Superconducting electric motors are required in order to deliver lower-carbon aviation. Critical to the success and viability of operating superconducting electric motors in aviation is keeping the superconducting coils at their operating temperature. This paper examines the challenges of keeping a superconducting motor cold if it were used on a single aisle passenger aircraft such as an Airbus A320. The cooling problem is defined and different cooling scenarios are investigated to determine viability. The investigation has shown that for a motor with a superconducting rotor only (copper stator), a Stirling-type cryocooler would be sufficient. However, if the motor is to be fully superconducting, then the cooling loads of the stator, which are much higher, make mechanical refrigeration impractical and the only option is to cool the motor with the heat sink of a liquid hydrogen fuel.
Superfluid at 2 K or below is readily obtained from liquid helium at 4.2 K by reducing its vapour pressure. For better cooling performance, however, the cold energy of vaporized helium at 2 K chamber can be effectively utilized in a recuperator which is specially designed in this paper for accomplishing so-called the distributed Joule-Thomson (JT) expansion effect. This paper describes the design methodology of distributed JT effect heat exchanger for 2 K JT cooling device. The newly developed heat exchanger allows continuous significant pressure drop at high-pressure part of the recuperative heat exchanger by using a capillary tube. Being different from conventional recuperative heat exchangers, the efficient JT effect HX must consider the pressure drop effect as well as the heat transfer characteristic. The heat exchanger for the distributed JT effect actively utilizes continuous pressure loss at the hot stream of the heat exchanger by using an OD of 0.64 mm and an ID of 0.4 mm capillary tube. The analysis is performed by dividing the heat exchanger into the multiple sub-units of the heat exchange part and JT valve. For more accurate estimation of the pressure drop of spirally wound capillary tube, preliminary experiments are carried out to investigate the friction factor at high Reynolds number. By using the developed pressure drop correlation and the heat transfer correlation, the specification of the heat exchanger with distributed JT effect for 2 K JT refrigerator is determined.
28 February 2020 in IEEE Transactions on Applied Superconductivity
A conduction-cooled HTS magnet was tested to produce an AC magnetic field up to 4 T for an adiabatic demagnetization refrigerator (ADR). Quench detection was conducted by measuring the voltages in the conductor, and the protection system was constructed with an external dump resistor. The magnet, which is equipped with extensive copper thermal drains, was conduction-cooled by a two-stage Gifford-McMahon cryocooler to approximately 6 K. The magnet succeeded to stably generate an alternating magnetic field between 0 and 3.5 T at a ramp rate of 229 mT/s without any pre-quench signs; however, in the case of a maximum 4 T experiment, a quench occurred, and the magnet was permanently damaged. The quench location was identified as the place where the highest perpendicular field from the magnet was generated. It is speculated that the already-formed normal zone before quench grows very fast during the dump process, and the part of the magnetic energy is dissipated in this normal zone, causing the excessive temperature rise of the conductor. The detailed experimental results are presented and discussed.