Over the last decade, many power systems have significantly changed with the proliferation of renewable generation sources, such as wind and solar photovoltaic. Due to their variability and nonsynchronous nature, new challenges and complexities have emerged regarding operational security of modern power systems. The 2016 South Australia (SA) blackout was the first known blackout due to such a high renewable situation. An official report has recently been published to review the causes and provide the corresponding recommendations for improvement of network operation, control, and security. However, there are still a number of critical issues and debates which remain unsolved, such as network bottleneck identification, overvoltage explanation, pole slip concern, frequency dip mystery, and frequency/voltage instability debate. In this paper, based on the reconstruction of the event, these unsettled issues are prudently analyzed to unveil their root causes. In addition, an innovative scheme is proposed to prevent the blackout by identifying the network separation at an early stage. This research will not only further advance the understanding of the 2016 SA blackout, but also will provide valuable guidelines for the management of future renewable-rich networks.
5 January 2018 in IEEE Transactions on Power Systems
There are more large-scale PV plants being established in rural areas due to availability of low priced land. However, distribution grids in such areas traditionally have feeders with low X/R ratios, which makes the independent reactive power compensation method less effective on voltage regulation. Consequently, upstream Step Voltage Regulator (SVR) may suffer from excessive tap operations with PV induced fast voltage fluctuations. Although a battery energy storage system (BESS) can successfully smooth PV generation, frequent charge/discharge will substantially affect its cost effectiveness. In this paper, a real-time method is designed to coordinate PV inverters and BESS for voltage regulation. To keep up with fast fluctuations of PV power, this method will be executed in each 5s control cycle. In addition, charging/discharging power of BESS is adaptively retuned by an active adjustment method in order to avoid BESS premature energy exhaustion in a long run. Finally, through a voltage margin control scheme, the upstream SVR and downstream PV inverters and BESS are coordinated for voltage regulation without any communication. This research is validated via an RTDS-MatLab co-simulation platform, and it will provide valuable insights and applicable strategies to both utilities and PV owners for large-scale PV farm integration into rural networks.
31 January 2012 in IEEE Transactions on Power Systems
Several studies on voltage stability analysis of electric systems with high photovoltaic (PV) penetration have been conducted at a power-transmission level, but very few have focused on small-area networks of low voltage. As a distribution system has its special characteristics-high R/X ratio, long tap switching delay, small PV units, and so on-PV integration impacts also need to be investigated thoroughly at a distribution level. In this paper, the IEEE 13 bus system has been modified and extended to explore network stability impacts of variable PV generation, and the results show that a voltage stability issue with PV integration does exist in distribution networks. Simulation comparisons demonstrate that distribution networks are traditionally designed for heavily loaded situations exclusive of PVs, but they can still operate under low PV penetration levels without cloud-induced voltage-stability problems. It is also demonstrated that voltage instability can effectively be solved by PV inverter reactive power support if this scheme is allowed by the standards in the near future.
27 June 2017 in IEEE Transactions on Power Systems
The installed capacity of wind generation and photovoltaics (PV) in many countries is going to dominate generation fleets in a bid to meet growing renewable energy targets. Synchronous inertia has never been problematic as there was more available than needed, but it is being significantly reduced due to the increasing integration of non-synchronous renewable generation. When the low bidding priced generation of wind and PV becomes considerably large, conventional economic dispatch algorithms can result in less online synchronous inertia and put power system security at risk. However, the compromise of power system security due to synchronous inertia shortage is not well studied in literature. This paper develops a synchronous inertia constrained economic dispatch algorithm to satisfy the minimum required synchronous inertia of frequency control. Synchronous condensers and wind reserve are economically allocated to alleviate any shortage of synchronous inertia and frequency control ancillary services (FCAS). A Gaussian particle swarm optimization algorithm is introduced to simultaneously co-optimize the dispatch of synchronous generators and their FCAS, wind reserve and synchronous condensers.
In a geographically small distribution area, fast moving clouds may cover the whole area within a short period causing photovoltaic (PV) power to drop. When a feeder loses PV power support, bus voltages will decrease. In an unbalanced network, asymmetrical spacing and non-transposition of line configurations can result in different voltage drops for each phase. This may potentially cause some voltage problems after a decline in PV generation, such as an extremely low voltage magnitude of a certain phase and an unacceptable voltage imbalance level at a remote bus. This paper proposes a method of analyzing voltage variation sensitivity due to PV power fluctuations in an unbalanced network (unbalanced line configuration and phase loading levels). Based on this method, a network reconfiguration solution is developed to solve the voltage problems. This solution utilizes unbalanced line characteristics and realizes the potential of the network, so no extra compensation devices are needed for network support.