Hugues Cadas

Dr. Hugues Cadas


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HBHugo Babel
Hugo Babel
POPatrick Omoumi
Patrick Omoumi
KCKillian Cosendey
Killian Cosendey
HCHugues Cadas
Hugues Cadas
BJBrigitte M. Jolles
Brigitte M. Jolles
JFJulien Favre
Julien Favre
While alterations in bone mineral density (BMD) are of interest in a number of musculoskeletal conditions affecting the knee, their analysis is limited by a lack of tools able to take full advantage of modern imaging modalities. This study introduced a new method, combining computed tomography (CT) and computational anatomy algorithms, to produce standardized three-dimensional BMD quantification in the distal femur and proximal tibia. The method was evaluated on ten cadaveric knees CT-scanned twice and processed following three different experimental settings to assess the influence of different scans and operators. The median reliability (intraclass correlation coefficient (ICC)) ranged from 0.96 to 0.99 and the median reproducibility (precision error (RMSSD)) ranged from 3.97 to 10.75 mg/cc for the different experimental settings. In conclusion, this paper presented a method to standardize three-dimensional knee BMD with excellent reliability and adequate reproducibility to be used in research and clinical applications. The perspectives offered by this novel method are further reinforced by the fact it relies on conventional CT scan of the knee. The standardization method introduced in this work is not limited to BMD and could be adapted to quantify other bone parameters in three dimension based on CT images or images acquired using different modalities.

Verified
Journal Article
Open access
PDF file
EBEmma Broillet-Olivier
Emma Broillet-Olivier
YWYaëlle Wenger
Yaëlle Wenger
NGNoah Gilliand
Noah Gilliand
HCHugues Cadas
Hugues Cadas
SSSara Sabatasso
Sara Sabatasso
JBJulien Brechbühl
Julien Brechbühl
Olfactory sensitivity to odorant molecules is a complex biological function influenced by both endogenous factors, such as genetic background and physiological state, and exogenous factors, such as environmental conditions. In animals, this vital ability is mediated by olfactory sensory neurons (OSNs), which are distributed across several specialized olfactory subsystems depending on the species. Using the phosphorylation of the ribosomal protein S6 (rpS6) in OSNs following sensory stimulation, we developed an ex vivo assay allowing the simultaneous conditioning and odorant stimulation of different mouse olfactory subsystems, including the main olfactory epithelium, the vomeronasal organ, and the Grueneberg ganglion. This approach enabled us to observe odorant-induced neuronal activity within the different olfactory subsystems and to demonstrate the impact of environmental conditioning, such as temperature variations, on olfactory sensitivity, specifically in the Grueneberg ganglion. We further applied our rpS6-based assay to the human olfactory system and demonstrated its feasibility. Our findings show that analyzing rpS6 signal intensity is a robust and highly reproducible indicator of neuronal activity across various olfactory systems, while avoiding stress and some experimental limitations associated with in vivo exposure. The potential extension of this assay to other conditioning paradigms and olfactory systems, as well as its application to other animal species, including human olfactory diagnostics, is also discussed.

25 March 2026 in Brain Sciences
Verified
Journal Article
Open access
PDF file
JSJesse Samir Shamsul
Jesse Samir Shamsul
APAlessandro Pesaresi
Alessandro Pesaresi
DSDaniele Starnoni
Daniele Starnoni
SMSamia Messaoudi
Samia Messaoudi
LDLorenzo Dolci
Lorenzo Dolci
LGLorenzo Giammattei
Lorenzo Giammattei
Objectives: This study aims to define the surgical anatomy, technical feasibility, advantages, and limitations of the TPPA through detailed cadaveric dissection and a representative clinical case, evaluating its potential as a safe and effective alternative to traditional approaches to the mesiotemporal lobe. Methods: A cadaveric dissection was performed on one adult head injected with colored latex, using standard microsurgical instruments and high-definition video documentation. Each procedural step was recorded and illustrated with cadaveric photographs. Additionally, a clinical case of mesiotemporal cavernous hemangioma resected via TPPA is presented, including an operative video. Results: The dissection demonstrated a direct and safe trajectory to the amygdala and hippocampal head, with clear identification of key vascular and white matter landmarks. In the clinical case, the lesion was completely resected with no postoperative neurological deficits. Conclusions: The TPPA represents a novel microsurgical corridor to the mesiotemporal region, minimizing cortical disruption, Sylvian fissure dissection, and manipulation of middle cerebral artery branches. Although its exposure is limited posteriorly, the TPPA could offer an optimal balance between functional preservation and surgical accessibility, constituting a valuable addition to the modern microsurgical armamentarium.

25 February 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KCKillian Cosendey
Killian Cosendey
JSJulien Stanovici
Julien Stanovici
HCHugues Cadas
Hugues Cadas
POPatrick Omoumi
Patrick Omoumi
BJBrigitte M. Jolles
Brigitte M. Jolles
JFJulien Favre
Julien Favre
Background: This study aimed to evaluate the accuracy of bone cuts and implant placements, simultaneously, for total knee arthroplasty (TKA) performed using a system with an active robotic arm. Methods: Two experienced orthopaedic surgeons performed TKA on ten cadaveric legs. Computed tomography scans were performed to compare the bone cuts and implant placements with the preoperative planning. The differences between the planned and actual bone cuts and implant placements were assessed using positional and angular errors in the three anatomical planes. Additionally, the cut–implant deviations were calculated. Statistical analysis was performed to detect systematic errors in the bone cuts and implant placements and to quantify the correlations between these errors. Results: The root-mean-square (RMS) errors of the bone cuts (with respect to the planning) were between 0.7–1.5 mm and 0.6–1.7°. The RMS implant placement errors (with respect to the planning) varied between 0.6–1.6 mm and 0.4–1.5°, except for the femur and tibia in the sagittal plane (2.9°). Systematic errors in the bone cuts and implant placements were observed, respectively, in three and two degrees of freedom. For cut–implant deviations, the RMS values ranged between 0.3–2.0 mm and 0.6–1.9°. The bone cut and implant placement errors were significantly correlated in eight degrees-of-freedom (ρ ≥ 0.67, p < 0.05). Conclusions: With most of the errors below 2 mm or 2°, this study supported the value of active robotic TKA in achieving accurate bone cuts and implant placements. The findings also highlighted the need for both accurate bone cuts and proper implantation technique to achieve accurate implant placements.

22 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HBHugo Babel
Hugo Babel
POPatrick Omoumi
Patrick Omoumi
KCKillian Cosendey
Killian Cosendey
JSJulien Stanovici
Julien Stanovici
HCHugues Cadas
Hugues Cadas
JFJulien Favre
Julien Favre
As knee osteoarthritis is a disease of the entire joint, our pathophysiological understanding could be improved by the characterization of the relationships among the knee components. Diverse quantitative parameters can be characterized using magnetic resonance imaging (MRI) and computed tomography (CT). However, a lack of methods for the coordinated measurement of multiple parameters hinders global analyses. This study aimed to design an expert-supervised registration method to facilitate multiparameter description using complementary image sets obtained by serial imaging. The method is based on three-dimensional tissue models positioned in the image sets of interest using manually placed attraction points. Two datasets, with 10 knees CT-scanned twice and 10 knees imaged by CT and MRI were used to assess the method when registering the distal femur and proximal tibia. The median interoperator registration errors, quantified using the mean absolute distance and Dice index, were ≤0.45 mm and ≥0.96 unit, respectively. These values differed by less than 0.1 mm and 0.005 units compared to the errors obtained with gold standard methods. In conclusion, an expert-supervised registration method was introduced. Its capacity to register the distal femur and proximal tibia supports further developments for multiparameter description of healthy and osteoarthritic knee joints, among other applications.

11 November 2026 in Operative Neurosurgery
Verified
Journal Article
Closed access
LDLorenzo Dolci
Lorenzo Dolci
AMAmine Mellal
Amine Mellal
JSJordan Squair
Jordan Squair
HCHugues Cadas
Hugues Cadas
SSSami SCHRANZ
Sami SCHRANZ
LGLorenzo Giammattei
Lorenzo Giammattei
BACKGROUND AND OBJECTIVES: The occipital artery–vertebral artery (OA–VA) bypass of the V3 segment has been described as a possible feasible revascularization strategy through the anterolateral approach. However, the impact of C1 transverse process removal on surgical corridor expansion, VA mobility, and microsurgical ergonomics has not been evaluated. In this cadaveric study, we assessed the anatomic and ergonomic effect of C1 transversectomy for OA–V3 bypass. METHODS: Five injected cadaveric specimens (10 sides) were subjected to paired analysis comparing standard anterolateral exposure (baseline) vs the same approach with C1 transversectomy and VA skeletonization. Quantitative end points included surgical working area, exposed VA length, working depth, and instrument divergence angle. Paired statistical analysis was calculated. RESULTS: C1 transversectomy resulted in a significant improvement in all major parameters of surgical exposure. The working area increased by 130% (from 226.1 to 519.1 mm 2 , P < .001), whereas the exposed VA length increased by 84% (from 12.7 to 23.4 mm, P = .002). VA mobility demonstrated the greatest relative gain, increasing by 207% (from 1.5 to 4.6 mm, P < .001). The instrument divergence angle also significantly improved, increasing by 109% (from 18.2° to 38.1°, P < .001). No statistically significant changes were observed in working depth. CONCLUSION: C1 transversectomy markedly enhances exposure, mobility, and operative ergonomics within the anterolateral OA–V3 corridor. These findings provide quantitative anatomic validation of a technical refinement that may improve reproducibility and safety of OA–VA bypass in selected clinical scenarios.