In this work the determination of mercury in fish samples by photochemical vapor generation (PVG) was investigated. Fish samples were dissolved in tetramethylammonium hydroxide, followed by the addition of n-propanol and water. Standards and samples were exposed to UV radiation in a photochemical reactor and mercury volatile compounds produced in the reactor were carried to a graphite furnace atomic absorption spectrometer (GF AAS) for measurements. The following parameters of the analysis were carefully investigated: sample preparation, the use of low-molecular weight organic compounds, the sample flow rate, carrier gas flow rate, mass of chemical modifiers, and GF AAS temperature program. The calibration curve showed a correlation coefficient higher than 0.99. A characteristic mass of 0.36 ng and a limit of detection of 0.03 μg g−1 were obtained, considering the amount of sample used in the determination (0.10 g). The sample throughput was 2.7 samples per hour (triplicate analysis). The relative standard deviations of the results obtained for three replicates of each sample ranged from 2 to 16%. The efficiency of PVG of Hg was 85% and it was estimated by comparison with conventional chemical vapor generation. The trueness of the method was confirmed by analyzing three certified reference materials. The proposed method was applied for the analysis of four real samples and the concentrations of mercury in these samples ranged from 0.31 to 3.17 μg g−1. The proposed method was simple and accurate, being an efficient alternative for the determination of mercury in fish.
The determination of cadmium and lead in fish samples has large analytical interest due to the potential toxicity of these elements. The development of fast and reliable analytical methods is extremely important for an effective control of contamination. In this work, the feasibility of Cd and Pb determination in fresh fish samples using direct sampling by electrothermal atomic absorption spectrometry (DS-ET AAS) was investigated. For optimization of the furnace temperature program, pyrolysis and atomization curves with TORT-2 and DORM-3 certified reference materials were carried out using chemical modifier (0.05% Pd + 0.03% Mg + 0.05% Triton X-100). The figures of merit obtained were: characteristic mass of 1.0 pg and 16 pg and limit of detection (LOD) of 0.2 μg kg−1 and 1.0 μg kg−1 for Cd and Pb, respectively, based on 8 mg of sample mass. The results obtained for certificated references materials were statistically not different from the certified values at 95% confidence level, using the calibration with aqueous standards, showing that this calibration method is suitable for this application. For assessment of the accuracy of the method, fresh fish samples were digested. The results obtained with direct determination of Cd and Pb in fresh fish samples and with microwave assisted acid digestion were statistically accordant. The developed method for analysis of fresh fish samples is accurate, simple, fast and suitable for routine application, avoiding digestion procedures or the drying/lyophilization and grinding procedures, usually used in DS analysis, reducing the preparation time, risk of contamination and costs.