Abel Chernet Kabiso

Mr. Abel Chernet Kabiso

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2024 in Toxics
Verified
Journal Article
Open access
PDF file
CKCheng-Hao Ko
Cheng-Hao Ko
WKWei-Yi Kong
Wei-Yi Kong
Abel Chernet KabisoAbel Chernet Kabiso
Abel Chernet Kabiso
韋邱韋懷 邱
韋懷 邱
Ashenafi Belihu TadesseAshenafi Belihu Tadesse
Ashenafi Belihu Tadesse
HLHung Hsun Hung Lin
Hung Hsun Hung Lin
Growing concerns about the health risks of melamine adulteration in food products highlight the urgent need for reliable detection methods. However, the long-term effects of chronic low-level melamine exposure remain inadequately explored. This study introduces THE ONE InstantCare platform, a portable immunoassay analyzer integrating a SpectroChip-based spectral processing unit (SPU) with lateral flow immunoassay (LFIA) for sensitive and accurate quantification of melamine in human urine. This platform provides a cost-effective, rapid, and user-friendly point-of-care (POC) solution for melamine detection. Analytical evaluations across eight melamine concentrations (0–100 parts per billion, ppb) achieved a limit of detection (LOD) of 1.91 ppb. Validation with 24 human urine samples demonstrated strong concordance with liquid chromatography–mass spectrometry (LC-MS), yielding an intraclass correlation coefficient (ICC) of 0.9220, a Pearson correlation coefficient of 0.9389, and 95% agreement in Bland–Altman analysis. High reproducibility was observed, with an intraday coefficient of variation (CV) of 6.53% and acceptable interday CV values, while interference studies confirmed reliability in the presence of common biological substances. By delivering results in approximately 10 min, THE ONE InstantCare platform significantly reduces analysis time compared to LC-MS, which typically requires several hours. This novel platform enhances food safety surveillance and advances human health risk assessments, particularly for evaluating melamine-linked kidney damage. Its versatility and robust performance make it a promising tool for environmental monitoring and clinical diagnostics, enabling the detection of diverse biomarkers with high sensitivity and reproducibility.

12 September 2024 in Heliyon
Verified
Journal Article
Open access
CKCheng-Hao Ko
Cheng-Hao Ko
Ashenafi Belihu TadesseAshenafi Belihu Tadesse
Ashenafi Belihu Tadesse
Abel Chernet KabisoAbel Chernet Kabiso
Abel Chernet Kabiso
Most urine test strips are intended to enable the general population to rapidly and easily diagnose potential renal disorders. It is semi-quantitative in nature, and although the procedure is straightforward, certain factors will affect the judgmental outcomes. This study describes rapid and accurate quantification of twelve urine test strip parameters: leukocytes, nitrite, urobilinogen, protein, pH, occult blood, specific gravity, ketone, bilirubin, glucose, microalbumin, and creatinine using a micro-electromechanical system (MEMS)-based spectrophotometer, known as a spectrochip. For each parameter, absorption spectra were measured three times independently at eight different concentration levels of diluted standard solutions, and the average spectral intensities were calculated to establish the calibration curve under the characteristic wavelength (λc). Then, regression analysis on the calibration curve was performed with GraphPad Prism software, which revealed that the coefficient of determination (R2) of the modeled calibration curves was greater than 0.95. This result illustrates that the measurements exceed standard levels, confirming the importance of a spectrochip for routine multi-parameter urine analysis. Thus, it is possible to obtain the spectral signal strength for each parameter at its characteristic wavelength in order to compare directly with the calibration curves in the future, even in situations when sample concentration is unknown. Additionally, the use of large testing machines can be reduced in terms of cost, time, and space by adopting a micro urine testing platform based on spectrochip, which also improves operational convenience and effectively enables point-of-care (POC) testing in urinalysis.

1 December 2018 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
FFFareeza F
Fareeza F
CRChunchu Rambabu
Chunchu Rambabu
SKS. Krishnaveni
S. Krishnaveni
Abel Chernet KabisoAbel Chernet Kabiso
Abel Chernet Kabiso
This Paper is to enable the Siemens (Programmable Logic Control) CPU 313-5A to communicate with the Lab VIEW and to control the process accuracy by image processing. The communication between CPU 313-5A and Lab VIEW is via OPC (OLE for Process Control).Process Accuracy is achieved with the use of Labview Image Processing and Gray Scale matching Pattern. Accuracy in the gray scale matching will purely depend on the calibration of the camera with respect to the corresponding image. The digital output from the labview is communicated to PLC via Ethernet Protocol for the industrial process control. With the use of Labview the dead time while using the normal image vision module in PLC can be minimized. Labview uses the gray scale matching technique which is more accurate than the normal image vision module used in PLC.

16 August 2021 in International Journal of Nonlinear Dynamics and Control
Verified
Journal Article
Closed access
Abel Chernet KabisoAbel Chernet Kabiso
Abel Chernet Kabiso
GTGebremicheal Teame
Gebremicheal Teame
When vehicle speed increases, stable and powerful brake system is required to ensure the safety of the vehicle and passengers. For high speed braking of vehicle, contactless eddy current brake (ECB) is developed and applied to antilock brake system (ABS). An adaptive sliding mode controller for ABS using eddy current is presented with a sliding mode observer (SMO). Using vehicle acceleration, wheel speeds, and braking torque, the vehicle velocity estimated by SMO. To control the system based on wheel slip, half-car model is developed by considering uncertainty of the road slope and aerodynamic drag force. According to the controller, the vehicle ABS model is built with MATLAB Simulink. The response of controller is compared in terms of braking time and stopping distance. The results indicate proposed controller algorithm achieves minimum braking time and minimum stopping distance on selected roads.