI
SHAIK IMAMVALI
STSreenivasulu Tupakula
Sreenivasulu Tupakula
VNVenkata Ramesh Naganaboina
Venkata Ramesh Naganaboina
SRShaik Rajak
Shaik Rajak
Pradeep Reddy GogulamudiPradeep Reddy Gogulamudi
Pradeep Reddy Gogulamudi

15 October 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
WHWon Bae Han
Won Bae Han
SHSungkeun Han
Sungkeun Han
TKTaekyung Kim
Taekyung Kim
TJTae-Min Jang
Tae-Min Jang
GKGwan-Jin Ko
Gwan-Jin Ko
SHSUKWON HWANG
SUKWON HWANG
The discovery of non-toxic, bioresorbable silicon electronics is a major breakthrough in the fields of transient, dissolvable biomedical implants and environmental monitors, as it opens up the possibility of producing versatile components based on established semiconductor processes. However, given the limited lifespan of such electronics, it is essential to consider economical manufacturing and production strategies that reduce the unit price for commercialization. Here, we introduce a solution-processable and photo-patternable approach that is facile, cost-effective, and widely accessible for a monolithic 3D fabrication of soft, stretchable, and transient electronics. Optimized chemical synthesis and rational materials engineering yield biodegradable/biocompatible organic insulators, semiconductors, and conductors that can be layered/assembled in sophisticated configurations without impairing underlying components. Direct solution-casting of the materials enables the fabrication of sensors with various modalities and transistors. In vivo implantation of soft, conformable electrode arrays into the brain and heart of animal models demonstrates spatiotemporal electrophysiological monitoring (electroencephalography and electrocardiography) and therapeutic interventions (epileptic seizure suppression and cardiac pacing), highlighting the broad applicability in diverse bio-integrated electronic systems.