Muthanna Adil Abbu

Dr. Muthanna Adil Abbu


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2014 in Steel and Composite Structures
Verified
Journal Article
Closed access
MAMuthanna Adil Abbu
Muthanna Adil Abbu
TETalha A. Ekmekyapar
Talha A. Ekmekyapar
MÖMustafa Özakça
Mustafa Özakça

1 February 2016 in Proceedings of the Institution of Civil Engineers - Structures and Buildings
Verified
Journal Article
Closed access
MAMuthanna Adil Abbu
Muthanna Adil Abbu
TETalha Ekmekyapar
Talha Ekmekyapar
MÖMustafa Özakça
Mustafa Özakça
MFMuthanna Abbu, PhDxMuthanna AbbuSearch for articles by this authorDepartment of Civil Engineering, University of Gaziantep, Gaziantep, Turkey; Department of Civil Engineering, Technical College, Mosul, Iraq Talha Ekmekyapar, PhDxTalha EkmekyaparSearch for
Muthanna Abbu, PhDxMuthanna AbbuSearch for articles by this authorDepartment of Civil Engineering, University of Gaziantep, Gaziantep, Turkey; Department of Civil Engineering, Technical College, Mosul, Iraq Talha Ekmekyapar, PhDxTalha EkmekyaparSearch for
LLLing-Zhi Li
Ling-Zhi Li
BEB. Engström
B. Engström
A three-dimensional (3D) finite-element (FE) model with multiple elements was used to simulate a shear connector with static loading. The behaviour of the steel-in-concrete connection was critical to the global behaviour of the structural element. The geometry and material non-linearities of the studded steel beam shear connector were included in the finite-element model. Contact regions between the concrete and steel elements were simulated using surface-to-surface and embedment techniques. The resulting shear capacity for the studs was compared with several codes of practice. The data for a load–slip curve of shear connectors in composite structures were limited to data obtained from the experimental push-out tests. The model was used to estimate the load–slip curve and to analyse the mechanical behaviour of the connectors – such as the stress distribution – which is usually difficult to evaluate through testing. It was demonstrated that, after careful calibration against test data, the finite-element model was able to predict accurate results for the slip. The reliability of the model was checked against the test results, and it was found that the numerical results for the load–slip curve were in good agreement with the test results.

3 September 2025 in Archives of Civil Engineering
Verified
Journal Article
Open access
PDF file
Jasim Mohammed ABEDJasim Mohammed ABED
Jasim Mohammed ABED
HAHiba Abdulhafith Abdulkareem
Hiba Abdulhafith Abdulkareem
MAMuthanna Adil Abbu
Muthanna Adil Abbu
The rapid expansion of the construction industry worldwide has led to a significant increase in resource use, hence depleting the existing reserves. Utilizing recycled aggregates might potentially reduce the use of natural raw materials in the production of concrete and mortar. This would further aid in reducing the quantity of waste thrown into the environment due to demolition procedures. This study investigated the feasibility of recycling recycled fine aggregate from construction and demolition waste. Limestone powder was utilized as a filler, together with waste from three different kinds of construction and demolition waste (concrete, clay bricks, and ceramics). Cement mortar mixtures of 1:3:0.5 and 1:4:0.5 were used to design 32 different mortar mixes (cement: fine aggregate: filler). Except for the control mixes, the following replacement ratios were tested: 0%, 20%, 40%, 60%, 80%, and 100% for construction and demolition waste as a partial replacement for natural fine aggregate. Cubes, prisms, and cylinders were all used to measure the physical and mechanical properties of the mortar. In this study, the physical properties (workability, dry density) were analyzed. In addition to investigating the mechanical properties (compressive, flexural, and splitting strength), The experimental results showed that the optimal percentage of natural fine aggregate replacing recycled aggregate from construction and demolition waste was 20%. Additionally, the research demonstrated that, due to its cementitious properties, recycled fine aggregate from concrete waste significantly outperformed the reference mixes in terms of all physical and mechanical properties.

28 February 2023 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
MAMuthanna Adil Abbu
Muthanna Adil Abbu
DHDoaa Talib Hashim
Doaa Talib Hashim
HAHasan M. A. Albegmprli
Hasan M. A. Albegmprli
MMMustafa Ridha Mezaal
Mustafa Ridha Mezaal
In this investigation, a kenaf/PLA composite specimen was subjected to the fatigue load, and the results were analyzed numerically. Some of the most significant fatigue tool aspects that were looked into were life expectancy, damage, alternative stress, and biaxiality indication. The static structural tool was utilized in order to predict the numerical analysis, and the calculations were performed with the GoodMan theory of fatigue. The loading was completely reversed so that it was equal to 30 kN. When it was discovered that the system could continue to function even after 1e6 cycles had been completed. After applying the alternative load of 30 kN, the biaxiality indication was found to be 0.425, with a minimum value of 0.9. It has been determined how much damage has occurred. The minimum amount of cycles necessary to reach the maximum damage potential is 1000, while the maximum amount of cycles necessary to reach the maximum damage potential is 1.7662·106. It has been established that there is another stress that is comparable to this one. Based on the findings of the investigation, it was determined that the fillet regions of the specimen were subjected to a maximum alternative stress of 716.4 MPa. The alternative stress cannot drop below 31.276 MPa under any circumstances. It has been determined that 106cycles have been spent living in total by the calculation. It has been found out that there is not going to be any damage regardless of the number of cycles that pass due to the fact that that number is 1. It was found that the alternative stress could reach a maximum value of 716.4 MPa, so that was the value that was used for the alternative stress

1 May 2026
Verified
Book Chapter
Closed access
MAMuthanna Adil Abbu
Muthanna Adil Abbu
SSSaleh J. Suleiman
Saleh J. Suleiman
HNHamid Salim Nasir
Hamid Salim Nasir