This paper presents investigations concerning the thermal firebrand reaction due to its accumulation in the top of ceramic roof tiles, commonly applied to the exterior of dwellings in southern Europe. A large-scale fire experiment is conducted, wherein firebrands are placed above the tiles and temperature readings are taken from multiple layers of the building components. The selection of materials for the roof layer assembly was based on recommendations for either fire resistance or high temperature behaviour. The test follows the fire setup recommended in the California Building Code for firebrand deposition. This investigation will allow for a more accurate verification of the firebrand reaction in the roof, including the type of ignition, the creation of smoke and droplets, and even their mechanical ability to withstand elevated temperatures.
3 July 2024 in Periodica Polytechnica Civil Engineering
The use of self-compacting concrete in structural members has become increasingly prevalent in various construction applications. However, these structures are susceptible to one of the most hazardous disasters, which is the fire. This paper presents a numerical investigation of the fire resistance performance of self-compacting reinforced concrete (SCC) beams, as well as a parametric study to assess the impact of hybrid fibres and fire insulation on enhancing their performance under fire conditions. The study is conducted by developing a 3D finite element (FE) model using ANSYS software, where temperatures are applied according to the ISO834 standard fire. Geometric and material nonlinearities are considered in the evaluation of the behaviour of beams under fire conditions. The developed FE model is validated by comparing the predicted results with those of the experimental tests in literature. The fire resistance performance of SCC beams was compared with that of normal strength concrete (NSC) beams. The parametric study is conducted using three types of fire insulation, namely Tyfo WR-AFP, CAFCO 300, and Carboline Type-5MD. The results showed that SCC beam has lower fire resistance performance than the NSC beam. However, the incorporation of hybrid fibres allows a 17% improvement in the fire resistance of SCC beams. The use of fire insulations has increased the fire resistance time of SCC beams, and more particularly Carboline Type-5MD insulation with an increase of 28%. The combined use of hybrid fibres and fire insulation improved the fire resistance of SCC beams by 43%.
This paper presents research concerning simulating the thermal firebrand effect due to its accumulation in exterior construction wall elements by developing a 3D finite element model (FEM) via ABAQUS (2022) software to analyze the exterior walls commonly applied to the exterior of dwellings in southern Europe and South America. A non-linear thermal transient analysis is undertaken, in which the results are directly compared with a previous experimental campaign, in which firebrands are deposited on localized surfaces of construction wall specimens, and the temperature is measured in the several layers of the construction elements. The walls are composite elements, made of different layer combinations of masonry brick and wood, varying the type of thermal insulation in the internal core from cork to classical rigid rockwool and polystyrene foam (XPS). It can be summarized from the results that the FEM effectively simulates the thermal response of brick, normal wood (NW), and cross-laminated timber (CLT) walls when insulated with materials like cork or rockwool coated with mortar against firebrand accumulation. However, the lack of accounting for uncontrolled combustion leads to inconsistent results. Additionally, for walls using XPS as the insulation material, the model requires further refinement to accurately simulate the melting phenomenon and its thermal impact.