Carl Nelson

Dr. Carl Nelson

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2013 in Robotics and Autonomous Systems
Verified
Journal Article
Closed access
JBJosé Baca
José Baca
SHS.G.M. Hossain
S.G.M. Hossain
RDRaj Dasgupta
Raj Dasgupta
CNCarl Nelson
Carl Nelson
ADAyan Dutta
Ayan Dutta

1 January 2011 in Journal of Mechanical Design
Verified
Journal Article
Closed access
PDF file
XZXiaoli Zhang
Xiaoli Zhang
CNCarl Nelson
Carl Nelson
A new kinematic design methodology is presented for optimization of spherical serial mechanisms. First, a new index, combining global manipulability and the uniformity of manipulability over the workspace, is presented to improve the synthesis results. This method integrates multiple criteria (workspace size, the new manipulability index, and mechanism size) linearly in one objective function. All these criteria are optimized simultaneously to lead to a solution with better performance. By changing the priorities of each criterion, different sets of desirable kinematic performance can be expressed. An adaptation of the method using a multiobjective Pareto front is also illustrated. The optimization result for a spherical bevel-geared mechanism using a genetic algorithm demonstrated that the proposed method effectively improves the quality of the optimum solution and provides insight into the workings of the mechanism. In addition, this flexible and adaptable methodology also presents a general optimization approach for linkage synthesis.

15 October 2015 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
BZBaoliang Zhao
Baoliang Zhao
CNCarl Nelson
Carl Nelson
Robotic minimally invasive surgery (R-MIS) has achieved success in various procedures; however, the lack of haptic feedback is considered by some to be a limiting factor. The typical method to acquire tool–tissue reaction forces is attaching force sensors on surgical tools, but this complicates sterilization and makes the tool bulky. This paper explores the feasibility of using motor current to estimate tool-tissue forces and demonstrates acceptable results in terms of time delay and accuracy. This sensorless force estimation method sheds new light on the possibility of equipping existing robotic surgical systems with haptic interfaces that require no sensors and are compatible with existing sterilization methods.

4 May 2016 in Journal of Mechanisms and Robotics
Verified
Journal Article
Closed access
PDF file
BZBaoliang Zhao
Baoliang Zhao
CNCarl Nelson
Carl Nelson
Robot-assisted minimally invasive surgery (MIS) has gained popularity due to its high dexterity and reduced invasiveness to the patient; however, due to the loss of direct touch of the surgical site, surgeons may be prone to exert larger forces and cause tissue damage. To quantify tool–tissue interaction forces, researchers have tried to attach different kinds of sensors on the surgical tools. This sensor attachment generally makes the tools bulky and/or unduly expensive and may hinder the normal function of the tools; it is also unlikely that these sensors can survive harsh sterilization processes. This paper investigates an alternative method by estimating tool–tissue interaction forces using driving motors' current, and validates this sensorless force estimation method on a 3-degree-of-freedom (DOF) robotic surgical grasper prototype. The results show that the performance of this method is acceptable with regard to latency and accuracy. With this tool–tissue interaction force estimation method, it is possible to implement force feedback on existing robotic surgical systems without any sensors. This may allow a haptic surgical robot which is compatible with existing sterilization methods and surgical procedures, so that the surgeon can obtain tool–tissue interaction forces in real time, thereby increasing surgical efficiency and safety.

14 May 2008 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
XZXiaoli Zhang
Xiaoli Zhang
CNCarl Nelson
Carl Nelson
The size and limited dexterity of current surgical robotic systems are factors that limit their usefulness. To improve the level of assimilation of surgical robots in minimally invasive surgery (MIS), a compact, lightweight surgical robotic positioning mechanism with four degrees of freedom (DOFs) (three rotational DOFs and one translation DOF) is proposed in this paper. This spatial mechanism based on a bevel-gear wrist is remotely driven with three rotation axes intersecting at a remote rotation center (the MIS entry port). Forward and inverse kinematics are derived, and these are used for optimizing the mechanism structure given workspace requirements. By evaluating different spherical geared configurations with various link angles and pitch angles, an optimal design is achieved, which performs surgical tool positioning throughout the desired kinematic workspace while occupying a small space bounded by a hemisphere of radius 13.7cm. This optimized workspace conservatively accounts for collision avoidance between the patient and robot or internally between the robot links. This resultant mechanism is highly compact and yet has the dexterity to cover the extended workspace typically required in telesurgery. It can also be used for tool tracking and skills assessment. Due to the linear nature of the gearing relationships, it may also be well suited for implementing force feedback for telesurgery.

1 August 2020 in Mechanism and Machine Theory
Verified
Journal Article
Closed access
CNCarl Nelson
Carl Nelson
LNLaurence Nouaille
Laurence Nouaille
GPGérard Poisson
Gérard Poisson