Masoud Nateghi

Mr. Masoud Nateghi

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MNMasoud Nateghi
Masoud Nateghi
MAMahdi Rahbar Alam
Mahdi Rahbar Alam
HAHossein Amiri
Hossein Amiri
SNSamaneh Nasiri
Samaneh Nasiri
RSReza Sameni
Reza Sameni
Understanding sleep stages is crucial for diagnosing sleep disorders, developing treatments, and studying sleep’s impact on overall health. With the growing availability of affordable brain monitoring devices, the volume of collected brain data has increased significantly. However, analyzing these data, particularly when using the gold standard multi-lead electroencephalogram (EEG), remains resource-intensive and time-consuming. To address this challenge, automated brain monitoring has emerged as a crucial solution for cost-effective and efficient EEG data analysis. A critical component of sleep analysis is detecting transitions between wakefulness and sleep states. These transitions offer valuable insights into sleep quality and quantity, essential for diagnosing sleep disorders, designing effective interventions, enhancing overall health and well-being, and studying sleep’s effects on cognitive function, mood, and physical performance. This study presents a novel EEG feature extraction pipeline for the accurate classification of various wake and sleep stages. We propose a noise-robust model-based Kalman filtering (KF) approach to track changes in a time-varying auto-regressive model (TVAR) applied to EEG data during different wake and sleep stages. Our approach involves extracting features, including instantaneous frequency and instantaneous power from EEG, and implementing a two-step classifier for sleep staging. The first step classifies data into wake, REM, and non-REM categories, while the second step further classifies non-REM data into N1, N2, and N3 stages. Evaluation on the extended Sleep-EDF dataset (Sleep-EDFx), with 153 EEG recordings from 78 subjects, demonstrated compelling results with classifiers including Logistic Regression, Support Vector Machines, Extreme Gradient Boosting (XGBoost), and Light Gradient Boosting Machine (LGBM). The best performance was achieved with the LGBM and XGBoost classifiers, yielding an overall accuracy of over 77%, a macro-averaged F1 score of 0.69, and a Cohen’s kappa of 0.68, highlighting the efficacy of the proposed method with a remarkably compact and interpretable feature set.

13 August 2025 in Physiological Measurement
Verified
Journal Article
Open access
SKSajjad Karimi
Sajjad Karimi
MNMasoud Nateghi
Masoud Nateghi
GCGabriela I Cestero
Gabriela I Cestero
LCLina Chitadze
Lina Chitadze
DEDeepanshi
Deepanshi
RSReza Sameni
Reza Sameni
Objective. Depression is a prevalent mental health disorder that significantly impacts well-being and quality of life. This study investigates the relationship between depression and cardiovascular function, exploring time-series features derived from electrocardiogram (ECG) and photoplethysmogram (PPG) data as potential biomarkers for depression prescreening. Approach. As part of a comprehensive psycholinguistic experiment, we collected data from 60 individuals, including both healthy participants and those with varying levels of depression, assessed using the Beck Depression Inventory-II (BDI-II) and the Patient Health Questionnaire-9 (PHQ-9). Bimodal features derived from both ECG and PPG data were used to develop machine learning models for depression risk classification, employing classifiers such as random forest, XGBoost, logistic regression, and support vector machines (SVMs). Additionally, regression models were built to predict depression severity based on ECG- and PPG-derived biomarkers. Main results. Key findings indicate that short-term variability (SD1) features in the ECG RR interval, peripheral systolic and diastolic phases from the PPG, and pulse duration significantly differ between healthy individuals and those at risk of depression. SVM achieved the best classification performance, with an area under the ROC curve of 0.83 ± 0.11 for BDI-II-based classification and 0.78 ± 0.11 for PHQ-9-based classification. SHapley Additive exPlanations analysis consistently identified systolic-SD1 and RR-SD1 as key predictors. Regression analysis further supported the role of cardiovascular features in assessing depression severity, yielding a mean absolute error of 10.18 for BDI-II and 5.27 for PHQ-9 score regression. Significance. This study demonstrates the feasibility of using wearable ECG and PPG technologies for depression prescreening. The findings suggest that cardiac activity-based biomarkers can contribute to the development of cost-effective, objective, and non-invasive tools for mental health assessment, complementing traditional diagnostic methods.


21 August 2025 in arXiv
Verified
Preprint
Open access
PDF file
MNMasoud Nateghi
Masoud Nateghi
RSReza Sameni
Reza Sameni
Oscillometry is the standard method for non-invasive, cuff-based blood pressure (BP) measurement, but it introduces systematic errors that may impact clinical accuracy. This study investigates the sources of these errors--primarily the limitations of oscillometry itself and respiration-induced fluctuations--using BP waveform data from the MIMIC database. Oscillometry tends to underestimate systolic BP and overestimate diastolic BP, while respiration introduces cyclical variations that further degrade measurement precision. To mitigate these effects, we propose an estimation-theoretic framework employing least squares (LS) and maximum likelihood (ML) methods for correcting both single and repeated BP measurements. LS estimation supports conventional multi-measurement averaging protocols, whereas the ML approach incorporates prior knowledge of measurement errors, offering improved performance. Our results demonstrate that leveraging statistical priors across multiple readings can enhance the accuracy of non-invasive BP monitoring, with potential implications for improving cardiovascular diagnosis and treatment.

13 November 2026 in Physiological Measurement
Verified
Journal Article
Open access
MNMasoud Nateghi
Masoud Nateghi
RSReza Sameni
Reza Sameni
Objective . Modern digital oscillometry and traditional auscultation-based blood pressure (BP) measurement share a similar cuff-based occlusive technique to sense BP: an external arm cuff is inflated above arterial pressure and then deflated while pressure changes due to arterial reopening and pulsation are detected and used to estimate BP. This process introduces inherent biases that can affect clinical assessments. This study models and characterizes these biases and develops an estimation-theoretic framework to mitigate them. Approach . Using the MIMIC database, we examine two major sources of BP measurement error: (1) systematic biases introduced by cuff-based occlusive measurement, and (2) respiratory-driven modulation of BP. Using a model of cuff–artery pressure interaction, we characterize errors in systolic BP (SBP) and diastolic BP (DBP) relative to a-line measurements, and analyze the association between respiration and short-term BP variability. We then evaluate least squares (LSs), maximum likelihood (ML), and Bayesian estimators for single and multiple BP measurements using leave-one-subject-out cross-validation. Main results . Simulated cuff-based measurements underestimated SBP by 9.7 ± 7.8 mmHg and overestimated DBP by 6.6 ± 4.8 mmHg on average. The proposed estimation frameworks substantially improved BP estimation errors in the simulated measurements. LS reduced estimation variability but retained the systematic bias, whereas ML corrected this bias, producing mean errors close to zero. Bayesian estimation further reduced mean absolute error (MAE) for most BP metrics. With three measurements, LS achieved MAEs of 9.7 ± 5.7 mmHg and 6.6 ± 3.6 mmHg for SBP and DBP, respectively, compared with 4.1 ± 4.0 mmHg and 2.8 ± 2.3 mmHg using ML. Bayesian estimation further reduced the MAEs to 3.6 ± 4.4 mmHg and 1.9 ± 2.1 mmHg, respectively. Significance . Cuff-based occlusive BP measurements are subject to inherent systematic biases. Modeling and correcting their systematic measurement errors can improve the accuracy and reliability of cuff-based noninvasive BP estimation, particularly when combined with repeated measurements and prior statistical information.