In this work the determination of mercury in fish samples by photochemical vapor generation (PVG) was investigated. Fish samples were dissolved in tetramethylammonium hydroxide, followed by the addition of n-propanol and water. Standards and samples were exposed to UV radiation in a photochemical reactor and mercury volatile compounds produced in the reactor were carried to a graphite furnace atomic absorption spectrometer (GF AAS) for measurements. The following parameters of the analysis were carefully investigated: sample preparation, the use of low-molecular weight organic compounds, the sample flow rate, carrier gas flow rate, mass of chemical modifiers, and GF AAS temperature program. The calibration curve showed a correlation coefficient higher than 0.99. A characteristic mass of 0.36 ng and a limit of detection of 0.03 μg g−1 were obtained, considering the amount of sample used in the determination (0.10 g). The sample throughput was 2.7 samples per hour (triplicate analysis). The relative standard deviations of the results obtained for three replicates of each sample ranged from 2 to 16%. The efficiency of PVG of Hg was 85% and it was estimated by comparison with conventional chemical vapor generation. The trueness of the method was confirmed by analyzing three certified reference materials. The proposed method was applied for the analysis of four real samples and the concentrations of mercury in these samples ranged from 0.31 to 3.17 μg g−1. The proposed method was simple and accurate, being an efficient alternative for the determination of mercury in fish.
The present work describes, for the first time, an eco-friendly capillary zone electrophoresis (CZE) methodology for determining apixaban (APX), an oral anticoagulant. Separation was carried out using a fused silica capillary with an applied voltage of 20 kV and hydrodynamic injection for 5 s at 50 mbar. The electrolyte system consisted of 50 mM sodium borate at pH 8.0. The method was validated as recommended by ICH, establishing selectivity, linearity, precision, accuracy, and robustness. The analytical procedure was linear in the range of 10–125 µg mL−1 (r = 0.999). The limits of detection and quantification were determined to be 1.77 µg mL−1 and 5.37 µg mL−1, respectively. Precision was evaluated by relative standard deviation (RSD), with an intra-day RSD (n = 6) of 0.96% and an inter-day RSD (n = 18) of 4.42%. The average recovery rates for the pharmaceutical samples were excellent, ranging from 98.03% to 101.01%, with an RSD of 1.51%. Moreover, the green profile of the method was evaluated using the National Environmental Methods Index (NEMI), Analytical Eco-Scale, Green Analytical Procedure Index (GAPI), and Analytical GREEnness Metric (AGREE) assessment tools. The results suggest that the CZE method aligns with the principles of green chemistry, offering a greener alternative for the routine analysis of APX quality control. Also, the method presents a low-cost analysis, using fewer organic solvents and minimizing waste generation compared to techniques commonly used in routine analysis.
15 July 2024 in International Journal of Gastronomy and Food Science