Orcun Taylan

Mr. Orcun Taylan


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
FDFélix Dandois
Félix Dandois
OTOrcun Taylan
Orcun Taylan
JBJohan Bellemans
Johan Bellemans
JDJan D'hooge
Jan D'hooge
HVHilde Vandenneucker
Hilde Vandenneucker
LSLennart Scheys
Lennart Scheys
Current ultrasound techniques face several challenges to measure strains when translated from large tendon to in-situ knee collateral ligament applications, despite the potential to reduce knee arthroplasty failures attributed to ligament imbalance. Therefore, we developed, optimized and validated an ultrasound speckle tracking method to assess the in-situ strains of the medial and lateral collateral ligaments. Nine cadaveric legs with total knee implants were submitted to varus/valgus loading and divided into two groups: “optimization” and “validation”. Reference strains were measured using digital image correlation technique, while ultrasound data were processed with a custom-built speckle tracking approach. Using specimens from the “optimization” group, several tracking parameters were tuned towards an optimized tracking performance. The parameters were ranked according to three comparative measures between the ultrasound-based and reference strains: R2, mean absolute error and strains differences at 40 N. Specimens from the “validation” group, processed with the optimal parameters, showed good correlations, along with small mean absolute differences, with correlation values above 0.99 and 0.89 and differences below 0.57% and 0.27% for the lateral and medial collateral ligaments, respectively. This study showed that ultrasound speckle tracking could assess knee collateral ligaments strains in situ and has the potential to be translated to clinics for knee arthroplasty-related procedures.

16 February 2022 in Foot and Ankle Surgery
Verified
Journal Article
Closed access
FMFrederick Michels
Frederick Michels
OTOrcun Taylan
Orcun Taylan
FSFilip Stockmans
Filip Stockmans
EVEvie Vereecke
Evie Vereecke
LSLennart Scheys
Lennart Scheys
Giovanni A. MatricaliGiovanni A. Matricali
Giovanni A. Matricali

1 October 2022 in Foot and Ankle Surgery
Verified
Journal Article
Closed access
JRJoris Robberecht
Joris Robberecht
DSDarshan S. Shah
Darshan S. Shah
OTOrcun Taylan
Orcun Taylan
TNTassos Natsakis
Tassos Natsakis
GVGeoffroy Vandeputte
Geoffroy Vandeputte
IJIlse Jonkers
Ilse Jonkers

12 July 2025 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
GOGregory Ophoff
Gregory Ophoff
JBJohan Bellemans
Johan Bellemans
DADaniele Ascani
Daniele Ascani
OTOrcun Taylan
Orcun Taylan
LSLennart Scheys
Lennart Scheys
GPGeert Peersman
Geert Peersman

29 March 2023 in Clinical Biomechanics
Verified
Journal Article
Closed access
OTOrcun Taylan
Orcun Taylan
JSJosh Slane
Josh Slane
NBNathalie van Beek
Nathalie van Beek
FDFélix Dandois
Félix Dandois
LSLennart Scheys
Lennart Scheys
SCSteven Claes
Steven Claes

28 March 2026 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
MDMargot Demeulenaere
Margot Demeulenaere
OTOrcun Taylan
Orcun Taylan
MBMaciej Biały
Maciej Biały
AVArne Van de Vyver
Arne Van de Vyver
TLThomas Louwagie
Thomas Louwagie
LSLennart Scheys
Lennart Scheys
Inroduction This cadaveric study aimed to assess the accuracy of the Next-AR navigation platform in terms of implant alignment, kinematics, and collateral ligament elongations in comparison to gold standard measurement tools. Materials and methods Computed tomography of 7 fresh-frozen legs were acquired for patient-specific guide design, identification of bony landmarks and collateral ligaments to acquire real-time feedback for bone resection, alignment and collateral ligament elongations using Next-AR system. The specimens underwent medially-stabilized TKA (Medacta) based on the mechanical alignment technique. The difference between target and achieved implant alignment parameters was assessed. The relative change in tibiofemoral kinematics, medial collateral ligament- (MCL), and lateral collateral ligament (LCL) elongations acquired with the Next-AR system were compared to reference values acquired with bone-pin mounted motion trackers (Vicon, UK) while performing quasistatic squatting in an ex vivo knee simulator. Results The mean differences between achieved and target hip-knee-ankle angle, femoral varus, femoral flexion, femoral rotation, tibial varus, and tibial slope measured -1.5°, 0.5°, 0.07°, -0.14°, 0.79° and -0.36°, respectively, with no statistically significant differences found (p ≥ 0.12). Knee flexion (p=0.32) and valgus orientation (p=0.63), obtained from Next-AR and Vicon systems were comparable. Collateral ligament elongations derived from Next-AR exhibited similar values for the anterior bundle of MCL (p=0.18) and LCL in the anterior and middle bundles (p>0.3) obtained from the Vicon system. Conclusions Our findings showed that the Next-AR system achieved postoperative implant alignment close to the planned targets, with small systematic deviation (mean bias ≤ 1.5°), limited total error (RMSE ≤ 2.3°), and variability of paired differences ≤ 1.87°, while additionally providing quantitative real-time assessment of tibiofemoral kinematics and collateral ligament elongations.