Mammalian blood cell separation methods contribute to improving the diagnosis and treatment of animal and human diseases. Microfluidic deterministic lateral displacement (DLD) devices can sort cells based on their particle diameter. We developed microfluidic DLD devices with poly(propylene)-based resin and used them to separate bovine and human red blood cells (RBCs) and white blood cells (WBCs) without electric devices. To determine the critical cut-off diameter (Dc) of these devices, we used immunobeads with a diameter of 1–20 μm. The Dc values of the microfluidic DLD devices for the immunobeads in the experiments were similar to the calculated Dc values (8–10 μm). Results from bovine blood cell separation experiments suggest that lymphocytes and neutrophils can be separated from diluted, whole blood. Human RBCs were occasionally observed in the left outlet where larger particles with diameters closer to the Dc value were collected. Based on the Dc values, human neutrophils were sorted to the left outlet, whereas lymphocytes were observed in both outlets. Although microfluidic channel optimization is required for the concentration of sorted cells, the microfluidic DLD device prepared with a poly(propylene)-based resin has the potential for clinical use.
29 July 2020 in Bioengineering & Translational Medicine
Male infertility affects millions of males worldwide and is rising in prevalence due to social and environmental conditions. However, men often feel too embarrassed to receive a semen analysis in the hospital due to social stigmas. To overcome this problem, we developed a 3‐(4,5‐Dimethyl‐2‐thiazolyl)‐2,5‐diphenyl‐2H‐tetrazolium bromide test strip to distinguish semen samples with low total motile sperm concentration from those with normal motile sperm concentration. This is a point‐of‐care colorimetric semen analytical method with a one‐step, inexpensive, equipment‐free evaluation process, and adequate accuracy validated in a 42‐sample clinical trial. In this study, results were evaluated visually and with a smartphone application. Using visual observation methods, the area under the curve (AUC) was 0.71 (95% of confidence interval = 0.55–0.86; p = 0.021), sensitivity was 41%, specificity was 95%, positive predictive value was 90%, negative predictive value (NPV) was 59.4%, and accuracy was 67%. Using a smartphone recording and analytical system, AUC was 0.766 (95% of confidence interval = 0.612–0.92; p = 0.003), sensitivity was 96%, specificity was 65%, PPV was 75%, NPV was 92.9%, and accuracy was 80.9%. This work demonstrated a screening tool that could elevate semen analysis to the level of routine healthcare and provide for private, in‐home self‐assessment.
Biofilm formation in microfluidic channels is difficult to detect because sampling volumes are too small for conventional turbidity measurements. To detect biofilm formation, we used an ion-sensitive field-effect transistor (ISFET) measurement system to measure pH changes in small volumes of bacterial suspension. Cells of Micrococcus luteus (M. luteus) were cultured in polystyrene (PS) microtubes and polymethylmethacrylate (PMMA)-based microfluidic channels laminated with polyvinylidene chloride. In microtubes, concentrations of bacteria and pH in the suspension were analyzed by measuring turbidity and using an ISFET sensor, respectively. In microfluidic channels containing 20 μL of bacterial suspension, we measured pH changes using the ISFET sensor and monitored biofilm formation using a microscope. We detected acidification and alkalinization phases of M. luteus from the ISFET sensor signals in both microtubes and microfluidic channels. In the alkalinization phase, after 2 day culture, dense biofilm formation was observed at the bottom of the microfluidic channels. In this study, we used an ISFET sensor to detect biofilm formation in clinical and industrial microfluidic environments by detecting alkalinization of the culture medium.
Hydrogen bubble plumes are generated from the cathode during electrolysis. The plume formation mechanism contributes to the control of bubble diameters and alignment in solvent. The generation of hydrogen bubbles (HBs) and oxygen bubbles (OBs) from electrodes was observed in tap water and saline using a high-speed microscope. Bubble diameter changes were analysed from the obtained microscopic images, and the growth kinetics of HBs and OBs were compared. The result showed that plume formation was primarily dependent on ion strength of water and not voltage to the electrode. HB diameter change in plume was proportional to the distance from the cathode in tap water. Such correlation between HB diameter and distance from the cathode was not observed in saline. By simultaneous observation of HBs and OBs attached to the electrodes, the increase in HB diameter was faster than that of OB. The kinetic properties in HBs and OBs were proportional to (time) 1/2 and (time) 1 , respectively, suggesting that the diffusion of oversaturated hydrogen gas and pressure difference at OB surfaces were dominant. Based on these results, HB plume formation was determined by the lower gas solubility and mass density of HB than that of OB, as well as controlled by voltage and ionic strength of water.