Objectives: The benefit of using the electroacoustic functionality was tested compared to electric stimulation alone. Two different cut-off frequencies between acoustic and electric stimulation were tried. Methods: Performance and subjective preference in 10 subjects was measured with electric only and electroacoustic stimulation with two settings: a cut-off for acoustic amplification at the frequency where thresholds exceeded 70 dB and 85 dB. An overlapping setting was also tried in five participants. Results: There was a non-significant trend with a median improvement in SRT of 1.3 dB (70 dB cut-off) and 0.8 dB (85 dB cut-off) compared to the electric only condition. From nine subjects who completed the study, one preferred the 85 dB cut-off frequency, with the others preferred either a 70 dB cut-off or an overlapping setting. Discussion: Nine subjects continued to use the EAS processor after study termination because of subjective benefits. The variability in speech outcomes and subjective preference is underlining the importance of being able to manually change acoustic and electric cut-off frequencies. Conclusion: There were non-significant median group benefits from use of the acoustic component for these existing CI users. A hearing loss of 70 dB HL is an appropriate default cut-off frequency in the fitting software.
Background: This study examined electrical bioimpedance as a biomarker for intracochlear tissue changes after cochlear implant surgery, comparing monopolar, three-point, and four-point impedance measurements over time and evaluating different measurement systems and approaches. Methods: Impedance measurements were obtained from 21 participants during surgery and at four postoperative stages. Monopolar impedances were recorded using the Bionic Ear Data Collection System (BEDCS) and the Active Insertion Monitoring (AIM) system. Three- and four-point impedances were recorded directly using BEDCS, and indirect three-point impedances were additionally derived from Electrical Field Imaging matrices recorded using BEDCS or AIM. Results: There was an 11% relative error between monopolar measurements from BEDCS and AIM and a 25% discrepancy between direct and indirect three-point measurements. Despite this, direct and indirect measurements from both systems were useful for tracking postoperative impedance shifts. Three- and four-point measurements showed a strong relationship both during and after surgery. Our results suggest that three- and four-point measurements are more specific than monopolar impedances in capturing localized tissue changes. Conclusions: Three- and four-point impedance measurements are potential markers of intracochlear tissue changes over time. While direct three-point impedance measurements offer higher accuracy, indirect measurements provide a feasible alternative for monitoring intracochlear changes in clinical settings lacking the option of direct measurements.