Development of a conductometric biosensor for the urea detection has been reported. It was created using a non-typical method of the recombinant urease immobilization via adsorption on nanoporous particles of silicalite. It should be noted that this biosensor has a number of advantages, such as simple and fast performance, the absence of toxic compounds during biosensor preparation, and high reproducibility (RSD = 5.1 %). The linear range of urea determination by using the biosensor was 0.05–15 mM, and a lower limit of urea detection was 20 μM. The bioselective element was found to be stable for 19 days. The characteristics of recombinant urease-based biomembranes, such as dependence of responses on the protein and ion concentrations, were investigated. It is shown that the developed biosensor can be successfully used for the urea analysis during renal dialysis.
The combination of advantages of using zeolites and gold nanoparticles were aimed to be used for the first time to improve the characteristic properties of ion selective field-effect transistor (ISFET)-based creatinine biosensors. The biosensors with covalently cross-linked creatinine deiminase using glutaraldehyde (GA) were used as a control group, and the effect of different types of zeolites on biosensor responses was investigated in detail by using silicalite, zeolite beta (BEA), nano-sized zeolite beta (Nano BEA) and zeolite BEA including gold nanoparticle (BEA-Gold). The presence of gold nanoparticles was investigated by ICP, STEM-EDX and XPS analysis. The chosen zeolite types allowed investigating the effect of aluminium in the zeolite framework, particle size and the presence of gold nanoparticles in the zeolitic framework. After the synthesis of different types of zeolites in powder form, bare biosensor surfaces were modified by drop-coating of zeolites and creatinine deiminase (CD) was adsorbed on this layer. The sensitivities of the obtained biosensors to 1 mM creatinine decreased in the order of BEA-Gold > BEA > Nano BEA > Silicalite > GA. The highest sensitivity belongs to BEA-Gold, having threefold increase compared to GA, which can be attributed to the presence of gold nanoparticle causing favourable microenvironment for CD to avoid denaturation as well as increased surface area. BEA zeolites, having aluminium in their framework, regardless of particle size, gave higher responses than silicalite, which has no aluminium in its structure. These results suggest that ISFET biosensor responses to creatinine can be tailored and enhanced upon carefully controlled alteration of zeolite parameters used to modify electrode surfaces.
In the work, silicalite particles were used for the surface modification of pH-sensitive field-effect transistors (pH-FETs) with the purpose of developing new creatinine-sensitive biosensor. Creatinine deiminase (CD) adsorbed on the surface of silicalite-coated pH-FET served as a bioselective membrane. The biosensor based on CD immobilized in glutaraldehyde vapor (GA) was taken as control. The creatinine-sensitive biosensor obtained by adsorption on silicalite was shown to have better analytical characteristics (two- to threefold increased sensitivity to creatinine, three- to fourfold lesser response and recovery times, a decrease of the detection limit of creatinine determination to 5 μM, etc.). Additionally, the biosensor based on CD adsorbed on silicalite (Sil/CD) was characterized by high signal reproducibility (relative standard deviation (RSD) for creatinine measurement = 2.6 %) and stability during storage (over 13 months). It was experimentally confirmed that the proposed biosensor was not sensitive either to high concentrations of sodium chloride or to the macromolecular protein fractions and can be used for direct quantitative analysis of creatinine in the blood serum. It was concluded that the method of CD adsorption on silicalite is well-suited for the creation of creatinine-sensitive biosensor with improved working characteristics.
In the work, the method was proposed to improve the analytical characteristics of the potentiometric urease-based biosensor for urea determination. The method consisted in the addition of cyclodextrins to the bioselective membrane. The results obtained when adding cyclodextrins of different types were compared; the biosensor with β-HP-cyclodextrin turned out to exhibit the best characteristics. It was established that the latter has the sensitivity to urea at least by 50% higher than the biosensor with no cyclodextrin. Additionally, the developed biosensor with β-HP-cyclodextrin was characterized by good signal reproducibility with a small error (RSD = 2.65%) and high operational stability for 15 days. The results of this work are promising for further use of the developed biosensor in clinical diagnostics.
14 October 2012 in Sensor Electronics and Microsystem Technologies
В роботі показано застосування високочутливого та селективного біосенсора на основі рН-чутливого польового транзистора та іммобілізованої рекомбінантної уреази з модифікованим активним центром для визначення концентрацій сечовини. Оптимізовано основні аналітичні характеристики розробленого біосенсора та визначено оптимальні умови проведення досліджень з реальними зразками. Проведено кількісне визначення вмісту сечовини в сироватці крові та діалізаті і проведено порівняльний аналіз даних біосенсорного визначення з контрольними загальноприйнятими методами (показано високу кореляцію).