Mihaela Rosu-Bubulac

Dr. Mihaela Rosu-Bubulac

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2023 in Cardio-Oncology
Verified
Journal Article
Open access
PDF file
AOAlireza Omidi
Alireza Omidi
EWElisabeth M. Weiss
Elisabeth M. Weiss
CTCory R. Trankle
Cory R. Trankle
MRMihaela Rosu-Bubulac
Mihaela Rosu-Bubulac
JWJohn S. Wilson
John S. Wilson
Purpose: To determine the role of magnetic resonance imaging (MRI)-based metrics to quantify myocardial toxicity following radiotherapy (RT) in human subjects through review of current literature. Methods: Twenty-one MRI studies published between 2011-2022 were identified from available databases. Patients received chest irradiation with/without other treatments for various malignancies including breast, lung, esophageal cancer, Hodgkin’s, and non-Hodgkin’s lymphoma. In 11 longitudinal studies, the sample size, mean heart dose, and follow-up times ranged from 10-81 patients, 2.0-13.9 Gy, and 0-24 months after RT (in addition to a pre-RT assessment), respectively. In 10 cross-sectional studies, the sample size, mean heart dose, and follow-up times ranged from 5-80 patients, 2.1-22.9 Gy, and 2-24 years from RT completion, respectively. Global metrics of left ventricle ejection fraction (LVEF) and mass/dimensions of cardiac chambers were recorded, along with global/regional values of T1/T2 signal, extracellular volume (ECV), late gadolinium enhancement (LGE), and circumferential/radial/longitudinal strain. Results: LVEF tended to decline at >20 years follow-up and in patients treated with older RT techniques. Changes in global strain were observed after shorter follow-up (13±2 months) for concurrent chemoradiotherapy. In concurrent treatments with longer follow-up (8.3 years), increases in left ventricle (LV) mass index were correlated with LV mean dose. In pediatric patients, increases in LV diastolic volume were correlated with heart/LV dose at 2 years post-RT. Regional changes were observed earlier post-RT. Dose-dependent responses were reported for several parameters, including: increased T1 signal in high-dose regions, a 0.136% increase of ECV per Gy, progressive increase of LGE with increasing dose at regions receiving >30 Gy, and correlation between increases in LV scarring volume and LV mean/V10/V25 Gy dose. Conclusion: Global metrics only detected changes over longer follow-up, in older RT techniques, in concurrent treatments, and in pediatric patients. In contrast, regional measurements detected myocardial damage at shorter follow-up and in RT treatments without concurrent treatment and had greater potential for dose-dependent response. The early detection of regional changes suggests the importance of regional quantification of RT-induced myocardial toxicity at early stages, before damage becomes irreversible. Further works with homogeneous cohorts are required to examine this matter.

27 December 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
AOAlireza Omidi
Alireza Omidi
EWElisabeth Weiss
Elisabeth Weiss
JWJohn S. Wilson
John S. Wilson
MRMihaela Rosu-Bubulac
Mihaela Rosu-Bubulac
Purpose: Magnetic resonance imaging (MRI)‐based investigations into radiotherapy (RT)‐induced cardiotoxicity require reliable registrations of magnetic resonance (MR) imaging to planning computed tomography (CT) for correlation to regional dose. In this study, the accuracy of intra‐ and inter‐modality deformable image registration (DIR) of longitudinal four‐dimensional CT (4D‐CT) and MR images were evaluated for heart, left ventricle (LV), and thoracic aorta (TA).Methods and materials: Non‐cardiac‐gated 4D‐CT and T1 volumetric interpolated breath‐hold examination (T1‐VIBE) MRI datasets from five lung cancer patients were obtained at two breathing phases (inspiration/expiration) and two time points (before treatment and 5 weeks after initiating RT). Heart, LV, and TA were manually contoured. Each organ underwent three intramodal DIRs ((A) CT modality over time, (B) MR modality over time, and (C) MR contrast effect at the same time) and two intermodal DIRs ((D) CT/MR multimodality at same time and (E) CT/MR multimodality over time). Hausdorff distance (HD), mean distance to agreement (MDA), and Dice were evaluated and assessed for compliance with American Association of Physicists in Medicine (AAPM) Task Group (TG)‐132 recommendations.Results: Mean values of HD, MDA, and Dice under all registration scenarios for each region of interest ranged between 8.7 and 16.8 mm, 1.0 and 2.6 mm, and 0.85 and 0.95, respectively, and were within the TG‐132 recommended range (MDA < 3 mm, Dice > 0.8). Intramodal DIR showed slightly better results compared to intermodal DIR. Heart and TA demonstrated higher registration accuracy compared to LV for all scenarios except for HD and Dice values in Group A. Significant differences for each metric and tissue of interest were noted between Groups B and D and between Groups B and E. MDA and Dice significantly differed between LV and heart in all registrations except for MDA in Group E.Conclusions: DIR of the heart, LV, and TA between non‐cardiac‐gated longitudinal 4D‐CT and MRI across two modalities, breathing phases, and pre/post‐contrast is acceptably accurate per AAPM TG‐132 guidelines. This study paves the way for future evaluation of RT‐induced cardiotoxicity and its related factors using multimodality DIR.

23 October 2023 in Strahlentherapie und Onkologie
Verified
Journal Article
Closed access
PDF file
MRMihaela Rosu-Bubulac
Mihaela Rosu-Bubulac
CTCory R. Trankle
Cory R. Trankle
PMPranav Mankad
Pranav Mankad
JGJohn D. Grizzard
John D. Grizzard
KEKenneth A. Ellenbogen
Kenneth A. Ellenbogen
EWElisabeth Weiss
Elisabeth Weiss

28 September 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MRMihaela Rosu-Bubulac
Mihaela Rosu-Bubulac
HZHualiang Zhong
Hualiang Zhong
ICIndrin Julian Chetty
Indrin Julian Chetty
Background/Objectives: Thoracic re-irradiation is increasingly considered for recurrent, persistent, or new lung cancers after prior radiation therapy. The central clinical-technical challenge is relating prior and prospective doses across changes in anatomy, breathing state, fractionation, and imaging. Methods: This clinical-technical Perspective synthesizes consensus guidance, technical and the methodological literature, and representative clinical evidence to discuss rigid and deformable registration, dose mapping, biological normalization with EQD2/BED, uncertainty, quality assurance, and practical decision-making in lung re-irradiation. Results: Cumulative dose is an estimate with inherent uncertainty whose clinical value depends on the clinical question, anatomic stability, tissue correspondence, dose-transfer method, biological assumptions, and the consequence of error. Published cumulative dose constraints can provide useful orientation, but they are not universal pass/fail thresholds and should be interpreted together with their original endpoints, assumptions, and accumulation method. Conclusions: A focused, risk-adapted workflow can support more defensible use of cumulative dose in lung re-irradiation. Practical considerations in this article are intended to complement formal consensus guidance, institutional protocols, or patient-specific multidisciplinary judgment.