26 October 2021 in IEEE Transactions on Sustainable Energy
Long-distance power transmission makes a large-scale centralized photovoltaic (PV) power plant (CPPP) integrated into a weak power grid with a low short circuit ratio. Under this condition, small fluctuations in PV power are likely to cause significant fluctuations in system-wide voltage. To overcome this problem, a novel CPPP Volt-Var control (VVC) strategy is proposed. Unlike the conventional VVC strategy achieved in a centralized manner, the realization of the proposed VVC is mainly based on decentralized communication. The control framework for the proposed VVC has two tiers. In the upper-tier “optimal control”, a distributed VVC optimization model is formulated. Analysis target cascading (ATC) and alternating direction method of multipliers (ADMM) are combined to provide 15-minute-ahead optimal VVC scheduling, considering voltage deviation and active power losses together. In the lower tier “emergency control”, local droop control is applied to respond to the unexpected voltage deviation in real time. The final simulation results indicate that the proposed VVC strategy has good performances on the algorithm convergence in the upper tier and the control stability in the lower tier. The entire two-stage VVC could effectively maintain the system-wide voltage within the safe range and perform well on active power losses reduction, without the central controller.
22 August 2023 in IEEE Transactions on Industry Applications
The distribution network (DN) reconfiguration is a well-known optimal power flow (OPF) problem. However, with the transition of DN from “passive” to “active”, new technical challenges arise in DN reconfiguration. This paper addresses two key issues in this regard. Firstly, the integration of local renewable generation (LRG) introduces uncertainty into the system-wide power flow of the DN. Secondly, the coupling between DN and the external power grid (EPG) affects the determination of DN root voltage. Consequently, a novel DN reconfiguration approach is proposed in this paper. To begin with, an explicit mixed-integer convex OPF model is constructed that incorporates both the EPG and DN sides. Notably, the OPF model embeds the function of local droop control that is provided by LRG. Subsequently, the original OPF model is decomposed, and the distributed optimization methods based on the augmented Lagrangian relaxation are employed. The paper comprehensively discusses parallel processing and asynchronous implementation as parts of the distributed optimization procedure. Furthermore, to address the uncertainty related to LRG integration, the extreme scenario method is used to provide a robust decision regarding DN reconfiguration. The application of the extreme scenario method in the distributed OPF model concerning DN reconfiguration is successively developed. Finally, numerical results are presented to demonstrate the acceptable performance of the distributed optimization methods, in terms of optimality and convergence. Also, these are validated that the proposed DN reconfiguration approach exhibits robustness to LRG integration, the system-wide voltage profile is improved, and the active power loss is effectively reduced using the proposed DN reconfiguration approach.
22 September 2023 in IEEE Sensors Journal
In wireless power transfer (WPT) systems for electric vehicles, the detection of the secondary-side coil plays a crucial role in determining whether the vehicle is within the effective charging area. However, most existing detection approaches based on sensors require modifying the vehicle structure, which has several flaws such as limited adaptability to different vehicles, compromised preservation of the original magnetic coupler’s structure, and potential magnetic interferences with the primary-side coil operation. Driven by the mentioned issues, we propose a novel detection approach based on triple-U auxiliary coil with an equilateral triangle structure. This design preserves the integrity of the secondary-side coil and offers flexibility in accommodating different positioning heights. Besides, the triple-U auxiliary coil effectively mitigates interferes with the operation of the primary-side coil due to the reason that magnetic coupling between these two coils is eliminated. Further, a tailored positioning and direction-guided approach are proposed. This approach is capable of reaching the high-precision detection of the secondary-side coil. Meanwhile, it manages to guide the secondary-side coil to the desired area, approaching perfect alignment with the primary-side coil. Finally, A WPT system prototype incorporating the triple-U auxiliary coil is constructed to validate our proposed detection approach. Experiment results indicate that the maximum recognition range reaches 300mm×400mm and 400mm×300mm, when the secondary-side coil is the rectangular and double-D coil, respectively. Moreover, in both situations, the maximum positioning height achieves 250mm and the positioning resolution is refined to 10mm.