This paper presents the results of an analysis focused on the behavior of emittance, energy spread and radiated power, as well as their variations in relation to the complement of active insertion devices in National Synchrotron Light Source II (NSLS-II) operations. The spectra of radiated power of the installed insertion devices and analytic values of the emittance are compared to that measured by the NSLS-II online diagnostics. A conceptual design of a compensation wiggler that will maintain a constant emittance or energy spread is investigated for NSLS-II and a potential low emittance upgrade scenario.
17 December 2019 in Physical Review Accelerators and Beams
NSLS-II is now one of the brightest synchrotron light sources worldwide, in user operations since 2014. Currently, 20 light-generating insertion devices (IDs) are installed: 3 damping wigglers and 17 undulators of various types. These devices introduce significant distortions into the magnet lattice of the storage ring. For each ID, the distortions have been locally corrected using quadrupole magnets located nearby the ID. The insertion devices have also a significant impact on the electron beam emittance. Precise measurements of the emittance were carried out at the Coherent Hard X-ray beamline for three different lattices: without IDs, with 3 pairs of damping wigglers only, and with all IDs. A minimum horizontal emittance of 0.76 nm was achieved. The radiation energy loss and relative energy spread were also measured using a streak-camera. The measured data show good agreement with analytical formulas and numerical simulations.
The High energy Engineering X-ray (HEX) diffraction beamline at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL) is the first high-energy beamline capable of reaching 200 keV for a monochromatic beam. With the 3 GeV electron beam energy for the NSLS-II ring, only the superconducting wiggler (SCW) producing greater than 4 T peak field can cover these ranges with a sufficient number of photons. The 1.2 m-long HEX-SCW has a period length of 70 mm and a field strength on-axis of 4.3 T. It utilizes no liquid helium, and the vertical aperture size of the electron beam vacuum chamber is 8 mm. Unlike regular undulators/wigglers, there is no standard configuration for the magnetic measurement system for superconducting insertion devices. The NSLS-II Insertion Devices group has developed, in collaboration with the vacuum group, a novel in-vacuum Hall mapper with a 1.75 m in-vacuum linear motor and an in-vacuum flip coil system utilizing many commercial-off-the-shelf products. The measurements were conducted at the BNL, and the device was installed in the ring and commissioned. This paper provides a description of the SCW and its magnetic measurement systems, as well as a brief account of the installation and commissioning efforts.
6 May 2022 in IEEE Transactions on Applied Superconductivity
With the 3 GeV electron beam energy for the National Synchro-tron Light Source II (NSLS-II) ring, only superconducting wig-glers (SCW) producing greater than 4T peak field can cover the photon energy range of 20keV and 200keV with sufficient num-ber of photons. The High energy Engineering X-ray (HEX) Dif-fraction beamline, which is primarily funded by the New York State Energy Research and Development Authority (NYSERDA) and NSLS-II, will be equipped with a 1.2m-long SCW with 70mm period length and 4.3T on-axis field. This SCW is free from the use of liquid Helium and is cooled only with cryo-coolers. The Electron Beam Chamber (EBC) with vertical aper-ture of 8mm is made from 316LN stainless steel and copper plat-ing is applied both entire upper surface and +- 12.5mm wide from the center in the inner surface. The expected heat load from the electron beam of the NSLS-II ring is estimated to be 10W/m. This paper describes the design principles and engineering chal-lenges for the device.