Syed Basit Ali Bukhari

Dr. Syed Basit Ali Bukhari

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
TGTeke Gush
Teke Gush
SBSyed Basit Ali Bukhari
Syed Basit Ali Bukhari
RHRaza Haider
Raza Haider
SASamuel Admasie
Samuel Admasie
YOYun-Sik Oh
Yun-Sik Oh
CKChul-Hwan Kim
Chul-Hwan Kim

1 November 2017 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
SBSyed Basit Ali Bukhari
Syed Basit Ali Bukhari
MZMUHAMMAD SAEED UZ ZAMAN
MUHAMMAD SAEED UZ ZAMAN
RHRaza Haider
Raza Haider
YOYun-Sik Oh
Yun-Sik Oh
CKChul-Hwan Kim
Chul-Hwan Kim

1 June 2018 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
SBSyed Basit Ali Bukhari
Syed Basit Ali Bukhari
RHRaza Haider
Raza Haider
MZMUHAMMAD SAEED UZ ZAMAN
MUHAMMAD SAEED UZ ZAMAN
YOYun-Sik Oh
Yun-Sik Oh
GCGyu-Jung Cho
Gyu-Jung Cho
CKChul-Hwan Kim
Chul-Hwan Kim

28 February 2020 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
SBSyed Basit Ali Bukhari
Syed Basit Ali Bukhari
CKChul-Hwan Kim
Chul-Hwan Kim
KMKhawaja Khalid Mehmood
Khawaja Khalid Mehmood
RHRaza Haider
Raza Haider
MZMuhammad Saeed Uz Zaman
Muhammad Saeed Uz Zaman
Microgrids experience significantly different fault currents in different operating scenarios, which make microgrid protection challenging. Existing intelligent protection schemes rely on the extraction of appropriate fault features using statistical parameters. The selection of these features is difficult in a microgrid because of its various operating scenarios. This study develops a convolutional neural network‐based intelligent fault protection strategy (CNNBIPS) for microgrids that inherently integrates the feature extraction and classification process. The proposed strategy is directly applicable to three‐phase (TP) current signals; thus, it does not require any separate feature extractor. In the proposed CNNBIPS, TP current signals sampled by the protective relays are used as an input to three different CNNs. The CNNs apply convolution and pooling operations to extract the features from the input signals. Then, fully connected layers of the CNNs employ the features to develop fault‐type, phase, and location information. To analyse the efficacy of the proposed design, we execute exhaustive simulations on a standard microgrid test system. The results confirm the effectiveness of the proposed strategy in terms of detection accuracy, security, and dependability. Moreover, comparisons with previous methods show that the proposed approach outperforms the existing microgrid protection schemes.

27 November 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
RHRAZA HAIDER
RAZA HAIDER
CKChul-Hwan Kim
Chul-Hwan Kim
TGTeymoor Ghanbari
Teymoor Ghanbari
SBSyed Basit Ali Bukhari
Syed Basit Ali Bukhari
MZMUHAMMAD SAEED UZ ZAMAN
MUHAMMAD SAEED UZ ZAMAN
YOYun Sik Oh
Yun Sik Oh
Islanding detection in power systems poses a challenge that can result in technical problems and safety hazards. This study examines a new passive islanding detection method for photovoltaic‐based distributed generation (DG) units. The modal signal of the three‐phase current and its envelope are calculated for a targeted DG unit. Variance in the autocorrelation of the modal current envelope (VAMCE) is used as an islanding detection criterion in the proposed method. The proposed method employs autocorrelation function (ACF) of modal current envelope (derived by Hilbert‐transform‐based approach) to extract the transient content. Then, the variance of the ACF is calculated, called criterion VAMCE to distinguish between islanded and normal operating conditions. The main advantage of the proposed technique is more relevant to its more accuracy and smaller non‐detection zone in comparison with the other similar passive techniques. Since the VAMCE has significant variation during islanding conditions and negligible change in normal conditions, it can be used for detection of islanding condition effectively. The method was evaluated through several simulations under different islanded and normal operating conditions. The results confirm that the proposed method has better accuracy and speed compared to other similar methods.

21 April 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SKSaad Ullah Khan
Saad Ullah Khan
KMKhawaja Khalid Mehmood
Khawaja Khalid Mehmood
ZHZUNAIB MAQSOOD HAIDER
ZUNAIB MAQSOOD HAIDER
SBSyed Basit Ali Bukhari
Syed Basit Ali Bukhari
SLSoon-Jeong Lee
Soon-Jeong Lee
CKChul-Hwan Kim
Chul-Hwan Kim
The increasing penetration of electric vehicles (EVs) in the distribution grid has established them as a prospective resource for ancillary services. These services require adequate control strategies for prompt and efficient operation. In this study, an energy management scheme (EMS) has been proposed to employ an off-board EV smart charger to support the grid during short-term variance of renewables and reactive load onset. The scheme operates by calculating power references for the charger instantaneously. The EMS incorporates a proportional power division methodology, proposed to allocate power references to the individual EVs connected to the charger DC-bus. This methodology considers the state-of-charge and battery sizes of the EVs, and it can aggregate energy from various types of EVs. The proposed scheme is compared with another power allocation method, and the entire EMS is tested under the scenarios of power mismatch and voltage sag/swell events. The results show that the proposed scheme achieves the goal of the aggregation of EVs at the charger level to support the grid. The EMS also fulfills the objectives of voltage regulation and four-quadrant operation of the smart charger.