Ashenafi Belihu Tadesse

Mr. Ashenafi Belihu Tadesse

Graduate Institute of Automation and Control, National Taiwan University of Science and Technology, Taipei, Taiwan
+1
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2022 in Energy Reports
Verified
Journal Article
Open access
Ashenafi Belihu TadesseAshenafi Belihu Tadesse
Ashenafi Belihu Tadesse
EAEskinder Anteneh Ayele
Eskinder Anteneh Ayele
AOAlemayehu Orshiso Olonje
Alemayehu Orshiso Olonje

29 November 2024 in Toxics
Verified
Journal Article
Open access
PDF file
CKCheng-Hao Ko
Cheng-Hao Ko
WKWei-Yi Kong
Wei-Yi Kong
Abel Chernet KabisoAbel Chernet Kabiso
Abel Chernet Kabiso
韋邱韋懷 邱
韋懷 邱
Ashenafi Belihu TadesseAshenafi Belihu Tadesse
Ashenafi Belihu Tadesse
HLHung Hsun Hung Lin
Hung Hsun Hung Lin
Growing concerns about the health risks of melamine adulteration in food products highlight the urgent need for reliable detection methods. However, the long-term effects of chronic low-level melamine exposure remain inadequately explored. This study introduces THE ONE InstantCare platform, a portable immunoassay analyzer integrating a SpectroChip-based spectral processing unit (SPU) with lateral flow immunoassay (LFIA) for sensitive and accurate quantification of melamine in human urine. This platform provides a cost-effective, rapid, and user-friendly point-of-care (POC) solution for melamine detection. Analytical evaluations across eight melamine concentrations (0–100 parts per billion, ppb) achieved a limit of detection (LOD) of 1.91 ppb. Validation with 24 human urine samples demonstrated strong concordance with liquid chromatography–mass spectrometry (LC-MS), yielding an intraclass correlation coefficient (ICC) of 0.9220, a Pearson correlation coefficient of 0.9389, and 95% agreement in Bland–Altman analysis. High reproducibility was observed, with an intraday coefficient of variation (CV) of 6.53% and acceptable interday CV values, while interference studies confirmed reliability in the presence of common biological substances. By delivering results in approximately 10 min, THE ONE InstantCare platform significantly reduces analysis time compared to LC-MS, which typically requires several hours. This novel platform enhances food safety surveillance and advances human health risk assessments, particularly for evaluating melamine-linked kidney damage. Its versatility and robust performance make it a promising tool for environmental monitoring and clinical diagnostics, enabling the detection of diverse biomarkers with high sensitivity and reproducibility.

12 September 2024 in Heliyon
Verified
Journal Article
Open access
CKCheng-Hao Ko
Cheng-Hao Ko
Ashenafi Belihu TadesseAshenafi Belihu Tadesse
Ashenafi Belihu Tadesse
Abel Chernet KabisoAbel Chernet Kabiso
Abel Chernet Kabiso
Most urine test strips are intended to enable the general population to rapidly and easily diagnose potential renal disorders. It is semi-quantitative in nature, and although the procedure is straightforward, certain factors will affect the judgmental outcomes. This study describes rapid and accurate quantification of twelve urine test strip parameters: leukocytes, nitrite, urobilinogen, protein, pH, occult blood, specific gravity, ketone, bilirubin, glucose, microalbumin, and creatinine using a micro-electromechanical system (MEMS)-based spectrophotometer, known as a spectrochip. For each parameter, absorption spectra were measured three times independently at eight different concentration levels of diluted standard solutions, and the average spectral intensities were calculated to establish the calibration curve under the characteristic wavelength (λc). Then, regression analysis on the calibration curve was performed with GraphPad Prism software, which revealed that the coefficient of determination (R2) of the modeled calibration curves was greater than 0.95. This result illustrates that the measurements exceed standard levels, confirming the importance of a spectrochip for routine multi-parameter urine analysis. Thus, it is possible to obtain the spectral signal strength for each parameter at its characteristic wavelength in order to compare directly with the calibration curves in the future, even in situations when sample concentration is unknown. Additionally, the use of large testing machines can be reduced in terms of cost, time, and space by adopting a micro urine testing platform based on spectrochip, which also improves operational convenience and effectively enables point-of-care (POC) testing in urinalysis.

23 June 2025 in RSC Advances
Verified
Journal Article
Open access
KGKidane Goitom Gerezgiher
Kidane Goitom Gerezgiher
DTDessie Tafere
Dessie Tafere
TTTesfay Gebremikael Teklehaimanot
Tesfay Gebremikael Teklehaimanot
Ashenafi Belihu TadesseAshenafi Belihu Tadesse
Ashenafi Belihu Tadesse
ADAyalew Manahilie Dinkirie
Ayalew Manahilie Dinkirie
HZHagos Woldeghebriel Zeweldi
Hagos Woldeghebriel Zeweldi
In this work, the electronic and structural properties of Cu m −1 In m Te 2 m −2 neutral and anion clusters are studied.


27 October 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Ashenafi Belihu TadesseAshenafi Belihu Tadesse
Ashenafi Belihu Tadesse
CKCheng-Hao Ko
Cheng-Hao Ko
Calibration transfer for portable reagent-strip spectroscopy is challenged by optical and instrumental variation. SpecCal-Transfer examines physics-guided spectral augmentation using 288 SpectroChip spectra representing 12 reagent-strip response classes, eight nominal control-mixture fractions, and three repeated acquisitions. Simulated gain, baseline drift, wavelength displacement, noise, spectral smoothing, missing-band corruption, and combined changes were used to evaluate source-only regression, shift-aware augmentation, neural correlation alignment (CORAL), maximum mean discrepancy (MMD), conventional standardization, and simulated limited-reference adaptation. In an extremely randomized trees (ExtraTrees) evaluation, physics-guided training reduced moderate wavelength-shift root-mean-square error (RMSE) from 0.1476 to 0.1233 (16.53% mean paired reduction) and combined-shift RMSE from 0.1504 to 0.1232 (18.17%). An independent training-size control yielded 0.1240 with expanded augmentation versus 0.1502 without augmentation under moderate wavelength shifts; size-matched gains were smaller. Under wavelength perturbations at previously withheld interior fractions, physics-guided augmentation achieved RMSE 0.1612 versus 0.1661 for a magnitude-matched generic control. Neural alignment and simulated recalibration had condition-dependent effects. These results establish computational robustness under specified measurement mechanisms, not experimental inter-device transfer or analyte-specific concentration accuracy.