Climate observations and their applications require measurements with high stability and low uncertainty in order to detect and assess climate variability and trends. The difficulty with space-based observations is that it is generally not possible to trace them to standard calibration references when in orbit. In order to overcome this problem, it has been proposed to deploy space-based radiometric reference systems which intercalibrate measurements from multiple satellite platforms. Such reference systems have been strongly recommended by international expert teams. This paper describes the Chinese Space-based Radiometric Benchmark (CSRB) project which has been under development since 2014. The goal of CSRB is to launch a reference-type satellite named LIBRA in around 2025. We present the roadmap for CSRB as well as requirements and specifications for LIBRA. Key technologies of the system include miniature phase-change cells providing fixed-temperature points, a cryogenic absolute radiometer, and a spontaneous parametric down-conversion detector. LIBRA will offer measurements with SI traceability for the outgoing radiation from the Earth and the incoming radiation from the Sun with high spectral resolution. The system will be realized with four payloads, i.e., the Infrared Spectrometer (IRS), the Earth-Moon Imaging Spectrometer (EMIS), the Total Solar Irradiance (TSI), and the Solar spectral Irradiance Traceable to Quantum benchmark (SITQ). An on-orbit mode for radiometric calibration traceability and a balloon-based demonstration system for LIBRA are introduced as well in the last part of this paper. As a complementary project to the Climate Absolute Radiance and Refractivity Observatory (CLARREO) and the Traceable Radiometry Underpinning Terrestrial- and Helio- Studies (TRUTHS), LIBRA is expected to join the Earth observation satellite constellation and intends to contribute to space-based climate studies via publicly available data.
29 August 2023 in IEEE Transactions on Geoscience and Remote Sensing
Observation sites using standard automated observation equipment and unified processing technology, such as the radiometric calibration network (RadCalNet) and the automated vicarious calibration system (AVCS) for continuous automated observation and independent on-orbit calibration and monitoring, are used to overcome difficulties of traditional vicarious calibration. In this paper, the top of atmosphere (TOA) reflectance measured by five kinds of satellite sensors was used to evaluate the reliability of the AVCS-predicted TOA reflectance. The bidirectional reflectance distribution function (BRDF) model was introduced for observational geometric correction to meet the calibration requirements of sensors with different view angles. The mean relative deviation of the TOA reflectance between the predicted value and the sensor observations was within 3.5% (4.9% in 661.4nm band of ETM+, 6.9% in SWIR2 band). Due to the less radiation performance evaluation of FY-3D MERSI-II in continuous time series, AVCS was used to perform continuous on-orbit calibration application of FY-3D MERSI-II in continuous time series. The results showed that each band had varying degrees of variation, among which the shortwave variation was more than 29%. An update of the calibration coefficient was needed. The consistency of TOA reflectance measured via Aqua MODIS and FY3D MERSI-II after using the gain model was improved to varying degrees compared with the official gain. In the future, AVCS will be applied to the on-orbit calibration and radiation performance evaluation of various sensors, and improvement in the accuracy of the AVCS-predicted TOA reflectance for the band sensitive to water vapor is needed.
In the solar reflective band, an on-board calibration method based on a solar diffuser (SD) can realize full aperture, full field of view, and end-to-end absolute radiometric calibration of optical remote sensors. The SD’s bidirectional reflectance distribution function (BRDF) is a key parameter that affects the accuracy of the on-board calibration. High-accuracy measurement of the SD BRDF is required in the laboratory before launch. Due to the uncertainty of the goniometer system, polarization effects, and other factors, the measurement uncertainty of the SD BRDF at large incident angles is much higher than that at a 0° incident zenith angle and 45° reflection zenith angle. In this paper, an absolute BRDF measurement facility is reported. The goniometric system consists of a high-brightness integrating sphere as a radiation source, a six-axis robot arm, and a large rotation stage. The measurement wavelength range was from 350 nm to 2400 nm. An improved data processing method based on the reciprocity theorem was proposed to reduce the measurement uncertainty of the SD BRDF at large incident angles. At an incident zenith angle of 75°, the improved data processing method reduced the measurement uncertainty of the SD BRDF by 52% at 410 nm to 480 nm, by 70% at 480 nm to 1000 nm, and by 20% at other bands compared to the absolute measurement method. The influence of the radiation source, goniometer system, detection system, and other factors on the measurement uncertainty are analyzed in this paper. The results show that the measurement uncertainty (coverage factor k = 2) of the SD BRDF was better than 1.04% at 350 nm to 410 nm, 0.60% at 410 nm to 480 nm, 0.43% at 480 nm to 1000 nm, and 0.86% at 1000 nm to 2400 nm.
To calibrate the low signal response of the ocean color (OC) bands and test the stability of the Fengyun-3D (FY-3D)/Medium Resolution Spectral Imager II (MERSI-II), an absolute radiometric calibration field test of FY-3D/MERSI-II at the Lake Qinghai Radiometric Calibration Site (RCS) was carried out in August 2018. The lake surface and atmospheric parameters were mainly measured by advanced observation instruments, and the MODerate spectral resolution atmospheric TRANsmittance algorithm and computer model (MODTRAN4.0) was used to simulate the multiple scattering radiance value at the altitude of the sensor. The results showed that the relative deviations between bands 9 and 12 are within 5.0%, while the relative deviations of bands 8, and 13 are 17.1%, and 12.0%, respectively. The precision of the calibration method was verified by calibrating the Aqua/Moderate-resolution Imaging Spectroradiometer (MODIS) and National Polar-orbiting Partnership (NPP)/Visible Infrared Imaging Radiometer (VIIRS), and the deviation of the calibration results was evaluated with the results of the Dunhuang RCS calibration and lunar calibration. The results showed that the relative deviations of NPP/VIIRS were within 7.0%, and the relative deviations of Aqua/MODIS were within 4.1% from 400 nm to 600 nm. The comparisons of three on-orbit calibration methods indicated that band 8 exhibited a large attenuation after launch and the calibration results had good consistency at the other bands except for band 13. The uncertainty value of the whole calibration system was approximately 6.3%, and the uncertainty brought by the field surface measurement reached 5.4%, which might be the main reason for the relatively large deviation of band 13. This study verifies the feasibility of the vicarious calibration method at the Lake Qinghai RCS and provides the basis and reference for the subsequent on-orbit calibration of FY-3D/MERSI-II.
We propose a space benchmark sensor with onboard SI (Système International) traceability by means of quantum optical radiometry. Correlated photon pairs generated by spontaneous parametric down-conversion (SPDC) in nonlinear crystals are used to calibrate the absolute responsivity of a solar observing radiometer. The calibration is systematic, insensitive to degradation and independent of external radiometric standards. Solar spectral irradiance at 380–2500 nm is traceable to the photon rate and Planck’s constant with an expected uncertainty of about 0.35%. The principle of SPDC calibration and a prototype design of the solar radiometer are introduced. The uncertainty budget is analyzed in consideration of errors arising from calibration and observation modes.
20 January 2020 in The European Physical Journal D