Najla Haje Obeid

Dr. Najla Haje Obeid


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2017 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
NONajla Haje Obeid
Najla Haje Obeid
ABAlexandre Battiston
Alexandre Battiston
TBThierry Boileau
Thierry Boileau
BNBabak Nahid-Mobarakeh
Babak Nahid-Mobarakeh
In order to improve hybrid and electrical vehicles functional safety and to avoid sudden failures, it is important to develop reliable and robust on-board diagnostics (OBD). This paper discusses the stator incipient fault diagnosis and monitoring of a permanent magnet synchronous motor for hybrid and electrical vehicles. Incipient stator fault appears as intermittent interturn faults. Studying this phenomenon had shown that it generates specific distortions in the statoric currents as well as in the reference voltages. The fault monitoring method is based on the identification of these specific distortions and on the localization of the phase containing the defected turns. The theoretical and the experimental results show the effectiveness of the method.

16 June 2016 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
NONajla Haje Obeid
Najla Haje Obeid
TBThierry Boileau
Thierry Boileau
BNBabak Nahid-Mobarakeh
Babak Nahid-Mobarakeh
This paper discusses incipient end-winding interturn faults in the stator winding of a permanent magnet synchronous motor caused by the mechanical vibrations of the concerned turns. With aging, the end-winding blocking system becomes weaker and turns insulation degrades until its breakdown. The fault is modeled by an intermittent interturn short circuit between the turns of the stator end winding. Intermittent fault occurrence disturbs the stator currents as well as the reference voltages leaving a specific fault signature. The detection method uses a pattern-adapted wavelet to detect fault occurrence. In this paper, it is applied to the quadrature reference voltage. Simulation and experimental results confirm the effectiveness of the proposed approach.

25 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JCJérémy CREUX
Jérémy CREUX
NONajla Haje Obeid
Najla Haje Obeid
TBThierry Boileau
Thierry Boileau
FMF. Meilbody-Tabar
F. Meilbody-Tabar
In electric powertrain traction applications, the adopted trend to improve the performance and efficiency of electromechanical power conversion systems is to increase supply voltages and inverter switching frequencies. As a result, electrical machine conductors are subjected to ever-increasing electrical stresses, leading to premature insulation degradation and eventual short-circuits. Winding condition monitoring is crucial to prevent such critical failures. Based on the scientific literature, several methods can be used for early identification of aging. A first solution is to monitor partial discharges. This method requires the use of a specific measurement device and an undisturbed test environment. A second solution is to monitor the inter-turn winding capacitance, which is directly related to the condition of the insulation and can cause a change in the stator impedance behavior. Several approaches can be used to estimate or characterize this impedance behavior. They must be performed on a machine at standstill, which limits their application. In this paper, a new characterization method is proposed to monitor the high-frequency stator impedance evolution of voltage source inverter-fed machines. This method can be applied at any time without removing the machine from its operating environment. The range and accuracy of the proposed frequency characterization depend in particular on the supply voltage level and the bandwidth of the measurement probes. The effects of parameters such as temperature, switching frequency, and DC voltage amplitude on the impedance characteristic were also studied and will be presented. Tests carried out on an automotive traction machine have shown that the first two series and parallel resonances of the high-frequency impedance can be accurately identified using the proposed technique. Therefore, by monitoring these resonances, it is possible to predict the aging rate of the conductor.

11 February 2025 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
JCJérémy CREUX
Jérémy CREUX
NONajla Haje Obeid
Najla Haje Obeid
TBThierry Boileau
Thierry Boileau
FMF. Meilbody-Tabar
F. Meilbody-Tabar
Permanent Magnet Assisted Synchronous Reluctance Motors (PMASynRM) are high energy density topologies, widely used in the automotive industry. However, their very good performances and efficiencies can be severely impaired by irreversible demagnetization faults of their rare- earth magnets. The aim of this work is to reliably detect local demagnetization faults in these machines. For this purpose, we used demagnetization frequency signatures of a baseline traction PMASynRM and based our diagnosis on high-order harmonic component behavior. Due to the low magnitude of these frequency features it may be difficult to identify the fault with a reliable and robust approach, therefore, a harmonic excitation scheme has been proposed to exacerbate local low severity demagnetization fault signatures. Finite Element (FE) modeling and analysis have been used to develop the method principles. Thus, based on previous findings, we prototype a faulty PMASynRM with a local demagnetization fault in the rotor which helped us experimentally validate our detection approach interests using search coils. Experimental results show that the proposed harmonic excitation strategy amplifies fault features while taking them out of the noise. Therefore, the proposed fault indicator is easier to assess, with a more sensible detection. Further works aim at exploring the method sensitivity to machine speed and operating point, while using machine voltages frequency content for the diagnosis.

1 January 2025 in Power Electronics and Drives
Verified
Journal Article
Open access
PDF file
Hadj Ahmed BELGHAZALIHadj Ahmed BELGHAZALI
Hadj Ahmed BELGHAZALI
NONajla Haje Obeid
Najla Haje Obeid
Eric MonmassonEric Monmasson
Eric Monmasson
NTNgoc-Tu Trinh
Ngoc-Tu Trinh
Lahoucine ID-KHAJINELahoucine ID-KHAJINE
Lahoucine ID-KHAJINE
This paper discusses encoderless control of a permanent magnet synchronous machine that is fed by an extra-low DC bus voltage and operates within the low-speed range. The focus is on optimising the parameters of the high-frequency (HF) voltage injections necessary for estimating the electrical position of the rotor. Although the encoderless control method adopted is pulsating carrier voltage injection, the optimisation algorithm can be applied to other methods as well. The quality of the estimated position is influenced by the amplitude of the injected voltages, which also affect the disturbance of the machine torque. Therefore, this study aims to strike a balance between the quality of the estimated position and injection-related intrusion. The paper proposes an experimental approach to determining the optimal injection level, enabling accurate estimation of the electrical position while reducing torque disturbance. It also presents the experimental validation results of the optimal injection voltage implementation.

2 April 2026
Verified
Thesis
Closed access
NONajla Haje Obeid
Najla Haje Obeid
Grâce à leurs avancées techniques en termes de poids, performances et fiabilité, les machines synchrones sont de plus en plus utilisées dans le domaine de transport et en particuliers dans l’aéronautique. Les stratégies de maintenances de ces systèmes électriques sont alors indispensables afin d'éviter des surcouts liés à des temps d'arrêt non planifiés. Ce document propose une analyse des conséquences d'un défaut inter-spires intermittent naissant dans l'enroulement statorique d'une Machine Synchrone à Aimants Permanents (MSAP). Ce type de défaut correspond à l'état peu avancé d'un futur court-circuit permanent. Jusqu'à présent, les études menées se sont limitées à la détection de courts-circuits inter-spires permanents. L'objectif de cette analyse est de définir une méthode de détection de ce type de défaut qui soit facile à mettre en œuvre. A partir d'une étude analytique du courant statorique d'une MSAP contrôlée en courant en présence de court-circuit intermittent, nous avons étudié l'impact des différentes grandeurs influençant la perturbation du courant. Nous avons constaté que la forme de la perturbation créée par le défaut était toujours la même et qu'elle était la signature du défaut intermittent dans le courant. Par la suite cette étude analytique a été validée expérimentalement. Dans la partie suivante nous avons étudié la sensibilité des méthodes de détection des courts-circuits inter-spires permanents appliquées au cas du court-circuit intermittent. Ces méthodes se sont révélées inadaptées pour la détection du défaut étudié dans ce travail. Nous avons donc proposé une méthode dédiée qui est basée sur la détection de la signature du défaut et qui utilise une transformation en ondelette adaptée. Il s'agit d'une méthode de détection de forme qui permet non seulement de détecter le défaut intermittent mais aussi de le distinguer des autres types de défauts. La performance de la méthode a été validée par les résultats de simulation et de manipulation. Dans une dernière partie, une étude plus générale sur le suivi de vieillissement des enroulements est proposée. Elle est basée sur le suivi de l'évolution des courbes d'admittance hautes fréquences d'un bobinage au cours du temps en utilisant les fonctions de transfert de ce dernier.