Oleksandr Soldatkin

Dr. Oleksandr Soldatkin


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2012 in Bioelectrochemistry
Verified
Journal Article
Closed access
OSOleksandr Soldatkin
Oleksandr Soldatkin
IKI.S. Kucherenko
I.S. Kucherenko
VPViktoriya Pyeshkova
Viktoriya Pyeshkova
AKA.L. Kukla
A.L. Kukla
NJN. Jaffrezic-Renault
N. Jaffrezic-Renault
ASA.P. Soldatkin
A.P. Soldatkin

1 October 2013 in Talanta
Verified
Journal Article
Closed access
OSOleksandr Soldatkin
Oleksandr Soldatkin
VPV.M. Peshkova
V.M. Peshkova
OSO.Y. Saiapina
O.Y. Saiapina
IKI.S. Kucherenko
I.S. Kucherenko
ODO.Y. Dudchenko
O.Y. Dudchenko
SDSergei Dzyadevych
Sergei Dzyadevych

7 April 2017 in Discover Nano
Verified
Journal Article
Open access
PDF file
OSO. V. Soldatkina
O. V. Soldatkina
OSOleksandr Soldatkin
Oleksandr Soldatkin
BKB. Ozansoy Kasap
B. Ozansoy Kasap
DKD. Yu. Kucherenko
D. Yu. Kucherenko
IKI. S. Kucherenko
I. S. Kucherenko
SDSergei Dzyadevych
Sergei Dzyadevych
In this work, we developed a new amperometric biosensor for glutamate detection using a typical method of glutamate oxidase (GlOx) immobilization via adsorption on silicalite particles. The disc platinum electrode (d = 0.4 mm) was used as the amperometric sensor. The procedure of biosensor preparation was optimized. The main parameters of modifying amperometric transducers with a silicalite layer were determined along with the procedure of GlOx adsorption on this layer. The biosensors based on GlOx adsorbed on silicalite demonstrated high sensitivity to glutamate. The linear range of detection was from 2.5 to 450 μM, and the limit of glutamate detection was 1 μM. It was shown that the proposed biosensors were characterized by good response reproducibility during hours of continuous work and operational stability for several days. The developed biosensors could be applied for determination of glutamate in real samples.

25 February 2016 in Discover Nano
Verified
Journal Article
Open access
PDF file
TVT. P. Velychko
T. P. Velychko
OSOleksandr Soldatkin
Oleksandr Soldatkin
VMV. G. Melnyk
V. G. Melnyk
SMSvitlana Marchenko
Svitlana Marchenko
SKS. K. Kirdeciler
S. K. Kirdeciler
SDSergei Dzyadevych
Sergei Dzyadevych
Development of a conductometric biosensor for the urea detection has been reported. It was created using a non-typical method of the recombinant urease immobilization via adsorption on nanoporous particles of silicalite. It should be noted that this biosensor has a number of advantages, such as simple and fast performance, the absence of toxic compounds during biosensor preparation, and high reproducibility (RSD = 5.1 %). The linear range of urea determination by using the biosensor was 0.05–15 mM, and a lower limit of urea detection was 20 μM. The bioselective element was found to be stable for 19 days. The characteristics of recombinant urease-based biomembranes, such as dependence of responses on the protein and ion concentrations, were investigated. It is shown that the developed biosensor can be successfully used for the urea analysis during renal dialysis.

2 March 2017 in Discover Nano
Verified
Journal Article
Open access
PDF file
BKBerna Ozansoy Kasap
Berna Ozansoy Kasap
SMSvitlana Marchenko
Svitlana Marchenko
OSOleksandr Soldatkin
Oleksandr Soldatkin
SDSergei Dzyadevych
Sergei Dzyadevych
BABurcu Akata
Burcu Akata
The combination of advantages of using zeolites and gold nanoparticles were aimed to be used for the first time to improve the characteristic properties of ion selective field-effect transistor (ISFET)-based creatinine biosensors. The biosensors with covalently cross-linked creatinine deiminase using glutaraldehyde (GA) were used as a control group, and the effect of different types of zeolites on biosensor responses was investigated in detail by using silicalite, zeolite beta (BEA), nano-sized zeolite beta (Nano BEA) and zeolite BEA including gold nanoparticle (BEA-Gold). The presence of gold nanoparticles was investigated by ICP, STEM-EDX and XPS analysis. The chosen zeolite types allowed investigating the effect of aluminium in the zeolite framework, particle size and the presence of gold nanoparticles in the zeolitic framework. After the synthesis of different types of zeolites in powder form, bare biosensor surfaces were modified by drop-coating of zeolites and creatinine deiminase (CD) was adsorbed on this layer. The sensitivities of the obtained biosensors to 1 mM creatinine decreased in the order of BEA-Gold > BEA > Nano BEA > Silicalite > GA. The highest sensitivity belongs to BEA-Gold, having threefold increase compared to GA, which can be attributed to the presence of gold nanoparticle causing favourable microenvironment for CD to avoid denaturation as well as increased surface area. BEA zeolites, having aluminium in their framework, regardless of particle size, gave higher responses than silicalite, which has no aluminium in its structure. These results suggest that ISFET biosensor responses to creatinine can be tailored and enhanced upon carefully controlled alteration of zeolite parameters used to modify electrode surfaces.

1 April 2015 in Talanta
Verified
Journal Article
Closed access
OSOleksandr Soldatkin
Oleksandr Soldatkin
ANA. Nazarova
A. Nazarova
NKN. Krisanova
N. Krisanova
ABA. Borуsov
A. Borуsov
DKD. Kucherenko
D. Kucherenko
TBT. Borisova
T. Borisova