Background: COVID-19 is a serious and potentially deadly disease. Early diagnosis of infected individuals will play an important role in stopping its further escalation. The present gold standard for sampling is the nasopharyngeal swab method. However, several recent papers suggested that saliva-based testing is a promising alternative that could simplify and accelerate COVID-19 diagnosis. Objectives: Our aim was to conduct a meta-analysis on the reliability and consistency of SARS-CoV-2 viral RNA detection in saliva specimens. Methods: We have reported our meta-analysis according to the Cochrane Handbook. We searched the Cochrane Library, Embase, Pubmed, Scopus, Web of Science and clinical trial registries for eligible studies published between 1 January and 25 April 2020. The number of positive tests and the total number of tests conducted were collected as raw data. The proportion of positive tests in the pooled data were calculated by score confidence-interval estimation with the Freeman–Tukey transformation. Heterogeneity was assessed using the I2 measure and the χ2-test. Results: The systematic search revealed 96 records after removal of duplicates. Twenty-six records were included for qualitative analysis and 5 records for quantitative synthesis. We found 91% (CI 80–99%) sensitivity for saliva tests and 98% (CI 89–100%) sensitivity for nasopharyngeal swab (NPS) tests in previously confirmed COVID-19 patients, with moderate heterogeneity among the studies. Additionally, we identified 18 registered, ongoing clinical trials of saliva-based tests for detection of the virus. Conclusion: Saliva tests offer a promising alternative to NPS for COVID-19 diagnosis. However, further diagnostic accuracy studies are needed to improve their specificity and sensitivity.
This network meta-analysis (NMA) aimed to compare the complete-arch scanning accuracy of different intraoral scanners (IOSs) to that of reference standard tessellation language (STL) files. Studies comparing the trueness and precision of IOS STL files with those of reference STL scans for different arch types (dentate, edentulous, completely edentulous with implants, and partially edentulous with implants) were included in this study. An electronic search of five databases restricted to the English Language was conducted in October 2021. A total of 3,815 studies were identified, of which 114 were eligible for inclusion. After study selection and data extraction, pair-wise comparison and NMA were performed to define the accuracy of scanning for four arch subgroups using four outcomes (trueness and precision expressed as mean absolute deviation and root mean square values). Cochrane guidelines and the QUADAS-2 tool were used to assess the risk of bias. GRADE was used for certainty assessment. Fifty-three articles were included in this NMA. Altogether, 26 IOSs were compared directly and indirectly in 10 network systems. The accuracy of IOSs scans were not significantly different from the reference scans for dentate arches (three IOSs), edentulous arches (three IOSs), and completely edentulous arches with implants (one IOS). The accuracy of the IOSs was significantly different from the reference scans for partially edentulous arches with implants. Significant accuracy differences were found between the IOSs, regardless of clinical scenarios. The accuracy of complete-arch scanning by IOSs differs based on clinical scenarios. Different IOSs should be used according to the complete arch type.
Thus far, the findings of numerous studies conducted on the accuracy of three-dimensional (3D) printed dental models are conflicting. Therefore, the aim of the network meta-analysis (NMA) is to determine the accuracy of 3D printed dental models compared with digital reference models. Studies comparing the accuracy of 3D printed full-arch dental models manufactured using different printing techniques to initial STL files were included. This study was registered in PROSPERO (CRD42021285863). An electronic search was performed across four databases in November 2021, and search was restricted to the English language. A systematic search was conducted based on a prespecified search query. 16,303 articles were pooled after the removal of the duplicates. Following study selection and data extraction, 11 eligible studies were included in the NMA in 6 subgroups. The outcomes were specified as trueness and precision and expressed as root mean square (RMS) and absolute mean deviation values. Seven printing technologies were analyzed: stereolithography (SLA), digital light processing (DLP), fused deposition modeling/fused filament fabrication (FDM/FFF), MultiJet, PolyJet, continuous liquid interface production (CLIP), and LCD technology. The QUADAS-2 and GRADE were used to evaluate the risk of bias and certainty of evidence. SLA, DLP, and PolyJet technologies were the most accurate in producing full-arch dental models. The findings of the NMA suggest that SLA, DLP, and PolyJet technologies are sufficiently accurate for full-arch dental model production for prosthodontic purposes. In contrast, FDM/FFF, CLIP, and LCD technologies are less suitable for manufacturing dental models.
Background: Ridge resorption following tooth extraction may be reduced by alveolar ridge preservation (ARP). Previous randomized clinical trials and systematic reviews have suggested that autogenous tooth bone graft (ATB) can be an effective alternative material for ARP. However, the results are heterogeneous. Therefore, our research aimed to evaluate the efficacy of ATB in ARP. Methods: A systematic search was conducted in Cochrane Library, Embase, MEDLINE and Scopus for studies published from inception to 31 November 2021. We searched searched for randomized, non-randomized controlled trials and case series reporting on ATB use for ARP. The primary outcome was the ridge width difference pre- and post-surgery, measured in millimetres (mm) measured on CBCT (cone beam computed tomography). The secondary outcomes were the histological results. We followed the PRISMA2020 recommendations for reporting our systematic review and meta-analysis. Results: The analysis included eight studies for the primary and six for the secondary outcomes. The meta-analysis revealed a positive ridge preservation effect with a pooled mean difference ridge width change of -0.72 mm. The pooled mean residual graft proportion was 11.61%, and the newly formed bone proportion was 40.23%. The pooled mean of newly formed bone proportion was higher in the group where ATB originated from both the root and crown of the tooth. Conclusions: ATB is an effective particulate graft material in ARP. Complete demineralization of the ATB tends to decrease the proportion of newly formed bone. ATB can be an attractive option for ARP. Trial registration: The study protocol was registered on PROSPERO (CRD42021287890).
Background: Effective and selective oral rinses are required in the daily medical and dental practice. Currently mouthwashes used have substantial side effects. Objectives: Our aim was to evaluate the efficacy of chlorine dioxide-containing mouthwashes in comparison with other previously established mouth rinses in healthy adults using oral hygiene indices. Methods: This work was registered in PROSPERO (CRD42018099059) and carried out using multiple databases and reported according to the PRISMA statement. The search terms used were “chlorine dioxide” AND “oral”, and only randomised controlled trials (RCTs) were included. The primary outcome was the alteration of the plaque index (PI), while the secondary outcomes were the gingival index (GI) and bacterial counts. For the risk of bias assessment, the Cochrane Risk of Bias Tool was used. Statistical analysis for data heterogeneity was performed by Q-value and I2-tests. Results: 364 articles were found in the databases. After the selection process, only five RCTs were eligible for meta-analysis. Data heterogeneity was low. There were no statistical differences in effectiveness between chlorine dioxide and other effective mouth rinses in PI (0.720±0.119 vs 0.745±0.131; 95%; confidence intervals (CIs): 0.487-0.952 vs 0.489-1.001, respectively) and GI (0.712±0.130 vs 0.745±0.131; 95% CIs: 0.457–0.967 vs 0.489– 1.001, respectively) and also in bacterial counts. Conclusion: Chlorine dioxide reduces both plaque and gingival indices and bacterial counts in the oral cavity similar to other routinely used oral rinses, however, the evidence supporting this outcome is very limited. Therefore, further large scale RCTs are needed to decrease the risk of bias.
Background: Women are typically diagnosed with estrogen receptor-positive breast cancer around the postmenopausal period when declining estrogen levels initiate changes in lipid profiles. Aromatase inhibitors (AI) are used to prevent the progression of cancer; however, a further reduction in estrogen levels may have detrimental effects on lipid levels, which was our working hypothesis. Methods: Our meta-analysis was conducted on the lipid profiles of postmenopausal breast cancer patients at baseline and at different treatment time points. Results: We identified 15 studies, including 1708 patients. Studies using anastrozole (ANA), exemestane (EXE), letrozole (LET), and tamoxifen (TMX) were involved. Subgroup analyses revealed that 3- and 12-month administrations of LET and EXE lead to negative changes in lipid profiles that tend to alter the lipid profile undesirably, unlike ANA and TMX. Conclusions: Our results suggest that, despite statistically significant results, EXE and LET may not be sufficient to cause severe dyslipidemia in patients without cardiovascular comorbidities according to the AHA/ACC Guideline on the Management of Blood Cholesterol. However, the results may raise the question of monitoring the effects of AIs in patients, especially those with pre-existing cardiovascular risk factors such as dyslipidemia.