Bence Szabó

Dr. Bence Szabó

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2023 in Journal of Dentistry
Verified
Journal Article
Open access
VVViktória Vitai
Viktória Vitai
ANAnna Németh
Anna Németh
ESEleonóra Sólyom
Eleonóra Sólyom
LCLászló Márk Czumbel
László Márk Czumbel
BSBence Szabó
Bence Szabó
JBJudit Borbély
Judit Borbély
This network meta-analysis (NMA) aimed to compare the complete-arch scanning accuracy of different intraoral scanners (IOSs) to that of reference standard tessellation language (STL) files. Studies comparing the trueness and precision of IOS STL files with those of reference STL scans for different arch types (dentate, edentulous, completely edentulous with implants, and partially edentulous with implants) were included in this study. An electronic search of five databases restricted to the English Language was conducted in October 2021. A total of 3,815 studies were identified, of which 114 were eligible for inclusion. After study selection and data extraction, pair-wise comparison and NMA were performed to define the accuracy of scanning for four arch subgroups using four outcomes (trueness and precision expressed as mean absolute deviation and root mean square values). Cochrane guidelines and the QUADAS-2 tool were used to assess the risk of bias. GRADE was used for certainty assessment. Fifty-three articles were included in this NMA. Altogether, 26 IOSs were compared directly and indirectly in 10 network systems. The accuracy of IOSs scans were not significantly different from the reference scans for dentate arches (three IOSs), edentulous arches (three IOSs), and completely edentulous arches with implants (one IOS). The accuracy of the IOSs was significantly different from the reference scans for partially edentulous arches with implants. Significant accuracy differences were found between the IOSs, regardless of clinical scenarios. The accuracy of complete-arch scanning by IOSs differs based on clinical scenarios. Different IOSs should be used according to the complete arch type.

28 April 2023 in Journal of Dentistry
Verified
Journal Article
Open access
ANAnna Németh
Anna Németh
VVViktória Vitai
Viktória Vitai
LCLászló Márk Czumbel
László Márk Czumbel
BSBence Szabó
Bence Szabó
GVGábor Varga
Gábor Varga
JBJudit Borbély
Judit Borbély
Thus far, the findings of numerous studies conducted on the accuracy of three-dimensional (3D) printed dental models are conflicting. Therefore, the aim of the network meta-analysis (NMA) is to determine the accuracy of 3D printed dental models compared with digital reference models. Studies comparing the accuracy of 3D printed full-arch dental models manufactured using different printing techniques to initial STL files were included. This study was registered in PROSPERO (CRD42021285863). An electronic search was performed across four databases in November 2021, and search was restricted to the English language. A systematic search was conducted based on a prespecified search query. 16,303 articles were pooled after the removal of the duplicates. Following study selection and data extraction, 11 eligible studies were included in the NMA in 6 subgroups. The outcomes were specified as trueness and precision and expressed as root mean square (RMS) and absolute mean deviation values. Seven printing technologies were analyzed: stereolithography (SLA), digital light processing (DLP), fused deposition modeling/fused filament fabrication (FDM/FFF), MultiJet, PolyJet, continuous liquid interface production (CLIP), and LCD technology. The QUADAS-2 and GRADE were used to evaluate the risk of bias and certainty of evidence. SLA, DLP, and PolyJet technologies were the most accurate in producing full-arch dental models. The findings of the NMA suggest that SLA, DLP, and PolyJet technologies are sufficiently accurate for full-arch dental model production for prosthodontic purposes. In contrast, FDM/FFF, CLIP, and LCD technologies are less suitable for manufacturing dental models.

14 November 2024 in Heliyon
Verified
Journal Article
Open access
ZDZsuzsanna Domokos
Zsuzsanna Domokos
FSFanni Simon
Fanni Simon
EUEszter Uhrin
Eszter Uhrin
BSBence Szabó
Bence Szabó
SVSzilárd Váncsa
Szilárd Váncsa
ONOrsolya Nemeth
Orsolya Nemeth
Periodontitis is the irreversible destructive process of the periodontium and is the major cause of tooth loss in adults worldwide. Diagnosis of early-stage periodontal disease is crucial for improving outcomes, and to this end, the application of indicator biomarkers is gaining interest. One such method involves measuring the level of matrix metalloproteinase-8 (MMP-8). This systematic review and meta-analysis aims to evaluate the salivary MMP-8 level of periodontitis and gingivitis cases compared to healthy controls. We evaluated all studies that compared different laboratory techniques for measuring salivary MMP-8 levels in periodontitis and gingivitis patients, alongside healthy controls. The systematic search was performed on 10 October 2022 in three electronic databases. Pooled mean differences (MD) were calculated with 95 % confidence intervals (CIs) between the researched groups. In addition, the correlation coefficient results between MMP-8 values and other clinical parameters were narratively summarized. Based on 20 eligible studies (n = 1725), patients with periodontitis presented significantly higher MMP-8 levels (MD = 273.26 ng/ml, CI: 194.42; 352.10). Similarly, patients with gingivitis presented significantly higher salivary MMP-8 levels than healthy individuals (MD = 122.82 ng/ml, CI: 64.19; 181.45) based on the results of 10 eligible studies (n = 704). Additionally, we found higher MMP-8 levels in periodontitis compared to gingivitis (MD = 112.04 ng/ml, CI: 56.15; 167.92). The correlation results suggest that salivary MMP-8 is associated with different clinical periodontal parameters. Salivary MMP-8 level measurement may be a reliable method to distinguish between periodontal health and periodontal disease and also to distinguish between gingivitis and periodontitis. The measurement of salivary MMP-8 levels may have the potential to differentiate between periodontal health and disease reliably. Accordingly, it can be considered for integration into routine dental examinations as a quick and convenient method for the early detection and prevention of periodontitis, pending further validation.

19 October 2023 in Journal of Dentistry
Verified
Journal Article
Open access
ATAnna Takács
Anna Takács
EHEszter Hardi
Eszter Hardi
BCBianca Golzio Navarro Cavalcante
Bianca Golzio Navarro Cavalcante
BSBence Szabó
Bence Szabó
BKBarbara Kispelyi
Barbara Kispelyi
MKMárton Kivovics
Márton Kivovics
This meta-analysis aimed to determine the accuracy of currently available computer-assisted implant surgery (CAIS) modalities under in vitro conditions and investigate whether these novel techniques can achieve clinically acceptable accuracy. In vitro studies comparing the postoperative implant position with the preoperative plan were included. Risk of bias was assessed using the Quality Assessment Tool For In Vitro Studies (QUIN Tool) and a sensitivity analysis was conducted using funnel plots. A systematic search was performed on April 18, 2023, using the following three databases: MEDLINE (via PubMed), EMBASE, and Cochrane Central Register of Controlled Trials. No filters or restrictions were applied during the search. A total of 5,894 studies were included following study selection. Robotic- and static CAIS (sCAIS) had the most accurate and clinically acceptable outcomes. sCAIS was further divided according to the guidance level. Among the sCAIS groups, fully guided implant placement had the greatest accuracy. Augmented reality-based CAIS (AR-based CAIS) had clinically acceptable results for all the outcomes except for apical global deviation. Dynamic CAIS (dCAIS) demonstrated clinically safe results, except for horizontal apical deviation. Freehand implant placement was associated with the greatest number of errors. Fully guided sCAIS demonstrated the most predictable outcomes, whereas freehand sCAIS demonstrated the lowest accuracy. AR-based and robotic CAIS may be promising alternatives. To our knowledge, this is the first meta-analysis to evaluate the accuracy of robotic CAIS and investigate the accuracy of various CAIS modalities.

19 April 2023 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
ESEleonora Solyom
Eleonora Solyom
ESEszter Ágnes Szalai
Eszter Ágnes Szalai
LCLászló Márk Czumbel
László Márk Czumbel
BSBence Szabó
Bence Szabó
SVSzilárd Váncsa
Szilárd Váncsa
RFReka Fazekas
Reka Fazekas
Background: Ridge resorption following tooth extraction may be reduced by alveolar ridge preservation (ARP). Previous randomized clinical trials and systematic reviews have suggested that autogenous tooth bone graft (ATB) can be an effective alternative material for ARP. However, the results are heterogeneous. Therefore, our research aimed to evaluate the efficacy of ATB in ARP. Methods: A systematic search was conducted in Cochrane Library, Embase, MEDLINE and Scopus for studies published from inception to 31 November 2021. We searched searched for randomized, non-randomized controlled trials and case series reporting on ATB use for ARP. The primary outcome was the ridge width difference pre- and post-surgery, measured in millimetres (mm) measured on CBCT (cone beam computed tomography). The secondary outcomes were the histological results. We followed the PRISMA2020 recommendations for reporting our systematic review and meta-analysis. Results: The analysis included eight studies for the primary and six for the secondary outcomes. The meta-analysis revealed a positive ridge preservation effect with a pooled mean difference ridge width change of -0.72 mm. The pooled mean residual graft proportion was 11.61%, and the newly formed bone proportion was 40.23%. The pooled mean of newly formed bone proportion was higher in the group where ATB originated from both the root and crown of the tooth. Conclusions: ATB is an effective particulate graft material in ARP. Complete demineralization of the ATB tends to decrease the proportion of newly formed bone. ATB can be an attractive option for ARP. Trial registration: The study protocol was registered on PROSPERO (CRD42021287890).

17 June 2025 in Sleep Medicine Reviews
Verified
Journal Article
Open access
ABAnna Bardóczi
Anna Bardóczi
ZMZsombor Zoltán Matics
Zsombor Zoltán Matics
CTCaner Turan
Caner Turan
BSBence Szabó
Bence Szabó
ZMZsolt Molnar
Zsolt Molnar
GHGábor Horváth
Gábor Horváth
The primary etiologic risk factor for obstructive sleep apnea (OSA) is obesity. As incretin-based therapies, specifically glucagon-like peptide 1 (GLP-1) and dual GLP-1/glucose-dependent insulinotropic polypeptide (GIP) agonists, have shown promising outcomes in obesity management, these medications have generated interest in OSA therapy. To investigate their efficacy in OSA, we performed a systematic literature search following PRISMA and Cochrane Handbook guidelines for studies reporting apnea-hypopnea index (AHI) and incretin-based therapy in patients with OSA. Only randomized controlled trials were eligible for inclusion. Our literature search identified 813 publications, and 5 articles met the inclusion criteria. Collectively, the studies enrolled 1024 patients, lasted ≥12 weeks with liraglutide or tirzepatide, and resulted in significant reductions in body weight and/or body mass index. Incretin-based therapies were also associated with AHI reduction, with a mean change of -14.45 events/h (95 % CI: 25.90 to -2.99, p < 0.001). By pooling data of 5 RCTs in a pairwise meta-analysis, incretin-based therapies showed a greater effect on AHI than usual care, with a mean difference of -11.61 events/h (95 % CI: 22.91 to -0.31, p = 0.046). Our analysis demonstrates that weight reduction through incretin-based therapies improves AHI in OSA. Incretin-based therapies have the potential to treat sleep-disordered breathing in OSA patients with excess weight.