Akira Shionoya

Dr. Akira Shionoya

Graduate School of Information and Management Systems Engineering, Nagaoka University of Technology, Niigata, Japan

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2020 in Proceedings
Verified
Conference Paper
Open access
PDF file
TWTakeshi Waga
Takeshi Waga
SUSoichiro Ura
Soichiro Ura
MNMasahito Nagamori
Masahito Nagamori
HUHisashi Uchiyama
Hisashi Uchiyama
Akira ShionoyaAkira Shionoya
Akira Shionoya
Wheelchair sports have a tendency to depend on the performance of wheelchairs, and the weight reduction of wheelchairs made of various alloys has helped improve the performance of players. Some players have mentioned, however, that the operability and riding comfort of competition wheelchair have been affected by changing the wheelchair materials; stiffness and weight are considered to be related to operability and riding comfort. In this experiment, we installed some weights on the center of the mass of a competitive wheelchair made of magnesium alloy to be the same mass of a wheelchair made of aluminum alloy; vibrations that occurred on both wheelchairs while driving were measured and compared. The experiment was performed using 3-axis sensors. This experiment showed that the vibration frequency of the wheelchair made of magnesium alloy was different from that made of aluminum alloy. This result was thought to be influenced by the difference in Young’s modulus or the specific weight.

18 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SAShimpei Aihara
Shimpei Aihara
RSRyusei SHIBATA
Ryusei SHIBATA
RMRyosuke Mizukami
Ryosuke Mizukami
TSTakara Sakai
Takara Sakai
Akira ShionoyaAkira Shionoya
Akira Shionoya
Wheelchair sports are recognized as an international sport, and research and support are being promoted to increase the competitiveness of wheelchair sports. For example, an electromyogram can observe muscle activity. However, it is generally used under controlled conditions due to the complexity of preparing the measurement equipment and the movement restrictions imposed by cables and measurement equipment. It is difficult to perform measurements in actual competition environments. Therefore, in this study, we developed a method to estimate myoelectric potential that can be used in competitive environments and does not limit physical movement. We developed a deep learning model that outputs surface myoelectric potentials by inputting camera images of wheelchair movements and the measured values of inertial sensors installed on wheelchairs. For seven subjects, we estimated the myoelectric potential during chair work, which is important in wheelchair sports. As a result of creating an in-subject model and comparing the estimated myoelectric potential with the myoelectric potential measured by an electromyogram, we confirmed a correlation (correlation coefficient 0.5 or greater at a significance level of 0.1%). Since this method can estimate the myoelectric potential without limiting the movement of the body, it is considered that it can be applied to the performance evaluation of wheelchair sports.

15 June 2020 in Proceedings
Verified
Conference Paper
Open access
PDF file
MNMasaki Nonaka
Masaki Nonaka
HKHoshi Kashiwazaki
Hoshi Kashiwazaki
SUSoichiro Ura
Soichiro Ura
MNMasahito Nagamori
Masahito Nagamori
HUHisashi Uchiyama
Hisashi Uchiyama
Akira ShionoyaAkira Shionoya
Akira Shionoya
Currently, various types of wheelchairs for badminton have been developed for weight saving and functional improvement. The purpose of this study was to evaluate each performance of two types of competitive wheelchairs for badminton made of two different metallic materials. One of the wheelchairs used in this study was made of magnesium composite material, which was 45 GPs of Young’s modulus, 1.738 g/cm3 of the specific weight, and 9.57 kg of weight. Another was made of scandium-aluminum composite material, which was 70 GPa of Young’s modulus, 2.70 g/cm3 of the specific weight, and 10.81 kg of weight. The frames and weights of the wheelchairs were similar. In this experiment, the subject’s electromyograms from six muscles in driving each wheelchair were measured and analyzed. Furthermore, the motion in driving was captured and analyzed using a three-dimensional motion capture system. This experiment led to the following result: no significant difference was found in wheelchair performance due to the different materials.

25 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SOSatoshi Ohashi
Satoshi Ohashi
Akira ShionoyaAkira Shionoya
Akira Shionoya
KHKeiu Harada
Keiu Harada
MNMasahito Nagamori
Masahito Nagamori
HUHisashi Uchiyama
Hisashi Uchiyama
This study examined competitive wheelchairs that facilitate sports participation. They can be moved straight ahead using only one arm. Our designed and developed competitive wheel-chairs have a dual hand-rim system. Their two hand-rims, attached to a drive wheel on one side, can be operated simultaneously for straight-ahead movement. Specifically, based on integrated electromyography (iEMG) data calculated from surface electromyography (sEMG), we examined the wheelchair loading characteristics, posture estimation, and effects on body posture during one-arm propulsion movement. The first experiment yielded insights into arm and shoulder-joint muscle activation from iEMG results obtained for two-hand propulsion and dual hand-rim system propulsion. Results suggest that muscle activation of one arm can produce equal propulsive force to that produced by two arms. The second experiment estimated the movement posture from iEMG during one-arm wheelchair propulsion. The external oblique abdominis is particularly important for one-arm wheelchair propulsion. The iEMG posture estimation validity was verified based on changes in the user body axis and seat pressure distribution. In conclusion, as confirmed by iEMG, which is useful to estimate posture during movement, one-arm wheelchair use requires different muscle activation sites and posture than when using two arms.

13 March 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
Akira ShionoyaAkira Shionoya
Akira Shionoya
YKYusuke Kenmotsu
Yusuke Kenmotsu
The purpose of this study was to develop the new wheel-chair which had the function to drive straight by one-hand operation. To perform this purpose, the driving force transmission axis (DFTA) which had transmitted the driving force from the one side of wheel to another side of that was developed. The wheel-chair could drive straight by one-hand operation by the DFTA. The large torque, however, was generated in the DFTA, because the DFTA transmitted the driving force from the one side of wheel to another side by the axis of small diameter. Furthermore, the shear stress in the DFTA generated by this torque would lead to the DFTA break. The shear stress in the DFTA was calculated to examine the axial strength and durability. On the DETA of the wheelchair, the maximum shear stress calculated from the torque in driving was 39.53 MP and this was defined as the standard of the demand specifications as a strength and durability of the DFTA.

31 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
TATakenori Aida
Takenori Aida
Akira ShionoyaAkira Shionoya
Akira Shionoya
HNHirofumi Nonaka
Hirofumi Nonaka
KHKouji Hayami
Kouji Hayami
HUHisashi Uchiyama
Hisashi Uchiyama
SKShinji Kimura
Shinji Kimura
(1) Background: When measuring anaerobic work threshold (AT), the conventional V-slope method includes the subjectivity of the examiner, which cannot be eliminated completely. Therefore, we implemented an engineering method using strucchange to objectively search for the inflection point of AT. (2) Methods: Seventeen subjects (15 men and 2 women) were included in the study. The subjects rode an ergometer and performed a ramp load test for 18 min and 30 s. (3) Results: In VE (Ventilation), 11 out of 12 subjects had the same results with 95% confidence intervals for the AT by the strucchange and respiratory metabolic apparatus. In VCO2 (Carbon dioxide emissions), 9 out of 12 subjects had the same results with 95% confidence intervals for the AT with the strucchange and respiratory metabolic apparatus. In VE, 3 out of 12 subjects showed the same results for respiratory metabolic analysis and the AT by the V-slope method. In VCO2, 3 out of 12 subjects showed the same results for the respiratory metabolic analysis and AT by the V-slope method in VCO2. (4) Conclusions: Strucchange was more objective and significant in identifying the AT than the V-slope method.