Sami SCHRANZ

Mr. Sami SCHRANZ

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2025 in International journal of legal medicine
Verified
Journal Article
Open access
PDF file
MLManel Lopez-Melia
Manel Lopez-Melia
VMVirginie Magnin
Virginie Magnin
SSSami SCHRANZ
Sami SCHRANZ
VAVincent Andrearczyk
Vincent Andrearczyk
ADAdrien Depeursinge
Adrien Depeursinge
SGSilke Grabherr
Silke Grabherr
Objectives: To assess the performance of automatic rib fracture detection of an existing deep learning (DL) model, nnDetection, on a postmortem (PM) CT scan dataset, and to identify the main factors of domain shift between clinical and PM CT imaging. Background: Rib fracture detection and classification in forensic investigations is a time-consuming yet crucial task that can contribute to determine the cause of death. DL models are a promising tool, as recent research shows that radiologists using DL models can detect rib fractures in clinical CT scans at higher sensitivity and in shorter time. Methods: A dataset of 50 PMCT scans (24% women; age: mean 61, range 19 – 96 years) was retrospectively collected and annotated, and used to train a first instance of the model, nnDetPM. Another instance of the model, nnDetClin, was trained on data from another dataset, RibFrac, consisting of 660 clinical CT scans (36% women; age: mean 55, range 21 – 94 years). Results: On the PM testing set, nnDetPM achieved an average sensitivity of 70.2% and an average precision (at 0.1 intersection over union) of 78.1%, whereas nnDetClin fell far behind at 19.8% average sensitivity and 25.5% average precision, indicating a substantial impact of the domain shift from clinical to PM CT data. Further inspection of the results showed that the main factors of this domain shift were the position of the arms and the presence of medical ware in the image acquisition area of the PMCT scans. Conclusion: The performance of nnDetPM, with an average sensitivity of 70.2%, was notable and comparable to that of radiologists. However, more advanced techniques must be explored to decide if DL models can overcome the domain shift factors.

29 January 2024 in Hand Surgery and Rehabilitation
Verified
Journal Article
Open access
SSSami SCHRANZ
Sami SCHRANZ
LCLorenzo Campana
Lorenzo Campana
MGMartine Giroud
Martine Giroud
SHStephane Hertig
Stephane Hertig
CECoraline Egger
Coraline Egger
Allodynia is a neuropathic pain triggered by a normally painless stimulus: for example, a slight touch on the skin or slight sensation of hot or cold is extremely painful. Rehabilitation is long and uncertain. Protecting the painful area from stimuli is a priority of care. This type of care is complex and challenging for the care team: the pain caused in manufacturing a classic molded orthosis is unbearable for the patient, and the orthosis has a limited lifetime, and experience shows that it is not possible to produce two identical splints. The present study consisted in creating protective splints by 3D printing, designed from data collected with the 3D surface scanner used in our forensic imaging and anthropology unit. The pros and cons of the 3D orthosis versus standard molded orthoses from the point of view of the patient and the practitioner are discussed, with evaluation of related indications of this technology.

25 March 2026 in Brain Sciences
Verified
Journal Article
Open access
PDF file
JSJesse Samir Shamsul
Jesse Samir Shamsul
APAlessandro Pesaresi
Alessandro Pesaresi
DSDaniele Starnoni
Daniele Starnoni
SMSamia Messaoudi
Samia Messaoudi
LDLorenzo Dolci
Lorenzo Dolci
LGLorenzo Giammattei
Lorenzo Giammattei
Objectives: This study aims to define the surgical anatomy, technical feasibility, advantages, and limitations of the TPPA through detailed cadaveric dissection and a representative clinical case, evaluating its potential as a safe and effective alternative to traditional approaches to the mesiotemporal lobe. Methods: A cadaveric dissection was performed on one adult head injected with colored latex, using standard microsurgical instruments and high-definition video documentation. Each procedural step was recorded and illustrated with cadaveric photographs. Additionally, a clinical case of mesiotemporal cavernous hemangioma resected via TPPA is presented, including an operative video. Results: The dissection demonstrated a direct and safe trajectory to the amygdala and hippocampal head, with clear identification of key vascular and white matter landmarks. In the clinical case, the lesion was completely resected with no postoperative neurological deficits. Conclusions: The TPPA represents a novel microsurgical corridor to the mesiotemporal region, minimizing cortical disruption, Sylvian fissure dissection, and manipulation of middle cerebral artery branches. Although its exposure is limited posteriorly, the TPPA could offer an optimal balance between functional preservation and surgical accessibility, constituting a valuable addition to the modern microsurgical armamentarium.

14 July 2026 in Surgical and Radiologic Anatomy
Verified
Journal Article
Open access
SSSami SCHRANZ
Sami SCHRANZ
HCHugues Cadas
Hugues Cadas
SSSara Sabatasso
Sara Sabatasso
Purpose: Intravascular injection of colored molding materials used either alone or in combination with radiological contrast agents is increasingly used to enhance vascular visualization in cadaveric specimens for anatomical education and surgical training. Published studies remain scattered and show substantial methodological variation. This structured literature review summarizes current practices regarding specimen preparation, injection techniques, casting materials, contrast agents, and imaging modalities, with particular emphasis on their educational applications. Materials and methods: A comprehensive literature search was conducted in PubMed, Scopus, Embase, Web of Science, and Google Scholar (1975–August 2025) using English, French, and German keywords. Reference lists were screened manually. After removal of duplicates, 702 records were screened, 145 full-text articles assessed, and 78 studies included. Results: Included studies demonstrated variability in casting materials (primarily latex, with silicone, epoxy, and acrylic resins also reported), contrast agents (iodinated and barium-based compounds and lead oxide for CT, with gadolinium-based formulations predominantly used for MRI), perfusion pressures, flushing strategies, and specimen conditions (fresh-frozen, formalin-fixed, and Thiel-embalmed). However, methodological heterogeneity and inconsistent reporting limited direct comparison between approaches. The review nevertheless identifies representative reported technical protocols and highlights the main practical variables influencing protocol selection. Conclusion: Contrast-enhanced vascular casting provides valuable tools for anatomy education and surgical training by enabling direct correlation between radiological datasets and anatomical dissection. Beyond summarizing the literature, this review also offers practical protocol-selection guidance according to educational, research, and imaging objectives. As such, it may serve as a useful reference for teams implementing or refining these techniques in modern teaching environments.

17 July 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
HPHéloïse Policet-Bétend
Héloïse Policet-Bétend
TJTomàs Jordà-Siquier
Tomàs Jordà-Siquier
GCGeraldine Cuenu
Geraldine Cuenu
MBMaeva Badré
Maeva Badré
SSSami SCHRANZ
Sami SCHRANZ
CLChristophe M Lamy
Christophe M Lamy
Human anatomy has traditionally been studied using low-resolution approaches such as cadaveric dissection and conventional medical imaging, limiting our understanding of macroscopic structures. Tissue clearing has emerged as a transformative approach, enabling three-dimensional mapping of organs at microscopic resolution, and offering the opportunity to interrogate anatomy across scales. However, its application to human organs remains challenging due to their size, density and optical properties. Here, we establish multiorgan CleLight (mCleLight) as a generalizable method for clearing, labeling and imaging whole human tissues. mCleLight is broadly applicable across major organ systems and enables the analysis of particularly challenging specimens, including highly heterogeneous samples, dense bones, pigmented tissues and decades-old formalin-fixed archival material. We demonstrate that controlled photoclearing is critical across human tissues both for efficient clearing and for quenching endogenous fluorescence, thereby substantially improving imaging depth as compared to previous methods. mCleLight allows specific labeling and quantitative analysis of complex extended structures such as collagen fibers, vasculature, and innervation, while preserving anatomical relationships, which cannot be easily done with classical histology. We integrated mCleLight into a pipeline with clinical imaging to achieve a comprehensive, multiscale understanding of organ architecture. We demonstrate the voxel-by-voxel alignment between MRI and microscopy datasets, merging cellular-scale detail and protein- specific labeling with macroscopic medical imaging. By bridging the gap between imaging scales and modalities, mCleLight provides a versatile method for integrated three- dimensional histological mapping and macroscopic anatomy of human organs in health and disease.

10 August 2026 in Forensic Imaging
Verified
Journal Article
Open access
FVF. Versili
F. Versili
SSSami SCHRANZ
Sami SCHRANZ
VMV. Magnin
V. Magnin
RGRaphael Giraud
Raphael Giraud
SGS. Grabherr
S. Grabherr
CEC. Egger
C. Egger