Moonjin Lee

Dr. Moonjin Lee

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2018 in Sustainability
Verified
Journal Article
Open access
PDF file
Kyung-Ae ParkKyung-Ae Park
Kyung-Ae Park
JPJae-Jin Park
Jae-Jin Park
JJJae-Cheol Jang
Jae-Cheol Jang
JLJi-Hyun Lee
Ji-Hyun Lee
SOSangwoo Oh
Sangwoo Oh
MLMoonjin Lee
Moonjin Lee
The necessity of efficient monitoring of ships in coastal regions has been increasing over time. Multi-satellite observations make it possible to effectively monitor vessels. This study presents the results of ship detection methodology, applied to optical, hyperspectral, and microwave satellite images in the seas around the Korean Peninsula. Spectral matching algorithms are used to detect ships using hyperspectral images with hundreds of spectral channels and investigate the similarity between the spectra and in-situ measurements. In the case of SAR (Synthetic Aperture Radar) images, the Constant False Alarm Rate (CFAR) algorithm is used to discriminate the vessels from the backscattering coefficients of Sentinel-1B SAR and ALOS-2 PALSAR2 images. Validation results exhibited that the locations of the satellite-detected vessels showed good agreement with real-time location data within the Sentinel-1B coverage in the Korean coastal region. This study presented the probability of detection values of optical and SAR-based ship detection and discussed potential causes of the errors. This study also suggested a possibility for real-time operational use of vessel detection from multi-satellite images based on optical, hyperspectral, and SAR remote sensing, particularly in the inaccessible coastal regions off North Korea, for comprehensive coastal management and sustainability.

29 December 2017 in Sensors
Verified
Journal Article
Open access
PDF file
DSDongmin Seo
Dongmin Seo
SOSangwoo Oh
Sangwoo Oh
MLMoonjin Lee
Moonjin Lee
YHYongha Hwang
Yongha Hwang
SSSungkyu Seo
Sungkyu Seo
This paper demonstrates a commercial-level field-portable lens-free cell analyzer called the NaviCell (No-stain and Automated Versatile Innovative cell analyzer) capable of automatically analyzing cell count and viability without employing an optical microscope and reagents. Based on the lens-free shadow imaging technique, the NaviCell (162 × 135 × 138 mm3 and 1.02 kg) has the advantage of providing analysis results with improved standard deviation between measurement results, owing to its large field of view. Importantly, the cell counting and viability testing can be analyzed without the use of any reagent, thereby simplifying the measurement procedure and reducing potential errors during sample preparation. In this study, the performance of the NaviCell for cell counting and viability testing was demonstrated using 13 and six cell lines, respectively. Based on the results of the hemocytometer (de facto standard), the error rate (ER) and coefficient of variation (CV) of the NaviCell are approximately 3.27 and 2.16 times better than the commercial cell counter, respectively. The cell viability testing of the NaviCell also showed an ER and CV performance improvement of 5.09 and 1.8 times, respectively, demonstrating sufficient potential in the field of cell analysis.

1 June 2020 in Marine Pollution Bulletin
Verified
Journal Article
Closed access
MLMoonjin Lee
Moonjin Lee
Jung-Yeul JungJung-Yeul Jung
Jung-Yeul Jung
KPKi-Cheol Park
Ki-Cheol Park
SCSung-Hwan Choi
Sung-Hwan Choi

11 September 2020 in Remote Sensing
Verified
Journal Article
Open access
PDF file
JPJae-Jin Park
Jae-Jin Park
TKTae-Sung Kim
Tae-Sung Kim
Kyung-Ae ParkKyung-Ae Park
Kyung-Ae Park
SOSangwoo Oh
Sangwoo Oh
MLMoonjin Lee
Moonjin Lee
PFPierre-Yves Foucher
Pierre-Yves Foucher
As marine transportation has increased in coastal regions, maritime accidents associated with vessels have steadily increased. Remotely sensed satellite or airborne images can aid rapid vessel monitoring over wide areas at high resolutions. In this study, airborne hyperspectral experiments were performed to detect marine vessels mainly including fishing boat and yacht by applying pixel-based mixture techniques and to estimate the size of the vessels through an objective ellipse fitting method. Various spectral libraries of marine objects and seawaters were constructed through in-situ experiments for spectral analysis of the internal structures of vessels. The hyperspectral images were dimensionally reduced through principal component analysis. Several hyperspectral mixture algorithms, such as N-FINDR, pixel purity index (PPI), independent component analysis (ICA), and vertex component analysis (VCA), were used for the detection of vessels. The N-FINDR and VCA techniques presented a total of 14 vessels, the ICA technique detected seven vessels, and the PPI technique detected two vessels. The pixel-based probability of detection (POD) and false alarm ratio (FAR) for all 14 vessels were 96.40% and 4.30%, respectively. The sizes of the vessels were estimated by extracting the boundaries of the vessels through a two-dimensional gradient and applying the ellipse fitting method. Compared with the digital mapping camera (DMC) images with resolutions of 0.10 m, the root-mean-square errors of the length and width of the vessels were approximately 1.19 m and 0.81 m, respectively. The application of spectral mixing methods provided a high probability of detecting the objects, as well as the overall structures of the decks of the vessels.

31 October 2021 in Journal of the Korean Society of Marine Environment & Safety
Verified
Journal Article
Closed access
MLMoonjin Lee
Moonjin Lee
KKKyewon Kim
Kyewon Kim
WKWonsoo Kang
Wonsoo Kang

30 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JNJaeha Noh
Jaeha Noh
SASangsu An
Sangsu An
CLChanghan Lee
Changhan Lee
JCJiho Chang
Jiho Chang
SLSnagtae Lee
Snagtae Lee
DSDongmin Seo
Dongmin Seo
We studied electrochemical sensors using printed carbon nanotubes (CNT) film on a polyethylene telephtalate (PET) substrate. The mechanical stability of the printed CNT film (PCF) was confirmed by using bending and Scotch tape tests. In order to determine the optimum sensor structure, a resistance-type PCF sensor (R-type PCF sensor) and a comb-type PCF sensor (C-type PCF sensor) were fabricated and compared using a diluted NH3 droplet with various concentrations. The magnitude of response, response time, sensitivity, linearity, and limit of detection (LOD) were compared, and it was concluded that C-type PCF sensor has superior performance. In addition, the feasibility of PCF electrochemical sensor was investigated using 12 kinds of hazardous and noxious substances (HNS). The detection mechanism and selectivity of the PCF sensor are discussed.