Alireza Omidi

Dr. Alireza Omidi

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2023 in Cardio-Oncology
Verified
Journal Article
Open access
PDF file
AOAlireza Omidi
Alireza Omidi
EWElisabeth M. Weiss
Elisabeth M. Weiss
CTCory R. Trankle
Cory R. Trankle
MRMihaela Rosu-Bubulac
Mihaela Rosu-Bubulac
JWJohn S. Wilson
John S. Wilson
Purpose: To determine the role of magnetic resonance imaging (MRI)-based metrics to quantify myocardial toxicity following radiotherapy (RT) in human subjects through review of current literature. Methods: Twenty-one MRI studies published between 2011-2022 were identified from available databases. Patients received chest irradiation with/without other treatments for various malignancies including breast, lung, esophageal cancer, Hodgkin’s, and non-Hodgkin’s lymphoma. In 11 longitudinal studies, the sample size, mean heart dose, and follow-up times ranged from 10-81 patients, 2.0-13.9 Gy, and 0-24 months after RT (in addition to a pre-RT assessment), respectively. In 10 cross-sectional studies, the sample size, mean heart dose, and follow-up times ranged from 5-80 patients, 2.1-22.9 Gy, and 2-24 years from RT completion, respectively. Global metrics of left ventricle ejection fraction (LVEF) and mass/dimensions of cardiac chambers were recorded, along with global/regional values of T1/T2 signal, extracellular volume (ECV), late gadolinium enhancement (LGE), and circumferential/radial/longitudinal strain. Results: LVEF tended to decline at >20 years follow-up and in patients treated with older RT techniques. Changes in global strain were observed after shorter follow-up (13±2 months) for concurrent chemoradiotherapy. In concurrent treatments with longer follow-up (8.3 years), increases in left ventricle (LV) mass index were correlated with LV mean dose. In pediatric patients, increases in LV diastolic volume were correlated with heart/LV dose at 2 years post-RT. Regional changes were observed earlier post-RT. Dose-dependent responses were reported for several parameters, including: increased T1 signal in high-dose regions, a 0.136% increase of ECV per Gy, progressive increase of LGE with increasing dose at regions receiving >30 Gy, and correlation between increases in LV scarring volume and LV mean/V10/V25 Gy dose. Conclusion: Global metrics only detected changes over longer follow-up, in older RT techniques, in concurrent treatments, and in pediatric patients. In contrast, regional measurements detected myocardial damage at shorter follow-up and in RT treatments without concurrent treatment and had greater potential for dose-dependent response. The early detection of regional changes suggests the importance of regional quantification of RT-induced myocardial toxicity at early stages, before damage becomes irreversible. Further works with homogeneous cohorts are required to examine this matter.

23 December 2022 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
AOAlireza Omidi
Alireza Omidi
EWElisabeth Weiss
Elisabeth Weiss
JWJohn S. Wilson
John S. Wilson
MRMihaela Rosu‐Bubulac
Mihaela Rosu‐Bubulac
Purpose: Establish a workflow to evaluate radiotherapy (RT) dose variation induced by respiratory and cardiac motion on the left ventricle (LV) and left ventricular myocardium (LVM).Methods: Eight lung cancer patients underwent 4D‐CT, expiratory T1‐volumetric‐interpolated‐breath‐hold‐examination (VIBE), and cine MRI scans in expiration. Treatment plans were designed on the average intensity projection (AIP) datasets from 4D‐CTs. RT dose from AIP was transferred onto 4D‐CT respiratory phases. About 50% 4D‐CT dose was mapped onto T1‐VIBE (following registration) and from there onto average cine MRI datasets. Dose from average cine MRI was transferred onto all cardiac phases. Cumulative cardiac dose was estimated by transferring dose from each cardiac phase onto a reference cine phase following deformable image registration. The LV was contoured on each 4D‐CT breathing phase and was called clinical LV (cLV); this structure is blurred by cardiac motion. Additionally, LV, LVM, and an American Heart Association (AHA) model were contoured on all cardiac phases. Relative maximum/mean doses for contoured regions were calculated with respect to each patient's maximum/mean AIP dose.Results: During respiration, relative maximum and mean doses on the cLV ranged from −4.5% to 5.6% and −14.2% to 16.5%, respectively, with significant differences in relative mean doses between inspiration and expiration (P < 0.0145). During cardiac motion at expiration, relative maximum and mean doses on the LV ranged from 1.6% to 59.3%, 0.5% to 27.4%, respectively. Relative mean doses were significantly different between diastole and systole (P = 0.0157). No significant differences were noted between systolic, diastolic, or cumulative cardiac doses compared to the expiratory 4D‐CT (P > 0.14). Significant differences were observed in AHA segmental doses depending on tumour proximity compared to global LV doses on expiratory 4D‐CT (P < 0.0117).Conclusion: In this study, the LV dose was highest during expiration and diastole. Segmental evaluation suggested that future cardiotoxicity evaluations may benefit from regional assessments of dose that account for cardiopulmonary motion.

10 November 2023 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
AOAlireza Omidi
Alireza Omidi
EWElisabeth Weiss
Elisabeth Weiss
MRMihaela Rosu-Bubulac
Mihaela Rosu-Bubulac
GTGeorgia Thomas
Georgia Thomas
JWJohn S. Wilson
John S. Wilson

21 September 2022 in Research Square
Verified
Preprint
Open access
PDF file
AOAlireza Omidi
Alireza Omidi
EWElisabeth Weiss
Elisabeth Weiss
CTCory R. Trankle
Cory R. Trankle
MRMihaela Rosu-Bubulac
Mihaela Rosu-Bubulac
JWJohn S. Wilson
John S. Wilson
Purpose: To determine the role of magnetic resonance imaging (MRI)-based metrics to quantify myocardial toxicity following radiotherapy (RT) in human subjects through review of current literature. Methods: 21 MRI studies published between 2011-2022 were identified from available databases. Patients received chest irradiation with/without other treatments for various malignancies including breast, lung, esophageal cancer, Hodgkin’s, and non-Hodgkin’s lymphoma. In 11 longitudinal studies, the sample size, mean heart dose, and follow-up times ranged from 10-81 patients, 2.0-13.9 Gy, and 0-24 months after RT (in addition to a pre-RT assessment), respectively. In 10 cross-sectional studies, the sample size, mean heart dose, and follow-up times ranged from 5-80 patients, 2.1-22.9 Gy, and 2-24 years from RT completion, respectively. Global metrics of left ventricle ejection fraction (LVEF) and mass/dimensions of cardiac chambers were recorded, along with global/regional values of T1/T2 signal, extracellular volume (ECV), late gadolinium enhancement (LGE), and circumferential/radial/longitudinal strain. Results: LVEF tended to decline at >20 years follow-up and in patients treated with older RT techniques. Changes in global strain were observed after shorter follow-up (13±2 months) for concurrent chemoradiotherapy. In concurrent treatments with longer follow-up (8.3 years), increases in left ventricle (LV) mass index were correlated with LV mean dose. In pediatric patients, increases in LV diastolic volume were correlated with heart/LV dose at 2 years post-RT. Regional changes were observed earlier post-RT. Dose-dependent responses were reported for several parameters, including: increased T1 signal in high-dose regions, a 0.136% increase of ECV per Gy, progressive increase of LGE with increasing dose at regions receiving >30 Gy, and correlation between increases in LV scarring volume and LV mean/V10/V25 Gy dose. Conclusion: Global metrics only detected changes over longer follow-up, in older RT techniques, in concurrent treatments, and in pediatric patients. In contrast, regional measurements detected myocardial damage at shorter follow-up and in RT treatments without concurrent treatment and had greater potential for dose-dependent response. The early detection of regional changes suggests the importance of regional quantification of RT-induced myocardial toxicity at early stages, before damage becomes irreversible. Further works with homogeneous cohorts are required to examine this matter.

6 January 2025 in Radiation
Verified
Journal Article
Open access
PDF file
AOAlireza Omidi
Alireza Omidi
EWElisabeth M. Weiss
Elisabeth M. Weiss
MKMateb Al Khalifa
Mateb Al Khalifa
SKSiyong Kim
Siyong Kim
Background: We aimed to measure the pacemaker- and defibrillator-induced distortion at 0.35T and 3.0T magnetic fields. Methods: The pacemaker/defibrillator was placed at the top center of a water-filled/MagPhan phantom, followed by a T1 scan at 3T and a TrueFISP scan at 0.35T. The extent of distortion (i.e., the distance from the device to the furthest signal loss/void/rings) in the water-filled phantom was measured in MIM. For geometrical distortion (i.e., dislocation of geometrical structures), the spheres in the MagPhan phantom were contoured and their distortion was calculated based on their manufacturing coordinate positions. Results: The maximum extent of distortion caused by the defibrillator was 18.8 cm at 0.35T and 5.8 cm at 3.0T. Similarly, the maximum extent of distortion caused by the pacemaker was 9.28 cm at 0.35T and 2.8 cm at 3.0T. Geometrical distortion measurements using the MagPhan phantom showed that the maximum distortion caused by the defibrillator was 12.8 mm at 0.35T and 13.2 mm at 3.0T. Likewise, the maximum distortion caused by the pacemaker was 8.7 mm at 0.35T and 6.0 mm at 3.0T. Conclusions: Defibrillators cause larger distortions/signal voids than pacemakers, and require careful consideration when performing MRI-based treatment planning. To minimize distortion, sequences with lower sensitivity to magnetic field inhomogeneity should be used.