Yu-Ting Tsao

Ms. Yu-Ting Tsao

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
YHYi-Jen Hsueh
Yi-Jen Hsueh
YCYen-Ning Chen
Yen-Ning Chen
YTYu-Ting Tsao
Yu-Ting Tsao
Chao-Min ChengChao-Min Cheng
Chao-Min Cheng
Wei-Chi WuWei-Chi Wu
Wei-Chi Wu
HCHung-Chi Chen
Hung-Chi Chen
Oxidative stress is an important pathomechanism found in numerous ocular degenerative diseases. To provide a better understanding of the mechanism and treatment of oxidant/antioxidant imbalance-induced ocular diseases, this article summarizes and provides updates on the relevant research. We review the oxidative damage (e.g., lipid peroxidation, DNA lesions, autophagy, and apoptosis) that occurs in different areas of the eye (e.g., cornea, anterior chamber, lens, retina, and optic nerve). We then introduce the antioxidant mechanisms present in the eye, as well as the ocular diseases that occur as a result of antioxidant imbalances (e.g., keratoconus, cataracts, age-related macular degeneration, and glaucoma), the relevant antioxidant biomarkers, and the potential of predictive diagnostics. Finally, we discuss natural antioxidant therapies for oxidative stress-related ocular diseases.

12 November 2020 in Bioengineering & Translational Medicine
Verified
Journal Article
Open access
PDF file
YTYu-Ting Tsao
Yu-Ting Tsao
Wei-Chi WuWei-Chi Wu
Wei-Chi Wu
KCKuan-Jen Chen
Kuan-Jen Chen
LYLung-Kun Yeh
Lung-Kun Yeh
YHYih‐Shiou Hwang
Yih‐Shiou Hwang
Chao-Min ChengChao-Min Cheng
Chao-Min Cheng
Corneal endothelial decompensation is a serious condition that frequently requires treatment via corneal transplantation which contributes to a global shortage in donor corneas. Therefore, the purpose of this study was to analyze the influence of aqueous humor total antioxidant capacity (TAC) on corneal endothelial health. There is an urgent need for discovering protective factors to combat corneal endothelial cell (CEC) loss. For methods, we developed a cupric ion‐based TAC (CuTAC) assay to analyze TAC level in a small volume of aqueous humor, that is, 10 μL per test, and examined the influences of ascorbic acid (AA) and antioxidant proteins on aqueous humor TAC. To broaden the investigation, we conducted a case–control study with patients classified into two groups, an insufficient endothelial cell density (ECD < 2100 cells/mm2) group, and a control group. These groups were formed based on baseline ECD values and were used to evaluate the influence of aqueous humor TAC and AA on overall corneal endothelial health. A CuTAC assay was used to accurately measure aqueous humor TAC without the need for sample dilution. After analyzing a total of 164 human aqueous humor samples, we found that AA was the major contributor to aqueous humor TAC (73.2%). In addition, TAC and AA levels in the IECD and control groups were both found to be significantly different (1.168 vs. 1.592 mM, p = 0.009 and 0.856 vs. 1.178 mM, p = 0.016). TAC and AA were considered independent protective factors against IECD with adjusted odds ratios of 0.02 (p = 0.017) and 0.023 (p = 0.033), respectively. In conclusion, aqueous humor TAC and AA contribute to the maintenance of sufficient corneal ECD, and our CuTAC assay can be a useful tool for analyzing TAC using only a small aqueous humor sample volume.

29 July 2020 in Bioengineering & Translational Medicine
Verified
Journal Article
Open access
PDF file
YTYu-Ting Tsao
Yu-Ting Tsao
CYChung-Yao Yang
Chung-Yao Yang
YWYun‐Chiao Wen
Yun‐Chiao Wen
TCTing‐Chang Chang
Ting‐Chang Chang
KMKoji Matsuura
Koji Matsuura
Chao-Min ChengChao-Min Cheng
Chao-Min Cheng
Male infertility affects millions of males worldwide and is rising in prevalence due to social and environmental conditions. However, men often feel too embarrassed to receive a semen analysis in the hospital due to social stigmas. To overcome this problem, we developed a 3‐(4,5‐Dimethyl‐2‐thiazolyl)‐2,5‐diphenyl‐2H‐tetrazolium bromide test strip to distinguish semen samples with low total motile sperm concentration from those with normal motile sperm concentration. This is a point‐of‐care colorimetric semen analytical method with a one‐step, inexpensive, equipment‐free evaluation process, and adequate accuracy validated in a 42‐sample clinical trial. In this study, results were evaluated visually and with a smartphone application. Using visual observation methods, the area under the curve (AUC) was 0.71 (95% of confidence interval = 0.55–0.86; p = 0.021), sensitivity was 41%, specificity was 95%, positive predictive value was 90%, negative predictive value (NPV) was 59.4%, and accuracy was 67%. Using a smartphone recording and analytical system, AUC was 0.766 (95% of confidence interval = 0.612–0.92; p = 0.003), sensitivity was 96%, specificity was 65%, PPV was 75%, NPV was 92.9%, and accuracy was 80.9%. This work demonstrated a screening tool that could elevate semen analysis to the level of routine healthcare and provide for private, in‐home self‐assessment.

16 February 2022 in Antioxidants
Verified
Journal Article
Open access
PDF file
YTYu-Ting Tsao
Yu-Ting Tsao
Wei-Chi WuWei-Chi Wu
Wei-Chi Wu
KCKuan-Jen Chen
Kuan-Jen Chen
CLChun-Fu Liu
Chun-Fu Liu
YHYi-Jen Hsueh
Yi-Jen Hsueh
HCHung-Chi Chen
Hung-Chi Chen
Cataract is the leading cause of blindness throughout the world. Currently, the cataract severity evaluation is based on the subjective LOCS III guideline. To ameliorate the evaluation system and develop an objective and quantitative analysis, we investigated the relationships among aqueous humor total antioxidant capacity (AqTAC), ascorbic acid (AqAA) concentration, and cataract severity. In this study, we enrolled 130 cataract patients who underwent phacoemulsification between April 2019 and March 2020. The AqTAC and AqAA were measured by our own developed TAC assay and commercially available kit. Cataract severity was recorded by nuclear opalescence (NO) and cortical cataract (CC) degree according to LOCS III. Cumulative dissipated energy (CDE) during phacoemulsification was recorded to verify the severity of the cataract. As a result, we found a moderate correlation between AqTAC and CDE (p < 0.001). In addition, we found AqTAC independently associated with the CDE when analyzed by multivariate linear regression (p < 0.001). AqTAC also negatively correlated to cataract severity when measured by NO and CC (p = 0.012 in NO grade 3 vs. grade 1; p = 0.012 in CC grade 2 vs. grade 1; p < 0.001 in CC grade 3 vs. grade 1). We further found AqAA provided 71.9 ± 13.5% of AqTAC, and showed a high correlation (rho = 0.79, p < 0.001). In conclusion, we found a significant correlation between AqTAC/AqAA and cataract severity measured by CDE. The correlation was superior to the correlation between LOCS III and CDE. Aqueous humor TAC owns the potential to assess cataracts in an objective and quantitative way.

10 August 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
WSWei-Hsuan Sung
Wei-Hsuan Sung
CLChing-Yi Liu
Ching-Yi Liu
CYChung-Yao Yang
Chung-Yao Yang
CCCheng-Han Chen
Cheng-Han Chen
YTYu-Ting Tsao
Yu-Ting Tsao
Chao-Min ChengChao-Min Cheng
Chao-Min Cheng
Urinary tract infections (UTI), one of the most common bacterial infections, annually affect 150 million people worldwide. Infants and the elderly are likely to have missed or delayed diagnosis of UTI due to difficulty clearly describing their symptoms. A rapid screening method for UTI is a critical and urgent need for these populations. The aim of our study is to develop a diaper-based testing device to assay urine biomarkers including pH, leukocyte, and nitrite level. This all-in-one device assists in urine collection and testing using a colorimetric approach to provide easily read visual results on the outside surface of a test strip-integrated diaper. In this study, we tested samples from 46 patients using testing strips and examined the results from 7 patients recruited to validate the strip-integrated diaper. In conclusion, this new diaper-based testing device is easy to use, rapid, and inexpensive, all of which imbue it with tremendous potential for development into a commercially viable UTI screening system.

27 December 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
CCCheng-Han Chen
Cheng-Han Chen
YTYu-Ting Tsao
Yu-Ting Tsao
PYPo-Ting Yeh
Po-Ting Yeh
YLYu-Hsiang Liao
Yu-Hsiang Liao
YLYi-Tzu Lee
Yi-Tzu Lee
Chao-Min ChengChao-Min Cheng
Chao-Min Cheng
Early detection of microorganisms is essential for the management of infectious diseases. However, this is challenging, as traditional culture methods are labor-intensive and time-consuming. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide-phenazine methosulfate (MTT-PMS) assay has been used to evaluate the metabolic activity in live cells and can thus be used for detecting living microorganisms. With the addition of NaOH and Tris-EDTA, the same approach can be accelerated (within 15 min) and used for the quick detection of common bacterial pathogens. The assay results can be evaluated colorimetrically or semi-quantitatively. Here, the quick detection by MTT-PMS assay was further investigated. The assay had a detection limit of approximately 104 CFU/mL. In clinical evaluations, we used the MTT-PMS assay to detect clinical samples and bacteriuria (>105 CFU/mL). The negative predictive value of the MTT-PMS assay for determining bacteriuria was 79.59% but was 100% when the interference of abnormal blood was excluded. Thus, the MTT-PMS assay might be a potential “rule-out” tool for bacterial detection in clinical samples, at a cost of approximately USD 1 per test. Owing to its low cost, rapid results, and easy-to-use characteristics, the MTT-PMS assay may be a potential tool for microorganism detection.