Janusz W Strzelecki

Dr. Janusz W Strzelecki

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2013 in Thin Solid Films
Verified
Journal Article
Closed access
AZA. Zawadzka
A. Zawadzka
PPP. Płóciennik
P. Płóciennik
JSJanusz W Strzelecki
Janusz W Strzelecki
MPM. Pranaitis
M. Pranaitis
SDSylvie Dabos-Seignon
Sylvie Dabos-Seignon
Bouchta SahraouiBouchta Sahraoui
Bouchta Sahraoui

1 February 2014 in Dyes and Pigments
Verified
Journal Article
Closed access
AZA. Zawadzka
A. Zawadzka
PPP. Płóciennik
P. Płóciennik
JSJanusz W Strzelecki
Janusz W Strzelecki
AKA. Korcala
A. Korcala
AAA.K. Arof
A.K. Arof
Bouchta SahraouiBouchta Sahraoui
Bouchta Sahraoui

1 September 2018 in Micron
Verified
Journal Article
Closed access
DLDariusz Laskowski
Dariusz Laskowski
JSJanusz W Strzelecki
Janusz W Strzelecki
Konrad Wiesław PawlakKonrad Wiesław Pawlak
Konrad Wiesław Pawlak
HDHanna Dahm
Hanna Dahm
ABAleksander Balter
Aleksander Balter

18 June 2013 in Optical and Quantum Electronics
Verified
Journal Article
Closed access
PDF file
Anna ZawadzkaAnna Zawadzka
Anna Zawadzka
PPP. Płóciennik
P. Płóciennik
JSJanusz W Strzelecki
Janusz W Strzelecki

24 May 2014 in Journal of Solid State Electrochemistry
Verified
Journal Article
Open access
PDF file
Paweł SzroederPaweł Szroeder
Paweł Szroeder
NTNikos G. Tsierkezos
Nikos G. Tsierkezos
MWMariusz Walczyk
Mariusz Walczyk
WSWłodzimierz Strupiński
Włodzimierz Strupiński
AGAgnieszka Górska-Pukownik
Agnieszka Górska-Pukownik
URUwe Ritter
Uwe Ritter
Electrocatalytic activity of graphene grown epitaxially on SiC is studied using cyclic voltammetry and electrochemical impedance spectroscopy. AFM images show step-like topography of SiC-graphene. For ferri-/ferrocyanide redox couple, no voltammetric response is observed at the pristine graphene. Basal planes of graphite are electrochemically inactive as well. After electrochemical oxidation, apparent redox peaks appear at both the graphene and graphite electrode. However, more intensive redox peaks are observed at graphene, where simultaneous redox reaction with the adsorbed and the diffused ferri-/ferrocyanide ions occurs. Electrochemical impedance measurements show that the graphene electrode behaves like an array of microelectrodes. We used the partially blocked electrode model to fit impedance data. Using the fitting parameters, a size of microelectrodes was found to be 23.8 ± 2.1 μm and the active surface of graphene was estimated to be 21 %. A value of the standard electron transfer rate constant found for the anodized epitaxial graphene (2.16 ± 0.32) × 10− 3cm ⋅ s− 1) is by one order of magnitude lower than the standard rate constant estimated for the anodized graphite basal planes (∼5 × 10− 2cm ⋅ s− 1). Electrochemical reduction causes total disappearance of electrochemical responses at the graphene electrode, whereas only slight decrease of the peak currents is observed at the reduced graphene. Such behavior proves that different activation mechanisms occur at the graphene and graphite electrodes.

1 May 2015 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
MTM. Tszydel
M. Tszydel
AZAgnieszka Zabłotni
Agnieszka Zabłotni
DCDorota Cibor
Dorota Cibor
MMM. Michalak
M. Michalak
IKI. Krucińska
I. Krucińska
JSJanusz W Strzelecki
Janusz W Strzelecki