Iuliia Azatovna Sadykova

Ms. Iuliia Azatovna Sadykova

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
ADAlexey Drobyshev
Alexey Drobyshev
ZGZaira M. Gurganchova
Zaira M. Gurganchova
NRNikolay Redko
Nikolay Redko
AKAlexander Komissarov
Alexander Komissarov
VBViacheslav Bazhenov
Viacheslav Bazhenov
OYOleg Yanushevich
Oleg Yanushevich
In the present study, pins made from the novel Mg-2Zn-2Ga alloy were installed within the femoral bones of six Wistar rats. The level of bioresorption was assessed after 1, 3, and 6 months by radiography, histology, SEM, and EDX. Significant bioresorption was evident after 3 months, and complete dissolution of the pins occurred at 6 months after the installation. No pronounced gas cavities could be found at the pin installation sites throughout the postoperative period. The animals’ blood parameters showed no signs of inflammation or toxication. These findings are sufficiently encouraging to motivate further research to broaden the experimental coverage to increase the number of observed animals and to conduct tests involving other, larger animals.

27 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
ADAlexey Drobyshev
Alexey Drobyshev
AKAlexander Komissarov
Alexander Komissarov
NRNikolay Redko
Nikolay Redko
ZGZaira M. Gurganchova
Zaira M. Gurganchova
Eugene StatnikEugene Statnik
Eugene Statnik
OYOleg Yanushevich
Oleg Yanushevich
The development direction of bioresorbable fixing structures is currently very relevant because it corresponds to the priority areas in worldwide biotechnology development. Magnesium (Mg)-based alloys are gaining high levels of attention due to their promising potential use as the basis for fixating structures. These alloys can be an alternative to non-degradable metal implants in orthopedics, maxillofacial surgery, neurosurgery, and veterinary medicine. In our study, we formulated a Mg-2Zn-2Ga alloy, prepared pins, and analyzed their biodegradation level based on SEM (scanning electron microscopy) and EDX (energy-dispersive X-ray analysis) after carrying out an experimental study on rats. We assessed the resorption parameters 1, 3, and 6 months after surgery. In general, the biodegradation process was characterized by the systematic development of newly formed bone tissue. Our results showed that Mg-2Zn-2Ga magnesium alloys are suitable for clinical applications.

28 December 2023 in Results in Materials
Verified
Journal Article
Open access
SRS. O. Rogachev
S. O. Rogachev
VBViacheslav Bazhenov
Viacheslav Bazhenov
AKAlexander A. Komissarov
Alexander A. Komissarov
DTDenis V. Ten
Denis V. Ten
ALAnna Li
Anna Li
ADAlexey Yu. Drobyshev
Alexey Yu. Drobyshev

12 November 2024 in Polymer
Verified
Journal Article
Closed access
PZPolina Zhukova
Polina Zhukova
IBInna Bulygina
Inna Bulygina
AZAnna Zimina
Anna Zimina
Eugene StatnikEugene Statnik
Eugene Statnik
EIEkaterina Ivantsova
Ekaterina Ivantsova
FSFedor Senatov
Fedor Senatov

9 September 2025 in Fracture and Structural Integrity
Verified
Journal Article
Open access
PDF file
KHKamal Hammad
Kamal Hammad
ISIuliia Azatovna Sadykova
Iuliia Azatovna Sadykova
EPEugene N. Prokopev
Eugene N. Prokopev
GTGalina V. Tyurina
Galina V. Tyurina
SISemen Ignatyev
Semen Ignatyev
Eugene StatnikEugene Statnik
Eugene Statnik
This study investigates spall damage and failure in Carbon Fiber-Reinforced Polymer (CFRP) pressure vessels under explosive internal loading using stimulated electric discharge. Analytical modeling, validation with published experimental data, and explicit numerical simulations were employed. A Coupled Eulerian–Lagrangian (CEL) framework in Abaqus/Explicit captured the dynamic-impact shock propagation, using continuum shell (SC8R) elements for the vessel, solid (C3D8R) for the PMMA insert, and Eulerian (EC3D8R) for copper-wire vapor. Intralaminar failure was modeled using the Hashin criterion, while interlaminar damage was captured using the energy-release-rate-tuned Virtual Crack Closure Technique (VCCT). Results demonstrated high-accuracy agreement with experiments in terms of free surface velocity and failure stresses, with minor discrepancies attributed to wire alignment, material model limitations, and wave reverberations. These findings highlight the reliability of the integrated modeling framework and support improved design and risk-mitigation strategies for composite pressure vessels, advancing safety and cost-efficiency through refined material characterization and structural assessment.

15 September 2026 in Measurement
Verified
Journal Article
Closed access
IZIgor A. Zorin
Igor A. Zorin
KKKonstantin S. Korobov
Konstantin S. Korobov
AFAlexander A. Frantsuzov
Alexander A. Frantsuzov
ASAndrey I. Shtypel
Andrey I. Shtypel
ISIuliia Azatovna Sadykova
Iuliia Azatovna Sadykova
Alexander KorsunskyAlexander Korsunsky
Alexander Korsunsky