Taichi Shibuya

Mr. Taichi Shibuya


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2025 in Acoustics
Verified
Journal Article
Open access
PDF file
MCMuhammad Anshari Caronge
Muhammad Anshari Caronge
TSTaichi Shibuya
Taichi Shibuya
YAYasuhiro Arai
Yasuhiro Arai
XDXinyi Dong
Xinyi Dong
TKTakaharu Kunizane
Takaharu Kunizane
小明小泉 明
小泉 明
This study aimed to assess and improve the accuracy of a water leakage detection model proposed in preliminary research. The poor results for water leakage sound (recall) and background noise (specificity) were clarified using countermeasures in accordance with each condition. Additionally, frequency amplification in the range of 500–600 Hz, the attenuation of weak components, and a band-stop filter were used to remove the 50 Hz component and harmonics. Pre-processing was carried out in the form of amplification, with weak noise removed using a band-stop filter. The results showed that the application of the proposed model improved the detection accuracy by 80% at the observation points that initially had poor accuracy. Thus, the proposed method was effective at improving the performance of the Recurrence Plot-Convolutional Neural Network (RP-CNN) model for detecting water leakages.

14 November 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
MCMuhammad Anshari Caronge
Muhammad Anshari Caronge
TSTaichi Shibuya
Taichi Shibuya
YAYasuhiro Arai
Yasuhiro Arai
XDXinyi Dong
Xinyi Dong
TKTakaharu Kunizane
Takaharu Kunizane
小明小泉 明
小泉 明
This research aims to determine and improve accuracy of a water leakage detection model proposed in preliminary research. The poor results for water leakage sound (recall) and background noise (specificity) were clarified using countermeasures in accordance with each condition. Additionally, frequency amplification in the range of 500–600 Hz, attenuation of weak components, and a band-stop filter were used to remove the 50 Hz component and harmonics. Pre-processing was carried out in the form of amplification with weak noise removed using a band-stop filter. The results showed that application of the proposed model improved detection accuracy by 80% at observation points that initially had poor accuracy. Thus, the proposed method was effective in improving performance of the RP-CNN model in detecting leakage.

14 November 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
MCMuhammad Anshari Caronge
Muhammad Anshari Caronge
TSTaichi Shibuya
Taichi Shibuya
YAYasuhiro Arai
Yasuhiro Arai
XDXinyi Dong
Xinyi Dong
TKTakaharu Kunizane
Takaharu Kunizane
小明小泉 明
小泉 明
This research aims to determine and improve accuracy of a water leakage detection model proposed in preliminary research. The poor results for water leakage sound (recall) and background noise (specificity) were clarified using countermeasures in accordance with each condition. Additionally, frequency amplification in the range of 500–600 Hz, attenuation of weak components, and a band-stop filter were used to remove the 50 Hz component and harmonics. Pre-processing was carried out in the form of amplification with weak noise removed using a band-stop filter. The results showed that application of the proposed model improved detection accuracy by 80% at observation points that initially had poor accuracy. Thus, the proposed method was effective in improving performance of the RP-CNN model in detecting leakage.