Developing a high-performing hydrogel with long-lasting skin adhesion, high ionic conductivity, mechanical stability, and fatigue resistance is a crucial issue in the field of wearable electronic devices. Because of their weak mechanical properties, zwitterion-based hydrogels are not suitable for application in wearable strain sensors despite their excellent adhesion to the skin. In this study, a hydrogel of polymer without additive was prepared by using polymerizable monomers consisting of zwitterionic 3-(1-vinyl-3-imidazolio)propanesulfonate (VIPS), anionic 2-acrylamido-2-methyl-1-propanesulfonic acid sodium salt (AMPSs), and acrylamide (AAm); the hydrogel is abbreviated as P(AMPSs/VIPS-co-AAm). The P(AMPSs/VIPS-co-AAm) hydrogel shows exceptional adhesive strength, reaching up to 26.29 kPa (lap shear to porcine skin) and high stretchability (with a fracture strain of 1282% and stress of 40 kPa). The high polarity of the AMPSs/VIPS pair improves the interfacial adhesion to the skin, the internal cohesion and recovery tendency. Unique structural characteristics of the hydrogel impart excellent fatigue resistance, network toughening, and electrical stability after multiple deformations. Thus, the prepared hydrogel has an ionic conductivity (0.51 S m−1), strain sensitivity, and long-term skin adhesion, and it demonstrates potential to be applied for wearable strain sensors.
To improve the heat resistance of acrylic-based pressure-sensitive adhesive (PSA), silicone-block-containing acrylic PSAs (SPSAs) were synthesized using a polydimethylsiloxane (PDMS)-based macro-azo-initiator (MAI). To evaluate the heat resistance of the PSA films, the probe tack and 90° peel strength were measured at different temperatures. The acrylic PSA showed that its tack curves changed from balanced debonding at 25 °C to cohesive debonding at 50 °C and exhibited a sharp decrease. However, in the case of SPSA containing 20 wt% MAI (MAI20), the balanced debonding was maintained at 75 °C, and its tack value hardly changed with temperature. As the MAI content increased, the peel strength at 25 °C decreased due to the microphase separation between PDMS- and acryl-blocks in SPSA, but the shear adhesion failure temperature (SAFT) increased almost linearly from 41.3 to 122.8 °C. Unlike stainless steel substrate, SPSA showed improved peel strength on a polypropylene substrate due to its low surface energy caused by PDMS block. Owing to the addition of 20 wt% silicone-urethane dimethacrylate oligomer and 200 mJ/cm2 UV irradiation dose, MAI20 showed significantly increased 90° peel strength at 25 °C (548.3 vs. 322.4 gf/25 mm for pristine MAI20). Its heat resistance under shear stress assessed by shear adhesion failure test (SAFT) exhibited raising in failure temperature to 177.3 °C when compared to non-irradiated sample.
Our study presents a PDA-based liposome sensor detecting Salmonella rapidly and accurately via colorimetric response. Functionalized with a Salmonella-binding aptamer, this sensor achieves detection within 15 minutes, visible to the naked eye.
2 November 2021 in Journal of Materials Chemistry C
The simultaneous integration of diverse performance attributes, such as self-adhesive capability, stretchability, mechanical stability, and high ionic conductivity, is one of the key issues in the research of wearable electronic devices. Moreover, a facile preparation method, as well as time efficiency and no heating requirement, is desirable for the use of hydrogels in widespread applications. In this study, a multi-functional hydrogel P(AMPSs-co-AAm)/SC was prepared by the rapid photo-polymerization of 2-acrylamido-2-methyl-1-propanesulfonic acid sodium salt (AMPSs) and acrylamide (AAm) in the presence of sodium caseinate (SC). P(AMPSs-co-AAm)/SC exhibited tight contact and reversible adhesion on various substrates, including glass, steel, plastic, and even human skin. According to the dynamic interaction system of P(AMPSs-co-AAm) and SC, the hydrogel exhibited outstanding stretchability (reaching a fracture strain of 2929% and a stress of 128 kPa), as well as excellent fatigue resistance and network toughening even after multiple stretching/recovery cycles. In addition, a polymeric ionic charge carrier, such as AMPSs, not only endowed a high ionic conductivity (up to 1.2 S m−1) to the hydrogel, but also structural stability, leading to the excellent electric stability of the hydrogel throughout repeated mechanical strain cycles. Our developed approach demonstrates the potential for application as long-life wearable strain sensors for detecting human body motion.
In this study, ionic conductive hydrogels were prepared with 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS). Acrylic acid (AA), acrylamide (AAm), and 2-hydroxyethyl acrylate (HEA) were used as comonomers to complement the adhesion properties and ion conductivity of AMPS hydrogels. Hydrogels were prepared by irradiating a 20 kGy dose of E-beam to the aqueous monomer solution. With the E-beam irradiation, the polymer chain growth and network formation simultaneously proceeded to form a three-dimensional network. The preferred reaction was determined by the type of comonomer, and the structure of the hydrogel was changed accordingly. When AA or AAm was used as a comonomer, polymer growth and crosslinking proceeded together, so a hydrogel with increased peel strength and tensile strength could be prepared. In particular, in the case of AA, it was possible to prepare a hydrogel with improved adhesion without sacrificing ionic conductivity. When the molar ratio of AA to AMPS was 3.18, the 90° peel strength of AMPS hydrogel increased from 171 to 428 gf/25 mm, and ionic conductivity slightly decreased, from 0.93 to 0.84 S/m. By copolymerisation with HEA, polymer growth was preferred compared with chain crosslinking, and a hydrogel with lower peel strength, swelling ratio, and ionic conductivity than the pristine AMPS hydrogel was obtained.
Epoxy structural adhesives have strong adhesion, minimal shrinkage and high thermal and chemical resistance. However, despite these excellent properties, their high-energy impact resistance should be improved to satisfy the increasing demands of the automotive industry. For this reason, we used four types of silica nanoparticles with different surface groups, such as polydimethylsiloxane (PDMS), hydroxyl, epoxy and amine groups, as toughening agents and examined their effect on the glass transition temperature (Tg), crosslinking density and phase separation of epoxy structural adhesives. High-energy impact resistance, mode I fracture toughness and lap shear strength were also measured to explain the effect of surface functional groups. Silica nanoparticles with reactive functional groups increased the mode I fracture toughness of epoxy structural adhesives without sacrificing the crosslinking density. Although the mode I fracture toughness of epoxy structural adhesives could not clearly show the effect of surface functional groups, the dynamic resistance to cleavage obtained by impact wedge-peel tests showed quite different values. At a 0.3 vol% content, epoxy-functionalized silica nanoparticles induced the highest value (40.2 N/mm) compared to PDMS (34.1 N/m), hydroxyl (34.9 N/mm), and amine (36.1 N/m). All of these values were significantly higher than those of pristine epoxy structural adhesive (27.7 N/mm).