YUKI HARA

Dr. YUKI HARA

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2017 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
KFKengo Fujii
Kengo Fujii
AIAtsuo Ito
Atsuo Ito
HMHirotaka Mutsuzaki
Hirotaka Mutsuzaki
SMShinji Murai
Shinji Murai
YSYu Sogo
Yu Sogo
Masashi YamazakiMasashi Yamazaki
Masashi Yamazaki
Loosening of screws is a common problem in orthopedic and maxillofacial surgery. Modifying the implant surface to improve the mechanical strength of screws has been tried and reported. We developed screws coated with fibroblast growth factor-2 (FGF-2)−apatite composite layers. We then showed, in a percutaneous external fixation model, that this composite layer had the ability to hold and release FGF-2 slowly, thereby reducing the risk of pin tract infection of the percutaneous external fixation. The objective of the current study was to clarify the effect of FGF-2−apatite composite layers on titanium screws on bone formation around the screw. We analyzed samples of previously performed animal experiments. The screws were coated with FGF-2−apatite composite layers by immersing them in supersaturated calcium phosphate solutions containing FGF-2. Then, the uncoated, apatite-coated, and FGF-2−apatite composite layer-coated screws were implanted percutaneously in rabbits. Finally, using inflammation-free histological sections, we histomorphometrically assessed them for the presence of bone formation. Weibull plot analysis was then applied to the data. On average, screws coated with FGF-2−apatite composite layers showed a significantly higher bone apposition rate than the uncoated or apatite-coated screws. Although the difference in the average bone apposition rate was small, the FGF-2−apatite composite layers produced a significant, marked reduction in the incidence of impaired bone formation around the screw compared with the incidence in the absence of FGF-2 (uncoated and apatite-coated screws). The probability of resulting in a bone apposition rate equal to or less than 63.75%, for example, is 3.5 × 10-4 for screws coated with the FGF-2−apatite composite layers versus 0.05 for screws in the absence of FGF-2. FGF-2-apatite composite layer coating significantly reduced the risk of impaired bone apposition to the screw. Thus, it is feasible to use titanium screws coated with FGF-2−apatite composite layers as internal fixation screws to decrease the risk of loosening.

18 January 2016 in Journal of Medical Case Reports
Verified
Journal Article
Open access
PDF file
SKSho Kohyama
Sho Kohyama
AKAKIHIRO KANAMORI
AKIHIRO KANAMORI
TTToshikazu Tanaka
Toshikazu Tanaka
YHYUKI HARA
YUKI HARA
Masashi YamazakiMasashi Yamazaki
Masashi Yamazaki
The carpal scaphoid is the most commonly fractured carpal bone in young adults after a fall on an outstretched arm that results in acute dorsal flexion of the wrist. However, stress fractures of the scaphoid are relatively rare. To the best of our knowledge, we describe the first case in the literature of carpal scaphoid stress fracture in a tennis player. An 18-year-old Japanese man who was an elite junior tennis player was referred to our hospital after radiography and computed tomography revealed a carpal scaphoid fracture. The patient presented with pain in the wrist joint and tenderness over the anatomical snuff-box with diffuse swelling and reduced active dorsal flexion and flexion of the right wrist. The patient was treated conservatively and resumed participation in competitive events 5 months after his initial presentation. In this case, the scaphoid stress fracture had resulted from repetitive practicing of the attacking backhand high volley, which involved excessive dorsal flexion of the wrist. Although rare, scaphoid stress fractures must be considered in tennis players with chronic wrist pain.

10 June 2011 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
YHYUKI HARA
YUKI HARA
YNYasumasa Nishiura
Yasumasa Nishiura
NONaoyuki Ochiai
Naoyuki Ochiai
SHSharula
Sharula
YNYoshiko Nakajima
Yoshiko Nakajima
HMHajime Mishima
Hajime Mishima
We have developed a new treatment for peripheral nerve defects: nerve‐lengthening method, and confirmed the efficacy and safety of our method using cynomolgus monkeys. A 20‐mm defect in the median nerve of monkey's forearms was repaired through the simultaneous lengthening of both nerve stumps with original nerve‐lengthening device. To evaluate nerve regeneration after neurorrhaphy, electrophysiological, histological, and functional recovery were examined and compared to the standard autografting. Nerve conduction velocity, axon maturation, and the result of functional test were superior in the nerve‐lengthening method than in the autografting. And there were no adverse events associated with our method. We concluded that this method is practical for clinical application. © 2011 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 30:153–161, 2012

1 May 2017 in Journal of Orthopaedic Science
Verified
Journal Article
Closed access
YHYUKI HARA
YUKI HARA
YNYasumasa Nishiura
Yasumasa Nishiura
NONaoyuki Ochiai
Naoyuki Ochiai
SMShinji Murai
Shinji Murai
MYMasashi Yamazaki
Masashi Yamazaki

27 March 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AIAkira Ikumi
Akira Ikumi
YYYuichi Yoshii
Yuichi Yoshii
TKTakamasa Kudo
Takamasa Kudo
SKSho Kohyama
Sho Kohyama
TOTakeshi Ogawa
Takeshi Ogawa
TITomoo Ishii
Tomoo Ishii
Background: The present study investigated the relationships between the median nerve cross-sectional area (CSA) and physical characteristics in patients with unilateral symptomatic carpal tunnel syndrome (CTS). Methods: Height, weight, body mass index (BMI), disease duration, results of electrodiagnostic testing (EDX), and median nerve CSA at the level of the wrist crease were recorded in 81 patients with CTS who presented with symptoms on only one side. Correlation coefficients between median nerve CSA and physical characteristics, disease duration, and results of EDX were analyzed. Results: Median nerve CSA at the wrist crease (mm2) was significantly larger on the symptomatic side (14.1 ± 3.8) than on the asymptomatic side (11.5 ± 2.9). Median nerve CSA correlated with body weight (correlation coefficient = 0.39) and BMI (correlation coefficient = 0.44) on the asymptomatic side, but not on the symptomatic side. These correlations were slightly stronger in females (correlation coefficient = 0.46) than in males (correlation coefficient = 0.40). No correlations between median nerve CSA and disease duration and the results of EDX were observed in both sides. Conclusions: In patients with unilateral symptomatic CTS, median nerve CSA correlated with BMI only on the asymptomatic side. The present results suggest that the relationship between median nerve CSA and BMI in CTS is significant until symptom onset but may be masked by edema and pseudoneuroma after its onset. A higher BMI is associated with a larger CSA of the median nerve, which may be a risk factor for the development of CTS.

26 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YSYukiyo Shimizu
Yukiyo Shimizu
TMTakahiko Mori
Takahiko Mori
KYKenichi Yoshikawa
Kenichi Yoshikawa
DKDaisuke Katane
Daisuke Katane
HTHiroyuki Torishima
Hiroyuki Torishima
HMHirotaka Mutsuzaki
Hirotaka Mutsuzaki
Myoelectric hands are beneficial tools in the daily activities of people with upper-limb deficiencies. Because traditional myoelectric hands rely on detecting muscle activity in residual limbs, they are not suitable for individuals with short stumps or paralyzed limbs. Therefore, we developed a novel electric prosthetic hand that functions without myoelectricity, utilizing wearable wireless sensor technology for control. As a preliminary evaluation, our prototype hand with wireless button sensors was compared with a conventional myoelectric hand (Ottobock). Ten healthy therapists were enrolled in this study. The hands were fixed to their forearms, myoelectric hand muscle activity sensors were attached to the wrist extensor and flexor muscles, and wireless button sensors for the prostheses were attached to each user’s trunk. Clinical evaluations were performed using the Simple Test for Evaluating Hand Function and the Action Research Arm Test. The fatigue degree was evaluated using the modified Borg scale before and after the tests. While no statistically significant differences were observed between the two hands across the tests, the change in the Borg scale was notably smaller for our prosthetic hand (p = 0.045). Compared with the Ottobock hand, the proposed hand prosthesis has potential for widespread applications in people with upper-limb deficiencies.