Lariza dos Santos Azevedo

Dr. Lariza dos Santos Azevedo


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 September 2018 in Water Science & Technology
Verified
Journal Article
Closed access
LALariza dos Santos Azevedo
Lariza dos Santos Azevedo
ICI. M. P. Castro
I. M. P. Castro
CLC. D. Leal
C. D. Leal
JAJ. C. Araújo
J. C. Araújo
CCC. A. L. Chernicharo
C. A. L. Chernicharo
Two bioreactors were investigated as an alternative to post-treatment of effluent from an upflow anaerobic sludge blanket (UASB) reactor treating domestic sewage, with an aim of oxidizing sulfide into elemental sulfur, and removal of solid and organic material. The bioreactors were operated at different hydraulic retention times (HRTs) (6, 4, and 2 h) and in the presence or absence (control) of packing material (polypropylene rings). Greater sulfide removal efficiencies - 75% (control reactor) and 92% (packed reactor) - were achieved in both reactors for an HRT of 6 h. Higher organic matter (COD) and solid (TSS) removal levels were observed in the packed reactor, which produced effluent with low COD (100 mg CODL-1) and TSS concentrations (30 mg TSSL-1). Denaturing gradient gel electrophoresis results revealed that a metabolically diverse bacterial community was present in both bioreactors, with sequences related to heterotrophic bacteria, sulfur bacteria (Thiocapsa, Sulfurimonas sp., Chlorobaculum sp., Chromatiales and Sulfuricellales), phototrophic purple nonsulfur bacteria (Rhodopseudomonas, Rhodocyclus sp.) and cyanobacteria. The packed reactor presented higher extracellular sulfur formation and potential for elemental sulfur recovery was seen. Higher efficiencies related to the packed reactor were attributed to the presence of packing material and higher cell retention time. The studied bioreactors seemed to be a simple and low-cost alternative for the post-treatment of anaerobic effluent.

1 August 2021 in Engenharia Sanitaria e Ambiental
Verified
Journal Article
Open access
CCCarlos Augusto de Lemos Chernicharo
Carlos Augusto de Lemos Chernicharo
JAJuliana Calabria de Araujo
Juliana Calabria de Araujo
CFCésar Rossas Mota Filho
César Rossas Mota Filho
TBThiago Bressani-Ribeiro
Thiago Bressani-Ribeiro
LCLucas Chamhum-Silva
Lucas Chamhum-Silva
SASérgio Ayrimoraes
Sérgio Ayrimoraes
RESUMO A recente detecção de material genético (RNA) do novo coronavírus em amostras de fezes e no esgoto aponta para a possibilidade de se identificar a circulação do vírus e até mesmo estimar o número de pessoas infectadas em determinada região pelo monitoramento sistemático do esgoto, configurando-se em importante ferramenta epidemiológica de testagem massiva indireta, incluindo portadores sintomáticos e assintomáticos. Nesse sentido, concebeu-se um projeto para a detecção e a quantificação do novo coronavírus em amostras de esgoto coletadas em 15 sub-bacias de esgotamento sanitário dos ribeirões Arrudas e Onça, visando entender a dinâmica de circulação e a prevalência do vírus nas regiões investigadas. Tais sub-bacias esgotam os efluentes gerados por uma população da ordem de 1,5 milhão de pessoas no município de Belo Horizonte e parte de Contagem. O plano de amostragem contemplou 17 pontos (15 sub-bacias + afluente às 2 estações de tratamento de esgoto) de monitoramento semanal, com coletas compostas durante todo o período da manhã. A detecção e a quantificação do RNA viral efetuaram-se em laboratório por meio de ensaios de RT-qPCR. Os resultados obtidos em quatro semanas de monitoramento (semanas epidemiológicas 21 a 24) mostraram um incremento da ocorrência do vírus, atingindo 100% das regiões investigadas na semana epidemiológica 24. A estimativa da população infectada pelo novo coronavírus pelo monitoramento do esgoto em Belo Horizonte apresentou tendência de crescimento exponencial, sendo até 20 vezes maior do que o número de casos confirmados acumulados. Quanto à circulação do vírus, as concentrações do RNA viral têm se mostrado bastante variáveis nas regiões monitoradas, com maiores porcentagens de população infectada estimada ao norte e nordeste da capital mineira.

1 January 2021 in Environmental Technology Reviews
Verified
Journal Article
Closed access
LALariza dos Santos Azevedo
Lariza dos Santos Azevedo
TBThiago Bressani-Ribeiro
Thiago Bressani-Ribeiro
CCC. A. L. Chernicharo
C. A. L. Chernicharo
JAJuliana Calabria de Araujo
Juliana Calabria de Araujo
The anaerobic technology via UASB reactors is consolidated for mainstream sewage treatment in warm climate regions (i.e. Brazil and India). The need to improve the post-treatment step in terms of nitrogen removal has driven researchers and practitioners to assess different technological alternatives. Although the anammox (anaerobic ammonium oxidation) process has been already used in full-scale applications to remove nitrogen from ammonium-rich (> 1000 mgN L−1) wastewaters (sidestream), it is still a concern for mainstream application. Several studies have been performed aiming to solve existing drawbacks related to the implementation of mainstream partial nitritation-anammox (PN/A) for N removal from sewage, however, none of them addressed the particular conditions of anaerobically treated sewage under warm climate conditions. Therefore, this paper presents a critical review of the main limiting factors commonly reported for mainstream PN/A application, focusing on possible applications of single-stage partial nitritation-anammox for post-treatment of anaerobically treated sewage under warm climate conditions. Commonly reported constraints for achieving mainstream PN/A application such as temperature, COD/N ratio, sulfide toxicity and nitrite requirements were addressed. It was concluded that temperature and COD/N should not be concerns for mainstream anammox systems fed on anaerobically treated sewage under warm climate regions. Despite long-term exposure assessments should be still performed, sulfide toxicity seems to be of less relevance. Therefore, reaching reliable nitritation is the major challenge that remains among the typically reported limitations for mainstream PN/A application following anaerobic sewage treatment. GRAPHICAL ABSTRACT

10 September 2021 in Environmental Technology
Verified
Journal Article
Closed access
ICI. M. P. Castro
I. M. P. Castro
LALariza dos Santos Azevedo
Lariza dos Santos Azevedo
CSC. L. Souza
C. L. Souza
This study aimed at evaluating the microaeration as an alternative for hydrogen sulfide removal from biogas of UASB reactors treating sewage. The set-up consisted of two pilot-scale UASB reactors, including a conventional anaerobic and a modified UASB reactor, operated under microaerated conditions. Air was supplied in the digestion zone, at 1 and 3 m from the bottom of the reactor, and three different air flows were investigated: 10, 20, and 30 mL.min-1, corresponding to 0.003, 0.005 and 0.005 LO2/Linfluent, respectively. The main results showed that the microaeration provided a substantial decrease in hydrogen sulfide concentrations when compared to the concentrations observed in the biogas of the anaerobic UASB reactor. Hydrogen sulfide concentrations remained below 70 ppmv throughout the experimental period, corresponding to an average removal efficiency of 98%. Although a decrease in methane concentrations in biogas was observed, the feasibility of energy use would not be affected. The effect of microaeration on the overall performance of the reactor was evaluated, however, no significant differences were observed. The feasibility of limiting aeration conditions in the reactor digestion zone as an efficient alternative for hydrogen sulfide removal from biogas was demonstrated. GRAPHICAL ABSTRACT

21 May 2021 in Water
Verified
Journal Article
Open access
PDF file
PNPriscilla Neves
Priscilla Neves
LALariza dos Santos Azevedo
Lariza dos Santos Azevedo
MHMartijn Hoep
Martijn Hoep
TBThiago Bressani-Ribeiro
Thiago Bressani-Ribeiro
MWMatthijs Wiersma
Matthijs Wiersma
Luewton AgostinhoLuewton Agostinho
Luewton Agostinho
The lack of proper sludge withdrawal routines has been one of the main causes of solids washout and consequent deterioration of effluent quality from up-flow anaerobic sludge blanket (UASB) reactors treating sewage in developing countries. The establishment of an adequate sludge withdrawal routine depends on the knowledge of the sludge mass inside the reactor, but for this, it is necessary to continuously monitor the solid’s profile along the height of the digestion compartment of such reactors. Knowing the sludge concentration at the highest point of this compartment, immediately before the passage of the liquid to the settling compartment, allows the definition of more robust strategies for sludge discharge, in order to not exceed the retention capacity (storage) of solids in the reactor. To couple with that, a low-cost ultrasound sensor was developed and tested with the aim of monitoring total solids concentration inside UASB reactors. Bench and demo-scale tests were performed to validate the developed technology. Results have shown that the sensor can provide real-time values of total solids inside the reactor with 0.1% accuracy up to 1% total solids content.