Haixiao Li

Haixiao Li

Auto-generated profile, based on publicly available information

Haixiao Li

School of Electrical and Electronic Engineering, Chongqing University of Technology, Chongqing 400054, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2021 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
HLHaixiao Li
Haixiao Li
KGKe Guo
Ke Guo
GHGaofeng Hao
Gaofeng Hao
MMMingxuan Mao
Mingxuan Mao
LZLin Zhou
Lin Zhou
Long-distance power transmission makes a large-scale centralized photovoltaic (PV) power plant (CPPP) integrated into a weak power grid with a low short circuit ratio. Under this condition, small fluctuations in PV power are likely to cause significant fluctuations in system-wide voltage. To overcome this problem, a novel CPPP Volt-Var control (VVC) strategy is proposed. Unlike the conventional VVC strategy achieved in a centralized manner, the realization of the proposed VVC is mainly based on decentralized communication. The control framework for the proposed VVC has two tiers. In the upper-tier “optimal control”, a distributed VVC optimization model is formulated. Analysis target cascading (ATC) and alternating direction method of multipliers (ADMM) are combined to provide 15-minute-ahead optimal VVC scheduling, considering voltage deviation and active power losses together. In the lower tier “emergency control”, local droop control is applied to respond to the unexpected voltage deviation in real time. The final simulation results indicate that the proposed VVC strategy has good performances on the algorithm convergence in the upper tier and the control stability in the lower tier. The entire two-stage VVC could effectively maintain the system-wide voltage within the safe range and perform well on active power losses reduction, without the central controller.

22 August 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
HLHaixiao Li
Haixiao Li
ALAleksandra Lekić
Aleksandra Lekić
SLShan Li
Shan Li
DJDongrong Jiang
Dongrong Jiang
QGQiang Guo
Qiang Guo
LZLin Zhou
Lin Zhou
The distribution network (DN) reconfiguration is a well-known optimal power flow (OPF) problem. However, with the transition of DN from “passive” to “active”, new technical challenges arise in DN reconfiguration. This paper addresses two key issues in this regard. Firstly, the integration of local renewable generation (LRG) introduces uncertainty into the system-wide power flow of the DN. Secondly, the coupling between DN and the external power grid (EPG) affects the determination of DN root voltage. Consequently, a novel DN reconfiguration approach is proposed in this paper. To begin with, an explicit mixed-integer convex OPF model is constructed that incorporates both the EPG and DN sides. Notably, the OPF model embeds the function of local droop control that is provided by LRG. Subsequently, the original OPF model is decomposed, and the distributed optimization methods based on the augmented Lagrangian relaxation are employed. The paper comprehensively discusses parallel processing and asynchronous implementation as parts of the distributed optimization procedure. Furthermore, to address the uncertainty related to LRG integration, the extreme scenario method is used to provide a robust decision regarding DN reconfiguration. The application of the extreme scenario method in the distributed OPF model concerning DN reconfiguration is successively developed. Finally, numerical results are presented to demonstrate the acceptable performance of the distributed optimization methods, in terms of optimality and convergence. Also, these are validated that the proposed DN reconfiguration approach exhibits robustness to LRG integration, the system-wide voltage profile is improved, and the active power loss is effectively reduced using the proposed DN reconfiguration approach.

18 July 2023 in Electronics
Verified
Journal Article
Open access
PDF file
CLChunyan Li
Chunyan Li
Yi YangYi Yang
Yi Yang
WLWenyan Li
Wenyan Li
HLHaixiao Li
Haixiao Li
The occurrence of high-amplitude magnetizing inrush current during the energization of a transformer without load poses significant challenges to the stable operation of both the transformer and the power grid, potentially leading to malfunctions in relay protection devices. This paper analyzes the underlying mechanisms of transformer inrush current and presents a novel approach utilizing a soft-start-based method for effectively suppressing inrush currents. The proposed method employs an inrush current suppressor comprising anti-parallel thyristors and filters to mitigate the adverse effects caused by the inrush current. A comparative study is conducted to evaluate the filtering efficacy of three types of filters incorporated in the inrush current suppressor: an LCLC damping filter, a high-order single trap filter and a high-order double trap filter. Through careful analysis and optimization, the high-order double trap filter with parallel RC damping damper is selected as the optimal configuration. To ensure effective suppression, it is necessary to incorporate a filter at the termination point of the anti-parallel thyristor. Additionally, a closed-loop control strategy is implemented to ensure a smooth start and actively suppress the magnetizing inrush current. To validate the effectiveness of the proposed method, comprehensive simulations are performed using Matlab/Simulink. The results demonstrate the successful suppression of inrush current and the maintenance of stable operation for the transformer. This inrush suppression method does not require considering the influence of residual magnetism and the grounding mode of the transformer’s neutral point. It is also suitable for various transformer structures and wiring methods, which makes it highly applicable.

22 September 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Yi YangYi Yang
Yi Yang
GCGuimei Cao
Guimei Cao
HLHaixiao Li
Haixiao Li
In wireless power transfer (WPT) systems for electric vehicles, the detection of the secondary-side coil plays a crucial role in determining whether the vehicle is within the effective charging area. However, most existing detection approaches based on sensors require modifying the vehicle structure, which has several flaws such as limited adaptability to different vehicles, compromised preservation of the original magnetic coupler’s structure, and potential magnetic interferences with the primary-side coil operation. Driven by the mentioned issues, we propose a novel detection approach based on triple-U auxiliary coil with an equilateral triangle structure. This design preserves the integrity of the secondary-side coil and offers flexibility in accommodating different positioning heights. Besides, the triple-U auxiliary coil effectively mitigates interferes with the operation of the primary-side coil due to the reason that magnetic coupling between these two coils is eliminated. Further, a tailored positioning and direction-guided approach are proposed. This approach is capable of reaching the high-precision detection of the secondary-side coil. Meanwhile, it manages to guide the secondary-side coil to the desired area, approaching perfect alignment with the primary-side coil. Finally, A WPT system prototype incorporating the triple-U auxiliary coil is constructed to validate our proposed detection approach. Experiment results indicate that the maximum recognition range reaches 300mm×400mm and 400mm×300mm, when the secondary-side coil is the rectangular and double-D coil, respectively. Moreover, in both situations, the maximum positioning height achieves 250mm and the positioning resolution is refined to 10mm.

15 December 2021
Verified
Conference Paper
Closed access
HLHaixiao Li
Haixiao Li
SLShan Li
Shan Li
DJDongrong Jiang
Dongrong Jiang
QGQiang Guo
Qiang Guo
LZLin Zhou
Lin Zhou
The integration of distributed generators (DGs) has transformed the traditional distribution network (DN) into a new type of active DN. With the high penetration of DGs, the DN might send power back to the external power grid (EPG), and the coupling between DN and EPG is enhanced. Nevertheless, most of the existing DN reconfiguration strategies ignore the impact of EGP operation on DN, especially the root voltage of DN. For this reason, in the proposed strategy, the impact of EPG is considered, and distributed-manner-based analysis target cascading (ATC) is utilized to coordinate the boundary node information between DN and EPG. Based on the constructed integrated problem of nonlinear programming (NLP) and mixed-integer quadratic programming (MIQP), the optimal DN reconfiguration plan is obtained with minimizing power loss as an optimization objective. The proposed strategy is verified by the test system combining IEEE-9 and IEEE-33. The simulation results indicate that the proposed reconfiguration strategy can fully consider the interactions between EPG and DN and effectively control the system-wide voltage within the allowed range through the suitable approach of network reconfiguration.

Verified
Journal Article
Open access
PDF file
Yi YangYi Yang
Yi Yang
ZLZhihao Lin
Zhihao Lin
HLHaixiao Li
Haixiao Li
KGKe Guo
Ke Guo
JJJianhao Jiang
Jianhao Jiang
To address the issue of significantly reduced coupling coefficient and limited transmission efficiency in traditional flat solenoid magnetic couplers within wireless power transfer (WPT) systems under horizontal lateral offset conditions, this paper proposes a design method for a concave flat solenoid coil magnetic coupler for engineering applications, aiming to achieve high misalignment tolerance. An equivalent model of the LCC/S compensation circuit is established, its output characteristics are analyzed, and the parameter configuration method for its resonant elements is derived. Secondly, from the perspective of winding arrangement, the mechanism by which the coil winding method, turn spacing, and port concavity angle affect the uniformity of magnetic field distribution and the retention rate of the coupling coefficient is analyzed in detail, and corresponding parameter trade-off and optimization methods are proposed. Subsequently, a simulation model of multiple configuration magnetic couplers is established based on Ansys/Maxwell, comparing the magnetic field distribution and coupling coefficient variation of different structures under horizontal offset conditions. The results show that the concave structure with a non-uniform arrangement and a port concavity angle of 30° can still maintain a high coupling coefficient and stable transmission performance under a maximum horizontal offset equal to 60% of the corresponding transmitter-side characteristic dimension. To achieve lightweight and integrated design, the receiver is designed with a flexible printed circuit board (FPC) coil structure, meeting the miniaturization and high power density requirements of low-to-medium power portable devices. Finally, a 100 W experimental prototype was built. Experimental results show that within an offset range of ±15 mm on the X-axis and ±30 mm on the Y-axis at the receiver, the system output voltage fluctuation is controlled within 4%, and the maximum transmission efficiency reaches 87.3%. These results verify the feasibility and practical applicability of the proposed magnetic coupler with high misalignment tolerance.