Koki Abe

Dr. Koki Abe

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in Journal of Molecular and Cellular Cardiology
Verified
Journal Article
Closed access
YTYuki Tatekoshi
Yuki Tatekoshi
MTMasaya Tanno
Masaya Tanno
HKHidemichi Kouzu
Hidemichi Kouzu
KAKoki Abe
Koki Abe
TMTakayuki Miki
Takayuki Miki
TMTetsuji Miura
Tetsuji Miura

17 December 2020 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
FYFan Yang
Fan Yang
HCHyonmin Choe
Hyonmin Choe
NKNaomi Kobayashi
Naomi Kobayashi
TTTaro Tezuka
Taro Tezuka
MOMasatoshi Oba
Masatoshi Oba
YIYutaka Inaba
Yutaka Inaba

3 March 2022 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
KAKoki Abe
Koki Abe
MOMasatoshi Oba
Masatoshi Oba
NKNaomi Kobayashi
Naomi Kobayashi
SHShota Higashihira
Shota Higashihira
HCHyonmin Choe
Hyonmin Choe
YIYutaka Inaba
Yutaka Inaba
Background: Precise osteochondroplasty is important in arthroscopic hip surgery for cam-type femoroacetabular impingement (FAI). Although computer-assisted surgery with a navigation system may enhance the accuracy of arthroscopic osteochondroplasty, few clinical studies have assessed its accuracy. Purpose: To evaluate the accuracy of arthroscopic osteochondroplasty by a computed tomography (CT)–based navigation system for cam-type FAI, using 3-dimensional (3D) reconstruction with more detail compared with previous methods. Study design: Case series; Level of evidence, 4. Methods: Twenty patients (14 men and 6 women) who underwent navigation-assisted arthroscopic surgery for cam-type FAI were included. The preoperative 3D model of the femur was constructed from each patient’s CT data, and a planned model with virtual cam resection was generated. A femoral model was reconstructed from CT data postoperatively. The 3 models for each patient were overlaid using a 3D model registration method. Then, the contours of the bone resection area of each model were compared by measuring them. To measure the deviation between planned and actual bone resections, 4 cross-sectional images of the 3 femoral models were set at one-quarter intervals from the femoral head radius. All measurements were based on clockface lines set around the femoral neck axis at 30-minute intervals. Differences between the planned and postoperative contour lines were deemed resection deviations. Results: All cam resections were performed in the anterior half of the region of interest. Therefore, only the anterior half (48 points) of the 96 points per case were analyzed. In 876 (91.3%) points of the total measurement points (960 points/20 cases), the error in resection depth was within 3 mm. Overresection was observed at 35 (3.6%) points and underresection at 49 (5.1%) points. The observed maximum deviations from the planned models were 6.3 mm overresection and –7.1 mm underresection. The alpha angles of the postoperative model at the posterior 9- to 3-o’clock position were <55° in all patients. Conclusion: Navigation-assisted arthroscopic osteochondroplasty showed favorable accuracy. Underresection was more frequent than overresection on the anterosuperior side of the femur, despite assistance of the navigation system.

13 May 2024 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
YHYuta Hieda
Yuta Hieda
HCHyonmin Choe
Hyonmin Choe
HIHiroyuki Ike
Hiroyuki Ike
KAKoki Abe
Koki Abe
KKKen Kumagai
Ken Kumagai
YIYutaka Inaba
Yutaka Inaba

26 August 2025 in SICOT-J
Verified
Journal Article
Open access
PDF file
ABA. Mounir Boudali
A. Mounir Boudali
JSJobe Shatrov
Jobe Shatrov
KAKoki Abe
Koki Abe
MZMarcus Zavala
Marcus Zavala
DPDavid Parker
David Parker
ECElizabeth Clarke
Elizabeth Clarke
Introduction: Complications arising from the patellofemoral joint (PFJ) represent the third most common cause for revision in total knee arthroplasty (TKA). Previous in vitro biomechanical studies have altered the native attachments of muscles controlling the PFJ. The purpose of this study was to design an in vitro biomechanical setup that would allow testing of both native and arthroplasty knee joints, specifically the PFJ, without disturbing the native attachments of the quadriceps and hamstrings muscles. Methods: After finalising a prototype, a pelvis-to-toe human cadaver specimen was tested. The simVITRO platform was used to simulate movement and control force trajectories. A motion capture system was used to capture the motion of the bones and to measure knee flexion angle and patellar movement with respect to the femur. The forces applied in the PFJ were measured using a custom patella sensor. Results: Displacement of the reflective cluster attached to the femur was measured during compression loading at different flexion angles, passive flexion and stairs descent trajectory. The femur showed less than 1 mm and 3 mm displacement with respect to the femur clamp in passive flexion and stairs descent. The most translation of 8.37 mm (<2% average femur length) was observed at 90° flexion which occurred at 483 N simulated compression force. Conclusion: This novel design provides a methodology for studying the biomechanics of the PFJ in vitro that preserves the soft tissues influencing the behaviour of the joint. This setup provides a biomechanics model that can be utilised to better understand and study the PFJ in vitro.

25 August 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HMHIDEO MITSUI
HIDEO MITSUI
HCHyonmin Choe
Hyonmin Choe
MSMasashi Shimoda
Masashi Shimoda
HYHironori Yamane
Hironori Yamane
YHYuta Hieda
Yuta Hieda
YIYutaka Inaba
Yutaka Inaba
Background: Serum markers are commonly used to diagnose bone and joint infections; however, their accuracy for diagnosing pyogenic spondylitis remains unproven. This study aimed to validate the diagnostic accuracy of inflammatory, nutritional, and immunological serum markers for spinal infections and identify the most effective combinations. Methods: The retrospective cohort study analyzed 656 patients who visited the hospital for spinal diseases between 1 January 2004 and 31 March 2021; a total of 76 were diagnosed with pyogenic spondylitis. Blood samples were analyzed for serum albumin (Alb), total protein (TP), globulin (Glb), C-reactive protein (CRP), platelet count, white blood cell count, neutrophil count, lymphocyte count, and monocyte count. Combination markers, including albumin–globulin ratio (AGR), CRP–albumin ratio (CAR), CRP–AGR (CAGR), neutrophil–lymphocyte ratio (NLR), and platelet–lymphocyte ratio (PLR), were also evaluated. Receiver operating characteristic curves were used to determine each marker’s diagnostic performance. Furthermore, multivariate analysis was performed to examine the odds ratios. Results: Patients with pyogenic spondylitis showed significantly different levels in Alb (p < 0.0001), Glb (p < 0.0001), CRP (p < 0.0001), platelet count (p < 0.0001), WBC count (p < 0.0006), neutrophil count (p = 0.0019), lymphocyte count (p = 0.0085), AGR (p < 0.0001), CAR (p < 0.0001), CAGR (p < 0.0001), NLR (p < 0.0001), and PLR (p < 0.0001). CRP (AUC = 0.80) showed good diagnostic accuracy, while combination markers CAR (AUC = 0.82) and CAGR (AUC = 0.83) had the highest areas under the curve (AUC). Multivariate analysis indicated that decreased age and the presence of comorbidities (including chronic kidney disease, chronic liver disease, malignancy, or diabetes), were independent predictors of early pyogenic spondylitis (OR_age = 0.93, OR_comorbidities = 16.98, p_age = 0.0005, and p_comorbidities = 0.0001). In patients with low-inflammatory pyogenic spondylitis, significant differences were observed in TP (p = 0.0293), Glb (p = 0.0012), CRP (p = 0.0023), platelet count (p = 0.0108), AGR (p = 0.0044), CAR (p = 0.0006), CAGR (p = 0.0004), PLR (p = 0.0192), and NLR (p = 0.0027), with CAGR showing the highest AUC (AUC = 0.70) among them. Conclusions: Serum combination markers (AGR, CAGR, CAR, PLR, and NLR) showed diagnostic value for pyogenic spondylitis, with CAGR achieving the highest accuracy. In low-inflammatory pyogenic spondylitis patients (CRP ≤ 1.0 mg/dL), these markers may aid diagnosis.