Jérémy CREUX

Mr. Jérémy CREUX

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JCJérémy CREUX
Jérémy CREUX
NONajla Haje Obeid
Najla Haje Obeid
TBThierry Boileau
Thierry Boileau
FMF. Meilbody-Tabar
F. Meilbody-Tabar
In electric powertrain traction applications, the adopted trend to improve the performance and efficiency of electromechanical power conversion systems is to increase supply voltages and inverter switching frequencies. As a result, electrical machine conductors are subjected to ever-increasing electrical stresses, leading to premature insulation degradation and eventual short-circuits. Winding condition monitoring is crucial to prevent such critical failures. Based on the scientific literature, several methods can be used for early identification of aging. A first solution is to monitor partial discharges. This method requires the use of a specific measurement device and an undisturbed test environment. A second solution is to monitor the inter-turn winding capacitance, which is directly related to the condition of the insulation and can cause a change in the stator impedance behavior. Several approaches can be used to estimate or characterize this impedance behavior. They must be performed on a machine at standstill, which limits their application. In this paper, a new characterization method is proposed to monitor the high-frequency stator impedance evolution of voltage source inverter-fed machines. This method can be applied at any time without removing the machine from its operating environment. The range and accuracy of the proposed frequency characterization depend in particular on the supply voltage level and the bandwidth of the measurement probes. The effects of parameters such as temperature, switching frequency, and DC voltage amplitude on the impedance characteristic were also studied and will be presented. Tests carried out on an automotive traction machine have shown that the first two series and parallel resonances of the high-frequency impedance can be accurately identified using the proposed technique. Therefore, by monitoring these resonances, it is possible to predict the aging rate of the conductor.

11 February 2025 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
JCJérémy CREUX
Jérémy CREUX
NONajla Haje Obeid
Najla Haje Obeid
TBThierry Boileau
Thierry Boileau
FMF. Meilbody-Tabar
F. Meilbody-Tabar
Permanent Magnet Assisted Synchronous Reluctance Motors (PMASynRM) are high energy density topologies, widely used in the automotive industry. However, their very good performances and efficiencies can be severely impaired by irreversible demagnetization faults of their rare- earth magnets. The aim of this work is to reliably detect local demagnetization faults in these machines. For this purpose, we used demagnetization frequency signatures of a baseline traction PMASynRM and based our diagnosis on high-order harmonic component behavior. Due to the low magnitude of these frequency features it may be difficult to identify the fault with a reliable and robust approach, therefore, a harmonic excitation scheme has been proposed to exacerbate local low severity demagnetization fault signatures. Finite Element (FE) modeling and analysis have been used to develop the method principles. Thus, based on previous findings, we prototype a faulty PMASynRM with a local demagnetization fault in the rotor which helped us experimentally validate our detection approach interests using search coils. Experimental results show that the proposed harmonic excitation strategy amplifies fault features while taking them out of the noise. Therefore, the proposed fault indicator is easier to assess, with a more sensible detection. Further works aim at exploring the method sensitivity to machine speed and operating point, while using machine voltages frequency content for the diagnosis.

9 April 2026
Verified
Thesis
Closed access
JCJérémy CREUX
Jérémy CREUX
Dans un contexte d'électrification rapide des groupes motopropulseurs dans le domaine des transports, les Machines Synchrones à Aimants Permanents (MSAP) ont subi un essor important lors de la dernière décennie. La popularité de ces machines vient de leur fiabilité, de leur forte densité de puissance et de couple, et de leur très bon rendement. Dans le secteur automobile, l'augmentation des tensions d'alimentation et des fréquences de découpage, couplée à la réduction des volumes disponibles, conduisent à l'exposition des MSAP à de fortes contraintes électriques, mécaniques et thermiques, ce qui favorise leur vieillissement. Parmi les défaillances les plus pernicieuses, on retrouve la démagnétisation des aimants permanents au rotor et l'usure des isolants entre conducteurs statoriques conduisant à des défauts de court-circuit inter-spires. Afin de garantir le rendement et la disponibilité de ces machines, le suivi de leur état de santé est indispensable pour mettre en place des stratégies de maintenance adaptées. Pour cela, des méthodes de détection sensibles et fiables sont nécessaires afin d'identifier des défaillances naissantes, dès les premiers symptômes de vieillissement. Dans cette optique, nous avons d'abord réalisé une étude bibliographique afin de comprendre les phénomènes de démagnétisation des aimants permanents dans les MSAP, ainsi que les approches de modélisation et de diagnostic utilisées. Puis, nous avons développé un modèle numérique de plusieurs MSAP afin de caractériser leur comportement en présence de démagnétisations locales. Les signatures caractéristiques de tels défauts ont alors été identifiées. L'impact topologique du type de bobinage, du nombre de paires de pôles, ou encore du design rotorique, sur les signatures de démagnétisations a également été investigué. Ensuite, ces travaux proposent d'utiliser l'injection d'harmoniques pour détecter les défauts de désaimantation de faibles sévérités. Une telle stratégie a été développée, puis, une étude expérimentale a permis de valider les conclusions obtenues lors de l'étude numérique, mais également d'évaluer la sensibilité des indicateurs de défaut proposés. Dans un second temps, la littérature a mis en avant l'évolution du comportement fréquentiel des bobinages statoriques avec la qualité des systèmes d'isolation. Ainsi, pour suivre leur état de santé et identifier de manière précoce une dégradation d'isolation dans le cadre d'applications embarquées, une approche de caractérisation non-invasive et sans retirer la machine de son environnement fonctionnel est nécessaire. Aucune approche issue de la littérature ne répond à ces critères. Pour lever ce verrou, nous avons alors utilisé l'excitation harmonique naturelle des bobinages lorsqu'ils sont alimentés par un onduleur de tension, piloté via modulation par largeur d'impulsions (MLI). La méthode proposée permet alors de reconstruire un diagramme de Bode du comportement impédant des bobinages et ainsi d'évaluer le module et la fréquence des deux premières résonances parallèle et série, caractéristiques de l'état de santé des isolants.