Phase compensated proportional resonant (PR) controllers with phase leading angles embedded into resonant controllers, are used to improve the system stability, when the grid-connected inverter is connected to a weak grid with large grid impedance. However, an inappropriate phase leading angle will cause obvious anti-peak in the magnitude response of phase compensated PR controller. Thus, the phase leading angle should be selected carefully. The conventional phase compensation (CPC) method for selecting the phase leading angle can maximize the system phase margin, but at the expense of large peaks in the magnitude response of sensitivity transfer function. Meanwhile, the bandwidths of resonant controllers will be reduced. In the paper, an improved phase compensation (IPC) method is proposed, which does not cause peaks in the magnitude response of sensitivity transfer function while providing sufficient phase margin. Experimental tests were carried out on a single phase grid-connected inverter. The effectiveness of the proposed method is proved in terms of the steady-state and transient performances, as well as the performance under the grid frequency deviation.
31 March 2021 in IEEE Transactions on Industry Applications
The capability of dynamic grid support of a voltage source converter-high voltage direct current (VSC-HVdc) system depends on the maximum allowable current of the converter. This study attempts to increase the capability by overloading the power semiconductor device for a short period of time. Keeping the device temperature low is a major challenge due to the extra loss and small local thermal capacity. This study investigates a solution to increase the transient thermal capacity by making use of the latent heat of a phase change material (PCM). This article presents an integration scheme for a press pack power module, focusing on the fast recovery diode in an IGBT-diode package. Experiment and finite element analysis are used to evaluate the concept and analyze the factors affecting the design. It is shown that as heat is absorbed by the integrated PCM, the device temperature rise during a power surge is effectively tempered, providing a high short-term overcurrent rating of the device and an increased dynamic grid support capability of the VSC-HVdc system.
26 October 2021 in IEEE Transactions on Sustainable Energy
Long-distance power transmission makes a large-scale centralized photovoltaic (PV) power plant (CPPP) integrated into a weak power grid with a low short circuit ratio. Under this condition, small fluctuations in PV power are likely to cause significant fluctuations in system-wide voltage. To overcome this problem, a novel CPPP Volt-Var control (VVC) strategy is proposed. Unlike the conventional VVC strategy achieved in a centralized manner, the realization of the proposed VVC is mainly based on decentralized communication. The control framework for the proposed VVC has two tiers. In the upper-tier “optimal control”, a distributed VVC optimization model is formulated. Analysis target cascading (ATC) and alternating direction method of multipliers (ADMM) are combined to provide 15-minute-ahead optimal VVC scheduling, considering voltage deviation and active power losses together. In the lower tier “emergency control”, local droop control is applied to respond to the unexpected voltage deviation in real time. The final simulation results indicate that the proposed VVC strategy has good performances on the algorithm convergence in the upper tier and the control stability in the lower tier. The entire two-stage VVC could effectively maintain the system-wide voltage within the safe range and perform well on active power losses reduction, without the central controller.