Ahmed Mounir Boudali

Ahmed Mounir Boudali

Auto-generated profile, based on publicly available information

Ahmed Mounir Boudali

Murray Maxwell Biomechanics Laboratory, Kolling Institute, Northern Sydney Local Health District, 10 Westbourne St, St Leonards, NSW 2065, Australia

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
ABA. Mounir Boudali
A. Mounir Boudali
PSPeter J. Sinclair
Peter J. Sinclair
IMIan R. Manchester
Ian R. Manchester
In recent years, wearable exoskeletons and powered prosthetics have been considered key elements to remedy mobility loss. One of the main challenges pertaining to this field is the prediction of the wearer’s desired motion. In this paper, we perform a human locomotion analysis, and we investigate the accuracy of predicting the angular position of the lower limb joints from the motion of walking canes. Nine healthy subjects took part of this study and performed a locomotor task that comprised straight walking on flat ground, stair ascent, and upright resting posture. Recurrent Neural Networks and polynomial fitting using Least Squares were used to model dynamic and static non-linear mappings, respectively, between the motion of a cane and its contra-lateral leg joints. A successful prediction of both the hip and knee joints was achieved using information from the cane only, and significant improvement of the prediction error was realized through the addition of data from the arm joints. Overall, Recurrent Neural Networks outperformed Least Squares for both joints’ angular position prediction. When using the cane only, the static maps were able to predict steady behaviour but failed in predicting transitioning, as opposed to RNN, which was able to capture both steady behaviour and transitions.

1 November 2019
Verified
Conference Paper
Closed access
Abdullah AL-AZZAWIAbdullah AL-AZZAWI
Abdullah AL-AZZAWI
ABA. Mounir Boudali
A. Mounir Boudali
HKHe Kong
He Kong
AGAli H. Goktogan
Ali H. Goktogan
SSSalah Sukkarieh
Salah Sukkarieh
Soft strain resistive sensors based on eutectic gallium-indium liquid metal can play an important role in proprioceptive sensing for soft robots. However, there are no available mathematical models to accurately estimate the strain as a function of the measured resistance. Furthermore, non-uniform strain in the microchannels has not been analysed yet. In this paper, we introduce a new model to estimate the strain or elongation in sub-millimetre scale, and analyse its accuracy through a customised testing set-up and procedure. The effect of strain rate on the measurement accuracy is also studied. We compare existing theoretical models with our experimental results, and discuss the differences between them. Moreover, we analyse the effect of strain rate on hysteresis caused by the viscoelastic behaviour and introduce a new model for it to be potentially used for future work. This paper demonstrates, among other things, that rational models could provide high accuracy in strain estimation, and might help to enhance proprioceptive sensing and state control of soft robots.

26 August 2025 in SICOT-J
Verified
Journal Article
Open access
PDF file
ABA. Mounir Boudali
A. Mounir Boudali
JSJobe Shatrov
Jobe Shatrov
KAKoki Abe
Koki Abe
MZMarcus Zavala
Marcus Zavala
DPDavid Parker
David Parker
ECElizabeth Clarke
Elizabeth Clarke
Introduction: Complications arising from the patellofemoral joint (PFJ) represent the third most common cause for revision in total knee arthroplasty (TKA). Previous in vitro biomechanical studies have altered the native attachments of muscles controlling the PFJ. The purpose of this study was to design an in vitro biomechanical setup that would allow testing of both native and arthroplasty knee joints, specifically the PFJ, without disturbing the native attachments of the quadriceps and hamstrings muscles. Methods: After finalising a prototype, a pelvis-to-toe human cadaver specimen was tested. The simVITRO platform was used to simulate movement and control force trajectories. A motion capture system was used to capture the motion of the bones and to measure knee flexion angle and patellar movement with respect to the femur. The forces applied in the PFJ were measured using a custom patella sensor. Results: Displacement of the reflective cluster attached to the femur was measured during compression loading at different flexion angles, passive flexion and stairs descent trajectory. The femur showed less than 1 mm and 3 mm displacement with respect to the femur clamp in passive flexion and stairs descent. The most translation of 8.37 mm (<2% average femur length) was observed at 90° flexion which occurred at 483 N simulated compression force. Conclusion: This novel design provides a methodology for studying the biomechanics of the PFJ in vitro that preserves the soft tissues influencing the behaviour of the joint. This setup provides a biomechanics model that can be utilised to better understand and study the PFJ in vitro.

13 August 2024 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
TCThomas Clifton
Thomas Clifton
AAAdil S. Ahmed
Adil S. Ahmed
RPRobert P. Piggott
Robert P. Piggott
ECElizabeth Clarke
Elizabeth Clarke
ABAhmed Mounir Boudali
Ahmed Mounir Boudali
AYAllan A. Young
Allan A. Young