Yongchao Chen

Dr. Yongchao Chen

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2020 in Optics Express
Verified
Journal Article
Closed access
JHJingwei Huang
Jingwei Huang
YCYongchao Chen
Yongchao Chen
QSQiuheng Song
Qiuheng Song
HPHekuo Peng
Hekuo Peng
PZPengwei Zhou
Pengwei Zhou
BJBo Jia
Bo Jia
A novel distributed fiber-optic sensor is proposed and demonstrated, in which two Mach-Zehnder interferometers are used to detect the interference signals with different wavelengths, and one 3 × 3 coupler is deployed to demodulate the time-varying phase change caused by vibration. The novel dual Mach-Zehnder interferometer (DMZI) is composed of two wavelength division multiplexers. Then, a time delay estimation algorithm is designed to construct two related signals using the phase difference, and the two constructed signals are used to obtain vibration position through cross-correlation. Experimental results show that the sensing distance can reach 100 km and the location error is within ±25 m.

8 February 2024 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
SSSijin Shen
Sijin Shen
YLYali Li
Yali Li
YDYunxia Dong
Yunxia Dong
JHJidong Hu
Jidong Hu
YCYongchao Chen
Yongchao Chen
JLJunshuai Li
Junshuai Li

1 January 2021 in Optics Communications
Verified
Journal Article
Closed access
JHJingwei Huang
Jingwei Huang
YCYongchao Chen
Yongchao Chen
HPHekuo Peng
Hekuo Peng
PZPengwei Zhou
Pengwei Zhou
QSQiuheng Song
Qiuheng Song
BJBo Jia
Bo Jia

25 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YSYifei Sun
Yifei Sun
YCYongchao Chen
Yongchao Chen
Longhuang TangLonghuang Tang
Longhuang Tang
XJXing Jia
Xing Jia
HMHeli Ma
Heli Ma
JWJidong Weng
Jidong Weng
An ultrafast microwave ranging method based on optically generated frequency-modulated microwave pulses is proposed in this study. The theoretical analysis demonstrated that nanosecond-scale linear frequency modulation microwave pulse can be obtained by femtosecond laser interference under the condition of unbalanced dispersion, which can be used to achieve a high temporal resolution of the displacement change in the measurement by the principle of frequency modulation continuous wave (FMCW) radar. The proof-of-principle experiment successfully measured the displacement change with an error of 2.5 mm and a range of 0.6 m, with a response time of 468 ns. Compared to existing microwave ranging technologies, the temporal resolution was improved by two orders of magnitude, which greatly improves the temporal resolution of distance measurement in the field of microwave FMCW radar.

15 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Longhuang TangLonghuang Tang
Longhuang Tang
XJXing Jia
Xing Jia
HMHeli Ma
Heli Ma
SLShenggang Liu
Shenggang Liu
YCYongchao Chen
Yongchao Chen
JWJidong Weng
Jidong Weng
A microwave absolute distance measurement method with ten-micron-level accuracy and meter-level range based on frequency domain interferometry is proposed and experimentally demonstrated for the first time. Theoretical analysis indicates that an interference phenomenon occurs instantaneously in the frequency domain when combining two homologous broad-spectrum microwave beams with different paths, and the absolute value of the distance difference between the two paths is only inversely proportional to the period of frequency domain interference fringes. The proof-of-principle experiments were performed to prove that the proposed method can achieve absolute distance measurement in the X-band with standard deviations of 15 μm, 17 μm, and 26 μm and within ranges of 1.69 m, 2.69 m, and 3.75 m. Additionally, a displacement resolution of 100 microns was realized. The multi-target recognition performance was also verified in principle. Furthermore, at the expense of a slight decrease in ranging accuracy, a fast distance measurement with the single measurement time of 20 μs was achieved by using a digitizer combined with a Fourier transform analyzer. Compared with the current microwave precision ranging technologies, the proposed method not only has the advantages of high precision, large range, and rapid measurement capability, but the required components are also easily obtainable commercial devices. The proposed method also has better complex engineering applicability, because the ten-micron-level ranging accuracy is achievable only by using a simple Fourier transform without any phase estimation algorithm, which greatly reduces the requirement for signal-to-noise ratio.

15 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
YCYongchao Chen
Yongchao Chen
TLTianci Liu
Tianci Liu
SLShenggang Liu
Shenggang Liu
Longhuang TangLonghuang Tang
Longhuang Tang
HMHeli Ma
Heli Ma
JWJidong Weng
Jidong Weng
This paper proposes a technique for precise distance measurement under laser random noise using autocorrelation demodulation. We conducted measurements within a 2 m range using a commercial digitizer with a sampling rate of 40 GS/s. The single signal acquisition time is 40 μs, and the measurement results achieved an accuracy of 30 μm and a standard deviation (SD) of 8 μm. This method can also improve measurement accuracy by increasing the sampling rate and expanding the measurement range by extending the duration of a single sampling.