Saeed Zaman Jamali

Saeed Zaman Jamali

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
CNChul-Ho Noh
Chul-Ho Noh
CKChul-Hwan Kim
Chul-Hwan Kim
GGGi-Hyeon Gwon
Gi-Hyeon Gwon
MKMuhammad Omer Khan
Muhammad Omer Khan
SJSaeed Zaman Jamali
Saeed Zaman Jamali

4 February 2018 in Energies
Verified
Journal Article
Open access
PDF file
MKMuhammad Omer Khan
Muhammad Omer Khan
SJSaeed Zaman Jamali
Saeed Zaman Jamali
CNChul-Ho Noh
Chul-Ho Noh
GGGi-Hyeon Gwon
Gi-Hyeon Gwon
CKChul-Hwan Kim
Chul-Hwan Kim
With the recent developments in power electronics technologies, increased deployment of distributed energy resources (DER) with DC output type at distribution voltage levels and significant increase in the number of sensitive AC and DC loads integrated in distribution network have enforced the traditional power network in the continuous renovation process. In this paper, the load flow solution of hybrid AC/DC distribution networks with the multi-terminal configuration is studied. The impact of voltage source converter (VSC) losses and AC and DC line losses in the presence of DER in the distribution system are assessed. The motivation of this analysis is to consider an increase in the number of converter stations which might result in non-negligible converter losses and the presence of various DER within the network imposing different network scenarios. The proposed schemes are simulated on two modified IEEE 33 bus hybrid AC/DC distribution network test system equipped with VSC-MTDC and the results are presented. Obtained results show that by considering the network losses and the converter losses with large number of converters within the network could lead to very different load flow solution and power transfer between networks, especially considering the AC or DC bus dominated network.

25 November 2019 in Transactions of the Institute of Measurement and Control
Verified
Journal Article
Closed access
PDF file
MMMuhammad Mehdi
Muhammad Mehdi
MSMuhammad Saad
Muhammad Saad
SJSaeed Zaman Jamali
Saeed Zaman Jamali
CKChul-Hwan Kim
Chul-Hwan Kim
The integration of renewable energy resources to DC microgrid has captured the attention of the researchers in recent years. One of the active field of application of DC distribution is the islanded DC microgrid (DC ImG). The DC ImG present numerous challenges to researchers. Among many challenges, the regulation of voltage and stability of the system is indispensable to efficient operation. The voltage stability problem becomes more prominent when the system is exposed to disturbances and possess uncertainties in parameters. However, challenges can be overcome by skilful design of a robust controller for the system. Therefore, in this paper, an output-feedback based centralized robust control scheme is proposed. The proposed controller is designed to maintain good control performance in the presence of parametric uncertainties and exogenous disturbances. The uncertainties of the DC microgrid is modelled as a linear time-varying state-space system. The upper and the lower bounds of the time-varying parameters are determined by a Lebesque-measurable matrix. To attenuate the exogenous disturbances of the system H∞ based output-feedback controller is designed. The system stability is assured by the Lyapunov function candidate. The output-feedback controller needs only the voltage measurement; therefore, it requires less communication bandwidth as compared to the state-feedback. To obtain the controller parameters linear matrix inequality constraints are formulated and solved. The performance of the proposed controller is verified via simulations and compared with the existing schemes.

8 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
SBShazia Baloch
Shazia Baloch
SJSaeed Zaman Jamali
Saeed Zaman Jamali
KMKhawaja Khalid Mehmood
Khawaja Khalid Mehmood
SBSyed Basit Ali Bukhari
Syed Basit Ali Bukhari
MZMUHAMMAD SAEED UZ ZAMAN
MUHAMMAD SAEED UZ ZAMAN
CKChul-Hwan Kim
Chul-Hwan Kim
To resolve the protection issues caused by high penetration of distributed energy resources, this paper proposes an efficient protection scheme for microgrids based on the autocorrelation of three-phase current envelopes. The proposed strategy uses a squaring and low-pass filtering approach for evaluating the envelope of the current signal. Then, the variance of the autocorrelation function is used to extract the hidden information of the distorted envelope to detect the fault signatures in the microgrid. Furthermore, the reactive power is used for determining the fault direction. The performance of the proposed protection scheme was verified on a standard medium-voltage microgrid by performing simulations in the MATLAB/Simulink environment (Version: R2017b). The proposed scheme was shown to be easy to implement and have good performance under looped and radial configuration for both grid-connected and islanded operation modes. The simulation results showed that the scheme could not only detect, locate, classify, and isolate various types of short-circuit faults effectively but also provide backup protection in case of primary protection failure.

28 April 2018 in Energies
Verified
Journal Article
Open access
PDF file
SJSaeed Zaman Jamali
Saeed Zaman Jamali
SBSyed Basit Ali Bukhari
Syed Basit Ali Bukhari
MKMuhammad Omer Khan
Muhammad Omer Khan
MMMuhammad Mehdi
Muhammad Mehdi
CNChul-Ho Noh
Chul-Ho Noh
CKChul-Hwan Kim
Chul-Hwan Kim
A low voltage direct current (LVDC) distribution network is a promising technology to meet the standards of future energy demands for smart loads. An LVDC distribution network can not only supply efficient, smooth and clean energy, but also makes the integration of renewable energy resources in the distribution system easy. A major obstacle in the implementation of the LVDC distribution network is the protection of the network during abnormal grid conditions, such as transients and faults. This paper analyzes DC fault characteristics considering an LVDC distribution network, highlights the worst case scenario during a fault and protection related issues and proposes the protection schemes for the LVDC network. In the proposed protection scheme, a fault is detected and located through superimposed components. To minimize the effect of the DC fault on the distribution network, distributed fault current limiters are introduced and the final decision to disconnect or reconnect the affected line is made on the basis of the type of fault. In addition, a reclosing scheme for a temporary fault is proposed to avoid high inrush currents and false tripping, which eventually increases the reliability. A fast communication-based backup protection is also suggested, and to reduce dependency, a secondary backup is used in the case of communication delay or failure. The proposed scheme is verified using the modified IEEE 13 node test system, which is implemented in ATPDraw. The results show that the proposed scheme can successfully detect, locate and limit a DC fault in an LVDC distribution network with different fault resistances or locations. Moreover, the network is restored successfully in the case of temporary faults.

25 October 2018 in Energies
Verified
Journal Article
Open access
PDF file
SJSaeed Zaman Jamali
Saeed Zaman Jamali
SBSyed Basit Ali Bukhari
Syed Basit Ali Bukhari
MKMuhammad Omer Khan
Muhammad Omer Khan
KMKhawaja Khalid Mehmood
Khawaja Khalid Mehmood
MMMuhammad Mehdi
Muhammad Mehdi
CKChul-Hwan Kim
Chul-Hwan Kim
The day-by-day increase in digital loads draws attention towards the need for an efficient and compatible distribution network. An LVDC distribution network has the capability to fulfill such digital load demands. However, the major challenge of an LVDC distribution network is its vulnerability during a fault. The need for a high-speed fault detection method is inevitable before it can be widely adopted. This paper proposes a new fault detection method which extracts the features of the current during a fault. The proposed fault detection method uses the merits of overcurrent, the first and second derivative of current, and signal processing techniques. Three different features are extracted from a time domain current signal through a sliding window. The extracted features are based upon the root squared zero, second, and fourth order moments. The features are then set with individual thresholds to discriminate low-, high-, and very high-resistance faults. Furthermore, a fault is located through the superimposed power flow. Moreover, this study proposes a new method based on the vector sum of positive and negative pole currents to identify the faulty pole. The proposed scheme is verified by using a modified IEEE 13 node distribution network, which is implemented in Matlab/Simulink. The simulation results confirm the effectiveness of the proposed fault detection and identification method. The simulation results also confirm that a fault having a resistance of 1 m Ω is detected and interrupted within 250 μ s for the test system used in this study.